• Title/Summary/Keyword: Stack type

Search Result 294, Processing Time 0.027 seconds

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

Design and Self-sustainable Operation of 1 kW SOFC System (1kW 고체산화물 연료전지(SOFC) 시스템 설계 및 자열운전)

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung;Nam, Suk-Woo
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.5
    • /
    • pp.384-389
    • /
    • 2009
  • KEPRI (Korea Electric Power Research Institute) has studied planar type solid oxide fuel cell (SOFC) stacks using anode-supported cells and kW class co-generation systems for residential power generation. In this work, a 1 kW SOFC system consisted of a hot box part, a cold BOP (balance of plant) part, and a hot water reservoir. The hot box part contained a SOFC stack made up of 48 cells, a fuel reformer, a catalytic combustor, and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation in that system. A cold BOP part was composed of blowers, pumps, a water trap, and system control units. When the 1 kW SOFC stack was tested using hydrogen at $750^{\circ}C$, the stack power was about $1.2\;kW_e$ at 30 A and $1.6\;kW_e$ at 50 A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_e$ with hydrogen and $1.2\;kW_e$ with city gas respectively. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water.

Generalized LR Parser with Conditional Action Model(CAM) using Surface Phrasal Types (표층 구문 타입을 사용한 조건부 연산 모델의 일반화 LR 파서)

  • 곽용재;박소영;황영숙;정후중;이상주;임해창
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.1_2
    • /
    • pp.81-92
    • /
    • 2003
  • Generalized LR parsing is one of the enhanced LR parsing methods so that it overcome the limit of one-way linear stack of the traditional LR parser using graph-structured stack, and it has been playing an important role of a firm starting point to generate other variations for NL parsing equipped with various mechanisms. In this paper, we propose a conditional Action Model that can solve the problems of conventional probabilistic GLR methods. Previous probabilistic GLR parsers have used relatively limited contextual information for disambiguation due to the high complexity of internal GLR stack. Our proposed model uses Surface Phrasal Types representing the structural characteristics of the parse for its additional contextual information, so that more specified structural preferences can be reflected into the parser. Experimental results show that our GLR parser with the proposed Conditional Action Model outperforms the previous methods by about 6-7% without any lexical information, and our model can utilize the rich stack information for syntactic disambiguation of probabilistic LR parser.

A Study on the Safety of Carbon Manufacturing By-product Gas Emissions (카본제조 부생가스 배출 안전성에 관한 연구)

  • Joo, Jong-Yul;Jeong Phil-Hoon;Kim, Sang-Gil;Sung-Eun, Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

Position Control of Ultra-Precision Machine Tool Postusing Piezoelectric Material) (압전재료를 이용한 초정밀 가공기용 공구위치제어)

  • 김태형
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.28-33
    • /
    • 1996
  • This paper presents a position control of ultra-precision machine tool post using piezoelectric material. A stack-type piezoelectric actuator is employed in a hinge-type tool holder. An assumed linear transfer function of the practical nonlinear plant is established through the comparison of transfer functions and step responses in the experiments and the simulations. Several types of feedforward/feedback controllers are designed via computer simulations using the assumed linear transfer function, The position tracking control experiments are undertaken to show the control efficiency of each controller.

  • PDF

Automated Test Data Generation for Testing Programs with Multi-level Stack-directed Pointers (다단계 스택 지향 포인터가 있는 프로그램 테스트를 위한 테스트 데이터 자동 생성)

  • Chung, In-Sang
    • The KIPS Transactions:PartD
    • /
    • v.17D no.4
    • /
    • pp.297-310
    • /
    • 2010
  • Recently, a new testing technique called concolic testing receives lots of attention. Concolic testing generates test data by combining concrete program execution and symbolic execution to achieve high test coverage. CREST is a representative open-source test tool implementing concolic testing. Currently, however, CREST only deals with integer type as input. This paper presents a new rule for automated test data generation in presence of inputs of pointer type. The rules effectively handles multi-level stack-directed pointers that are mainly used in C programs. In addition, we describe a tool named vCREST implementing the proposed rules together with the results of applying the tool to some C programs.

Effects of Key Operating Parameters on the Efficiency of Two Types of PEM Fuel Cell Systems (High-Pressure and Low-Pressure Operating) for Automotive Applications

  • Kim Han-Sang;Lee Dong-Hun;Min Kyoungdoug;Kim Minsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1018-1026
    • /
    • 2005
  • The proton exchange membrane (PEM) fuel cell system consisting of stack and balance of plant (BOP) was modeled in a MATLAB/Simulink environment. High-pressure operating (compressor type) and low-pressure operating (air blower type) fuel cell systems were con­sidered. The effects of two main operating parameters (humidity and the pressure of the supplied gas) on the power distribution characteristics of BOP and the net system efficiency of the two systems mentioned above were compared and discussed. The simulation determines an optimum condition regarding parameters such as the cathode air pressure and the relative humidity for maximum net system efficiency for the operating fuel cell systems. This study contributes to get a basic insight into the fuel cell stack and BOP component sizing. Further research using muli­object variable optimization packages and the approach developed by this study can effectively contribute to an operating strategy for the practical use of fuel cell systems for vehicles.

Fabrication and Performance Test in Stacks up to 1kW Planar Solid Oxide Fuel Cell (1kW 평판형 SOFC 스택제작 및 성능평가)

  • Cho, Nam-Ung;Hwang, Soon-Cheoi;Han, Sang-Moo;Kim, Yeong-Woo;Kim, Seung-Goo;Jun, Jae-Ho;Kim, Do-Hyeong;Jun, Joong-Hwan
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.5-13
    • /
    • 2007
  • Stacks of solid oxide fuel cell with 1kW max power performance were designed on planar type employing anode-supported cells and metallic interconnects. The stacks composed of 3-cells, 8-cells, and 16-cells were fabricated and tested in serials by using anode-supported cells purchased from Indec, and sealants/interconnects prepared at RIST. In the performance test of the final 16-cells stack, OCV was recorded to be 16.7V. The peak power and the power density showed 1 kW, $0.77W/cm^2$ at $820^{\circ}C$, respectively. In addition, the long-term degradation rate of the power exhibited 2.25 % during 500h at $750^{\circ}C$.

  • PDF