• Title/Summary/Keyword: Stacking cone

Search Result 5, Processing Time 0.024 seconds

Development of Teleoperation System of rRclaimers (불출기의 원격운전 시스템 개발)

  • 신기태;최진태;이관희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1465-1468
    • /
    • 1996
  • In this paper, we suggest tele operation system of reclaimers and some side technologies for performing easy operation. The reclaimers in the raw ore yard are being used to dig ironstone and transfer it to the blast furnaces. The side technologies are to determine the minimum stacking distance between piles, collision avoidance of reclaimers and stackers. For simplicity, the pile and the boom of the reclaimer are mathematically modeled as a cone and a line in the 3-dimensional space respectively. The minimum stacking distance is obtained using the condition that the cone and the line never met. The modeling errors for the pile and reclaimers are compensated by considering the width of their reclaimer. We have also proposed a 2-stage collision detection method for the moving machines. The reclaiming heights of the pile are set to predetermined ones to make tele-operation easy.

  • PDF

Development and Usability Test of the Prototype of the "Smart Stacking Cone" Based on Dual-task Using ICT (ICT를 이용한 이중과제 기반의 스마트 스태킹 콘의 시제품 개발 및 사용성 평가)

  • Lim, Seung-Ju;Won, Kyung-A;Kim, Dae-Gyeom;Kim, Young;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.95-108
    • /
    • 2021
  • Objective : This study aimed to develop prototypes of "smart stacking cones" by combining ICT to evaluate and train the upper extremity function and dual task performance in patients with central nervous system impairment, and to identify the complementary point to the completion of the device through a usability test. Methods : This prototype comprised of a hardware and software system that enabled the evaluation and training of patients and the management of data obtained from patients' performance. Specific measurement variables were established so that patient performance could be measured correctly. Based on the measurement variables, a the prototype included a 'single task evaluation modes', 'dual task evaluation mode', 'single task training mode', and 'dual task training modes'. Additionally, a usability test was conducted to assess clinical applicability and overall satisfaction for the prototype. Results : The results of the usability test were generally found to be appropriate. The 'content adequacy' in the usability test was the area with the highest level of adequacy and the lowest level of inadequacy. Additionally, overall 'satisfaction' in the usability test was the area with the highest appropriate and inappropriate levels. Hence, the overall satisfaction results were unstable. Conclusion : Future studies should be conducted to identify the clinical effectiveness of the device by applying an upgraded smart stacking cone to an actual patient group.

Ellipse-Stacking Methods for Image Reconstruction in Compton Cameras (컴프턴 카메라 영상재구성을 위한 타원 누적법)

  • Lee, Mi-No;Lee, Soo-Jin;Kim, Soo-Mee;Lee, Jae-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.520-529
    • /
    • 2007
  • An efficient method for implementing image reconstruction algorithms for Compton cameras is presented. Since Compton scattering formula establishes a cone surface from which the incident photon must have originated, it is crucial to implement a computationally efficient cone-surface integration method for image reconstruction. In this paper we assume that a cone is made up of a series of ellipses (or circles) stacked up one on top of the other. In order to reduce computational burden for tracing ellipses formed by the intersection of a cone and an image plane, we propose a new method using a series of imaginary planes perpendicular to the cone axis so that each plane contains a circle, not an ellipse. In this case the cone surface integral can be performed by simply accumulating the circles along the cone axis. To reduce the computational cost of tracing circles, only one of the circles in the cone is traced and the rest are determined by using simple trigonometric ratios. For our experiments, we used the three different schemes for tracing ellipses; (i) using the samples generated by the ellipse equation, (ii) using the fixed number of samples along a circle on the imaginary plane, and (iii) using the fixed sampling interval along a circle on the imaginary plane. We then compared performance of the above three methods by applying them to the two reconstruction algorithms - the simple back-projection method and the expectation-maximization algorithm. The experimental results demonstrate that our proposed methods (ii) and (iii) using imaginary planes significantly improve reconstruction accuracy as well as computational efficiency.

Vibration analysis of a shear deformed anti-symmetric angle-ply conical shells with varying sinusoidal thickness

  • Javed, Saira;Viswanathan, K.K.;Aziz, Z.A.;Lee, J.H.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.6
    • /
    • pp.1001-1020
    • /
    • 2016
  • The study is to investigate the free vibration of antisymmetric angle-ply conical shells having non-uniform sinusoidal thickness variation. The arbitrarily varying thickness is considered in the axial direction of the shell. The vibrational behavior of shear deformable conical shells is analyzed for three different support conditions. The coupled differential equations in terms displacement and rotational functions are obtained. These displacement and rotational functions are invariantly approximated using cubic spline. A generalized eigenvalue problem is obtained and solved numerically for an eigenfrequency parameter and an associated eigenvector of spline coefficients. The vibration characteristic of the shells is examined for cone angle, aspect ratio, sinusoidal thickness variation, layer number, stacking sequence, and boundary conditions.

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF