• 제목/요약/키워드: Stage equipment

검색결과 608건 처리시간 0.022초

에어챔버 설치에 따른 펌프관로계의 수격현상 (Water-hammer in the Pump Pipeline System with and without an Air-Chamber)

  • 이선곤;양철수
    • 한국안전학회지
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

AHP 분석을 이용한 기계식 주차설비 건설 중 위험성 평가방안 연구 (Risk Assessment of Mechanical Parking Facility during Construction based on AHP Analysis)

  • 이정한;김용곤;이재원;김종훈
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.33-41
    • /
    • 2022
  • As the number of automobile registrations increases yearly, parking spaces that are located in downtown areas are increasing, and mechanical parking facilities are also increasing. Therefore, there is a high risk of accidents when installing and repairing a mechanical parking facility. In the preceding six years (from 2012 to 2018), the statistics that pertain to accidental disasters indicated that a total of 137 disaster victims were generated by the construction sector, 33 accidents occurred, and 10 people died. However, only the safety management items pertaining to accidents that occur during maintenance work and the use of the installed mechanical parking facilities are being studied; furthermore, there is no ongoing research with respect to the risk management that is conducted at the construction site. In 2017, the Korea Occupational Safety and Health Agency (KOSHA) announced the "Guidelines for Safe Installation and Maintenance of Mechanical Parking Equipment"; however, it is a safety guideline that is limited to the installation of basic protective equipment and to facility installation. There is no model for mechanical parking facilities that is indicated in the "Risk Assessment Model by Construction Industry Type", which is issued by the Safety and Health Corporation and is widely utilized for risk assessment in the construction industry; moreover, elevator installation work CODE N0: 22 is the only major example of a disaster. In this study, "risk assessment through a focus group interview" was performed, and data was derived from the "risk assessment of Article 41 (2) of the Industrial Safety and Health Act", which reflects the characteristics of the construction industry based on AHP analysis. The results of this study can be utilized for the risk assessment that is conducted during the construction stage of mechanical parking facilities.

고주파 LC 공진을 위한 병렬전극 전도냉각 필름커패시터의 파라메타 특성 분석 (Analysis of Parameter Characteristic of Parallel Electrodes Conduction-cooled Film Capacitor for HF-LC Resonance)

  • 원서연;이경진;김희식
    • 전자공학회논문지
    • /
    • 제53권6호
    • /
    • pp.155-166
    • /
    • 2016
  • 전자유도 가열시설에서 정밀하고 일정한 주파수 성분에 의해 가열물체에 발열을 유도하려면 LC공진회로 설계단계에서 출력 주파수에 대한 커패시터의 정전용량(C)과 워크코일의 유도계수(L) 설정이 중요하다. 하지만 고유의 발열계수를 가진 물체의 가열위치와 범위에 직접유도를 하는 워크코일은 고정적으로 설계되는 반면 커패시터는 가변되도록 설계되어야만 전체장비의 활용도가 높아진다. 본 논문에서는 $1000V_{MAX}$ 최대전압과 $200I_{MAX}$ 전류에서 최대 700kHz의 고주파 LC공진 출력이 되도록 커패시터 내부구성 원자재 선정 및 공정설계 단계까지 단일전극 용량별 샘플을 추출하였다. 그리고 정전용량 규격변화에 따라 주파수 변화특성과 출력 파라메타 결과를 바탕으로 HF-LC공진용 전도냉각 커패시터의 최적설계를 위한 관계를 증명하는 기초 실험결과를 제시하였다.

Identification and Multivariable Iterative Learning Control of an RTP Process for Maximum Uniformity of Wafer Temperature

  • Cho, Moon-Ki;Lee, Yong-Hee;Joo, Sang-Rae;Lee, Kwang-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2606-2611
    • /
    • 2003
  • Comprehensive study on the control system design for a RTP process has been conducted. The purpose of the control system is to maintain maximum temperature uniformity across the silicon wafer achieving precise tracking for various reference trajectories. The study has been carried out in two stages: thermal balance modeling on the basis of a semi-empirical radiation model, and optimal iterative learning controller design on the basis of a linear state space model. First, we found through steady state radiation modeling that the fourth power of wafer temperatures, lamp powers, and the fourth power of chamber wall temperature are related by an emissivity-independent linear equation. Next, for control of the MIMO system, a state space modeland LQG-based two-stage batch control technique was derived and employed to reduce the heavy computational demand in the original two-stage batch control technique. By accommodating the first result, a linear state space model for the controller design was identified between the lamp powers and the fourth power of wafer temperatures as inputs and outputs, respectively. The control system was applied to an experimental RTP equipment. As a consequence, great uniformity improvement could be attained over the entire time horizon compared to the original multi-loop PID control. In addition, controller implementation was standardized and facilitated by completely eliminating the tedious and lengthy control tuning trial.

  • PDF

양방향 3단 IMV 개발을 위한 시뮬레이션 해석 (Simulation Analysis for the Development of 3 Stage IMV)

  • 허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권2호
    • /
    • pp.55-62
    • /
    • 2020
  • There are two types of IMV for MCV, the spool type and the poppet type. The spool type is used in the existing excavator MCV and easily meets large-capacity flow conditions, but has a flow force problem which affects the spool control. The poppet type stably blocks the flow and has excellent rapid response. However, the larger the capacity, the larger the diameter of the poppet needed, requiring a strong spring to withstand the oil pressure. In this study, a bi-directional three-stage IMV for MCV that can be used in medium and large hydraulic excavators was proposed. This is a poppet type, enabling bi-directional flow control and resolves the problem of proportional solenoid suction force limitation. To investigate the validity of the proposed valve, the system was mathematically modeled and the static and dynamic characteristics were investigated through the simulation using commercial software. It has been concluded that the reverse flow is possible in a regeneration circuit and that the proposed IMV can be used to perform various excavation modes.

Application of Biofilter Using Fibril-form Matrix for Odor Gas Removal

  • Lee, Gwang-Yeon;Jeong, Gwi-Taek;Lee, Kyoung-Min;Snuwoo, Chang-Shin;Lee, Woo-Tae;Cha, Jin-Myoung;Jang, Young-Seon;Park, Don-Hee
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVI)
    • /
    • pp.247-251
    • /
    • 2005
  • This research was performed for developing of biological treatment process of odor gas such as MEK, $H_{2}S$, and toluene, which is generated from the food waste recycling process. To establish the operational conditions of odor gas removal by small-scale biofiltration equipment, it was continuously operated by using toluene as a treating odor object. When the odor treating microorganisms were adhered to fibril form biofilter, high removal efficiency over 93% was obtained by biofilm formation. At 400 ppm of inlet odor gas concentration and 10 sec of retention time, the removal efficiency was 76% and 93% in 1st stage reactor and 2nd stage reactor, respectively. However, the removal efficiency remained over 97% at the operational conditions above 15 sec of retention time.

  • PDF

매립지반 지하공동구의 수평이동원인에 대한 수치해석적 분석 (Numerical Analysis of Utility Tunnel Movement under Reclamation Ground)

  • 윤우현;황철성
    • 한국안전학회지
    • /
    • 제28권5호
    • /
    • pp.35-40
    • /
    • 2013
  • Recently reclamation land is largely developed to utilize the land according to economic growth. The soil of landfill is soft, low shear strength, which makes it difficult to use the equipment. A large movement is occurred on the utility tunnel under construction. The inclined land with high water level and underground facilities are widely distributed and the excess pore water pressure may occur under construction similarly to this study. Some different conditions are made to design result, such as 4m of soil piling near the construction area, heavy rainfall during 2nd excavation that may cause flow liquefaction. To analyze the cause of transverse lateral movement, Three dimensional analysis are performed to four load cases, which is original design condition, flow liquefaction by heavy rainfall, unsymmetric lateral soil pressure, and both of them simultaneously. Ten steps of full construction stage, 1st excavation for utility tunnel, construction of utility tunnel, 1st refill, piling soil from 1m to 4 m, 2nd excavation for drainage culvert, liquefaction around the utility tunnel, construction of drainage culvert and 2nd refill, are take into account to investigate the cause of movement.

Test Rig 동특성 분석에 따른 밸런싱 기술 적용 (Balancing Technic Based on Rotor Dynamics Analysis of Test Rig)

  • 황덕영;정천우;박인선;신동민;송진석
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.204-212
    • /
    • 2017
  • The rotor dynamics and balancing technic for rotating equipment during engineering and manufacture stage are to be carefully considered in order to minimize the operation troubles regarding vibration during commissioning stage. In this paper, the test rig, which includes the disks as balancing plane, is designed and manufactured, so that the characteristic of rotor dynamics can be analyzed such as critical speed and mode shape. The critical speed predicted through natural frequency analysis is verified by the actual measurement on bearing housing vibration during start-up condition of test rig. The low speed balancing and the operating speed balancing test are performed respectively with consideration of first critical speed, and the residual unbalance amounts are estimated in accordance with the relevant method described in API standard. In addition, the single and dual plane balancing are carried out on main disk and trim disk depended on phase information at each balancing step.

저가형 무인비행체를 활용한 정사영상 정확도 향상에 관한 연구 (A Study on the Accuracy Improvement of Orthophoto using Low-Cost UAV)

  • 윤부열
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.209-218
    • /
    • 2020
  • Various studies and business investments have been performed on UAV in the field of spatial information industry, and it is judged that this industry has being evolved into an expansion stage as a legalization progresses. In addition, public institutions such as Korea Land and Geospatial Information Corporation, Korea Expressway Corporation, and Korea Land and Housing Corporation which have relatively much utilized spatial information work have entered into the stage of settling with active introduction for reasons of work efficiency and business management. However, surveying drones are still classified as expensive equipment, which is a burden on general business application and technology popularization. Moreover, the stabilization of reliability of various location information acquired from UAV is a part of ongoing research and supplementation. Therefore, in this study, to use image information acquired from low-cost UAV as reliable spatial information data, the flight altitude was changed and compared with the result of double transverse flight with conventional photographing technique. As a result, there was no change in the result value at low altitude, but the result showed more than 30% accuracy and accuracy improvement for the X, Y value at the altitude of 130m or higher than the conventional method.

서비스품질지수를 고려한 품질기능전개를 통한 철도 서비스 품질 개선에 관한 연구 (A Study on Railway Services Improvement Using Quality Function Development Incorporating SERVPERF)

  • 고결;박경수;김재희
    • 품질경영학회지
    • /
    • 제44권2호
    • /
    • pp.451-466
    • /
    • 2016
  • Purpose: This study was to identify customers' demands in railway services system and then to seek the way to satisfy the customer expectations. Methods: We suggest a Quality Function Deployment(QFD)-based approach comprised of three stages. In first stage, SERVPERF survey was carried out to assess current positions of customer expectations in the market. Then, factor analysis was incorporated into SERVPERF to classify customer expectations for the house of quality. In the second stage, the analytic network process was used to prioritize the importance of the customer attributes. Finally, QFD was performed utilizing customer attributes and their weights. Results: The QFD identified the most important customer expectations as: accident prevention, swift reaction to accident, on-time arrivals and departures of the train. It also shows that driving capability, equipment for safety, and training for disaster are the most critical technical requirements. Conclusion: The results are useful for identifying the customers' demands in railway services systems, and they can contribute to the service quality and customer satisfaction.