• Title/Summary/Keyword: Stability of course

Search Result 218, Processing Time 0.027 seconds

Change of Temperament and Personality in Post-traumatic Stress Disorders (외상후 스트레스장애에서 기질 및 성격의 변화)

  • Choi, Hyosun;Kim, Daeho;Kim, Eunkyeong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.28 no.2
    • /
    • pp.155-160
    • /
    • 2020
  • Objectives : This study investigate to identify the stability of temperament and personality characteristics of patients including Posttraumatic Stress Disorder (PTSD) patients. Methods : The number of subjects was 102, of which 33 were PTSD patients and 69 were non-PTSD patients. To demonstrate the change in individual temperament and personality characteristics, Temperament and Character Inventory (TCI) were administered repeatedly on the subjects. Repeated measures ANOVA and simple main effects analysis were conducted. Results : When analysed by dividing the subjects into PTSD groups and non-PTSD groups, the differences between the primary and secondary tests did not appear in the non-PTSD groups, but the differences between the primary and secondary tests were significant in Harm Avoidance (HA), Reward Dependence (RD), Self-Directedness (SD), Cooperativeness (C). In addition, it was noted that the time and group interaction effects of HA, RD, SD and C were significant, and that the main effects of time of HA, RD, SD and C were significant. Conclusions : This study is meaningful in that in the course of experience and recovery of traumatic events, we have clinically confirmed that changes in the temperament, known as stable variables, are possible.

A Study on Engineering Characteristics of Asphalt Concrete Mixtures Using Filler with Recycled Waste Lime (부산석회를 채움재로 재활용한 아스팔트 혼합물의 공학적 특성)

  • Hwang, Sung-Do;Park, Hee-Mun
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.71-78
    • /
    • 2005
  • This study focuses on finding out engineering characteristics of asphalt concrete mixtures using mineral fillers with recycled waste lime, which is a by-product in the Soda Ash(Na2CO3) production course. The materials tested in this study were made with 25%, 50%, 75% and 100% of mixing ratio based on the conventional mineral filler ratio to analyze the recycle possibility of the waste lime. The asphalt concrete mixtures with recycled waste lime and hydrated lime, and conventional asphalt concrete mixtures were evaluated through their fundamental engineering properties such as Marshall stability, indirect tensile strength, resilient modulus, permanent deformation characteristics, moisture susceptibility and fatigue resistance. The results indicate that the application of recycled waste lime as mineral filler improves the permanent deformation characteristics, stiffness and fatigue endurance of asphalt concrete mixtures at the wide range of temperatures. It is also found that the mixtures with recycled waste lime show higher resistance against stripping than conventional asphalt concrete mixtures. It is concluded from various test results that the waste lime can be used as mineral fillers and especially can greatly improve resistance to permanent deformation of asphalt concrete mixtures at high temperatures.

  • PDF

Derivation of Mohr Envelope of Hoek-Brown Failure Criterion Using Non-Dimensional Stress Transformation (응력무차원화 변환을 이용한 Hoek-Brown 파괴함수의 Mohr 파괴포락선 유도)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.24 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • In the course of performing the stability analysis of rock structures, there are times when the strength of the Hoek-Brown rock mass needs to be understood in terms of the internal friction angle and cohesion. In this case, the original Hoek-Brown criteion, giving the relationship between ${\sigma}_1$ and ${\sigma}_3$ at failure, have to be transformed to the corresponding Mohr envelope. A new approach to derive the Mohr envelope of the Hoek-Brown criterion is suggested in this study. The new method is based on the Londe's transformation making the stress components dimensionless. The correctness of the derivation leading to the new ${\tau}-{\sigma}$ relationship is confirmed by comparing the calculation results with the Bray's solution through a verification example.

Clinical Outcomes and Complications after Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance Patients : A Long-Term Follow-Up Data

  • Hyun, Seung-Jae;Rhim, Seung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.95-101
    • /
    • 2010
  • Objective : Clinical, radiographic, and outcomes assessments, focusing on complications, were performed in patients who underwent pedicle subtraction osteotomy (PSO) to assess correction effectiveness, fusion stability, procedural safety, neurological outcomes, complication rates, and overall patient outcomes. Methods : We analyzed data obtained from 13 consecutive PSO-treated patients presenting with fixed sagittal imbalances from 1999 to 2006. A single spine surgeon performed all operations. The median follow-up period was 73 months (range 41-114 months). Events during peri operative course and complications were closely monitored and carefully reviewed. Radiographs were obtained and measurements were done before surgery, immediately after surgery, and at the most recent follow-up examinations. Clinical outcomes were assessed using the Oswestry Disability Index and subjective satisfaction evaluation. Results : Following surgery, lumbar lordosis increased from $-14.1^{\circ}{\pm}20.5^{\circ}$ to $-46.3^{\circ}{\pm}12.8^{\circ}$ (p<0.0001). and the C7 plumb line improved from $115{\pm}43\;mm$ to $32{\pm}38\;mm$ (p<0.0001). There were 16 surgery-related complications in 8 patients; 3 intraoperative, 3 perioperative, and 10 late-onset postoperative. The prevalence of proximal junctional kyphosis (PJK) was 23% (3 of 13 patients). However, clinical outcomes were not adversely affected by PJK. Intraoperative blood loss averaged 2,984 mL. The C7 plumb line values and postoperative complications were closely correlated with clinical results. Conclusion : Intraoperative or postoperative complications are relatively common following PSO. Most late-onset complications in PSO patients were related to PJK and instrumentation failure. Correcting the C7 plumb line value with minimal operative complications seemed to lead to better clinical results.

Studies on Cellulase -Part 1. Isolation of Cellulase Forming Microorganisms and the Properties of Crude Enzymes- (Cellulase에 관(關)한 연구(硏究) -(제1보(第一報)) Cellulase 생성균(生成菌)의 분리(分離)와 조효소(粗酵素)의 제성질(諸性質)-)

  • Chung, Dong-Hyo
    • Applied Biological Chemistry
    • /
    • v.11
    • /
    • pp.109-117
    • /
    • 1969
  • Out of some 400 strains of Microorganisms, cellulase forming organisms was isolated from night soil during the course of screening tests. Two strains, Ku-3371 and Ku-4383 were found capable of producing cellulase in the shaking culture. General properties of the crude enzyme were as the following results. 1. The optimum pH values on CMC-saccharifying, CMC-liquefying and filter paper disintegrating activities were 4.0 to 5.5. 2. The stable pH range was within 3.5 to 6.5, 3. The optimum temperature was $40-45^{\circ}C$, the thermal stability was below $50^{\circ}C$ except on paper disintegrating activity and completely inactivated at $70^{\circ}C$. 4. Dialyzed crude enzyme was activated by $Mn^{2+}\;and\;Co^{2+}$ repectively but $Hg^{2+}$ was strong inhibitor.

  • PDF

A Design of a Personnel Control System Using UHF-RFID in Shipping (UHF 대역 RFID를 이용한 선박내 인원관리 시스템 설계)

  • Cha, Jin-Man;Kim, Myeung-Hwan;Park, Yeoun-Sik;Seong, Gil-Yeong;Lee, Sang-Uk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.832-835
    • /
    • 2008
  • An information-oriented basis in today's society has been changing fast, and the desire for connectivity has caused an exponential growth in wireless communication and sensor network. Sensor networks using RFID, in particular, have led this trend due to the increasing exchange of data in Ubiquitous such as the home RF, access control system, U-Healthcare, and Logistics information Systems. Also, the RFID when it applies a technique, is able to raise the stability of shipping as controling the mobile course and an entrance and exit of the crews an well as previously preventing an accident from shipping. In this paper, we designed and implemented personnel control system using UHF-RFID in vessels which shows through host PC reading and writing tag.

  • PDF

A Design of a Personnel Control System Using UHF-RFID in Shipping (UHF 대역 RFID를 이용한 선박내 인원관리 시스템 설계)

  • Cha, Jin-Man;Kim, Myeung-Hwan;Sung, Kil-Young;Lee, Sang-Wook;Park, Yeoun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2119-2124
    • /
    • 2008
  • An information-oriented basis in today's society has been changing fast, and the desire for connectivity has caused an exponential growth in wireless communication and sensor network. Sensor networks using RFID, in particular, have led this trend due to the increasing exchange of data in Ubiquitous such as the home RF, access control system, U-Healthcare, and Logistics information Systems. Also, the RFID when it applies a technique, is able to raise the stability of shipping as controling the mobile course and an entrance and exit of the crews an well as previously preventing an accident from shipping. In this paper, we designed and implemented personnel control system using UHF-RFID in vessels which shows through host PC reading and writing tag.

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF

MICROLEAKAGE AND WATER STABILITY OF RESIN CEMENTS

  • Choi Sun-Young;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.369-378
    • /
    • 2003
  • Statement of Problem: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. Purpose: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. Materials and Methods: 32 extracted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from $5^{\circ}C$ to $55^{\circ}C$ of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at ${\times}40$ magnification and a digital traveling micrometer with an accuracy of ${\pm}3{\mu}m$. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). Results : Statistically significant difference of microleakage was shown in the 3-month group compared with the1-day or 1-month group in both systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). Conclusion: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stability and the bonding durability of the resin cement. CLINICAL IMPLICATIONS Microleakage at the Cement-tooth interfaces did not necessarily result in the failure of the crowns. But it is considered to be a major factor influening the longerity of restorations. Further clinical approaches for decreasing the amount of microleakage are required.

Dynamic Morphologic Study of the Ulnar Nerve Around the Elbow Using Ultrasonography (초음파를 이용한 주관절 주위 척골 신경의 동적 형태학적 연구)

  • Jeon, In-Ho;Lee, Seong-Man;Choi, Jin-Won;Kim, Poong-Tak
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • Purpose: The morphological study and dynamic stability of the ulnar nerve around the elbow joint was investigated in asymptomatic normal population using ultrasonography. The purpose of this study is to provide fundamental data for ultrasonographic diagnosis of ulnar neuropathy in cubital tunnel syndrome. Materials and Methods: Fifty cases of 25 healthy male volunteers, aged between 20 to 30 years, included in this study. High resolution 7.5 MHz linear probe was used to examine the ulnar nerve in axial and longitudinal views. In a longitudinal view, the course, position and the thickness of nerve were monitored, the diameter of ulnar nerve and dynamic stability at elbow flexion and extension were measured in an axial view at four different points; 1cm proximal to medial epicondyle, behind the medial epicondyle, entrance to Osborne ligament, and 1cm distal to Osborne ligament. Results: The short diameters of ulnar nerve at elbow extension at four anatomic points were 2.66 mm, 2.97 mm, 2.64 mm, and 2.69 mm and the long diameters were 4.61 mm, 4.56 mm, 4.36 mm, and 4.37 mm, which showed no significant change at each point. However, at elbow flexion, the short diameters were changed to 2.72 mm, 2.34 mm, 2.65 mm, and 2.41 mm and the long diameters into 4.49 mm, 5.40 mm, 4.16 mm, and 4.66 mm. At elbow flexion, significant morphologic change was observed in the medial epicondyle area, and the diameter of the ulnar nerve was shortest at the entrance of Osborne ligament both at flexion and extension. In terms of dynamic stability, nine subluxations and seven dislocations were observed. Conclusion: This study shows dynamic instability and a morphological change of long and short diameters of ulnar nerve at flexion and extension in a normal person, which should be considered in the ultrasonographic diagnosis of ulnar neuropathy.