• 제목/요약/키워드: Stability check

검색결과 376건 처리시간 0.031초

콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가 (Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements)

  • 박성태;박준영;이재훈;김형배
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

지반특성에 기초한 모형 연성방호책 지주의 정적 및 동적안정성 평가 (Static and Dynamic Stability Evaluation of Model Guardrail Posts Based on Geotechnical Properties)

  • 임유진
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.233-245
    • /
    • 2009
  • 연성방호책 지주(post)의 설계 지반물성치를 파악하고 이를 이용한 해석방법을 수립하기 위한 방법으로서 공내재하시험(PMT)의 사용가능성을 검토하였다. 공내재하시험 결과를 이용하여 지주의 휨모멘트 및 하중-변위관계를 예측할 수 있는 해석방법의 수립가능성을 검토하였다. 모형지반과 모형지주를 이용한 정재하시험을 실시하여 하중-변위의 발생패턴과 크기를 분석하였으며 이를 공내재하시험 해석방법으로부터 구한 결과값과 비교하여 공내재하시험 해석방법의 타당성을 검토하였다. 또한 모형차(bogie)를 이용하여 모형 지주에 대한 충격시험을 실시하여 지주주변지반의 파괴형태를 파악하였으며 측정된 최대감가속도로부터 정적지지력 대비 동적지지력의 발생크기를 분석하였다. 이와 같은 시험 및 해석결과로부터 공내재하시험이 방호책 지주와 도로지반 사이의 역학적 상호연관성을 분석하기 위한 합리적인 시험방법이 될 수 있음을 확인하였다.

  • PDF

현호색(玄胡索).홍화(紅花).적작약(赤芍藥)이 관절염 흰쥐의 염증과 간(肝)에 미치는 영향 (Effect of Corydalidis Tuber.Carthami Flos.Paeoniae Radix Rubra on Anti-Inflamation and function of the Liver at Arthritis Rats)

  • 윤시진;김연섭
    • 동의생리병리학회지
    • /
    • 제19권2호
    • /
    • pp.475-480
    • /
    • 2005
  • This study is designed to find out the effect of Corydalidis Tuber Carthami Flos Paeoniae Radix Rubra mixed water extract on adjuvant arthritis, and to check the stability for Corydalidis Tuber Carthami Flos Paeoniae Radix Rubra mixed water extract about the liver. At first, rats were devided into four groups; Normal(Non-treated group with FCA), Control(Group administrated saline everyday for 1 week after treatment of FCA), Sample A(group administrated Corydalidis Tuber Paeoniae Radix Rubra Carthami Flos mixed water extract $9mg/200{\sim}220g$ everyday 1 week after treatment of FCA) and Sample B(Group administrated Corydalidis Tuber Paeoniae Radix Rubra Carthami Flos mixed water extract $18mg/200{\sim}220g$ everyday 1 week after treatment of FCA). After then, separated searches were made on the change of edema rate, the number of WBC, the contented quantities of total protein, total bilirubin, GOT, GPT in the serum. Result : In the right planter edema, both of Sample groups showed a decrease with statistical significance in comparison with control group. In the WBC count, Sample B group showed a decrease with statistical significance in comparison with control group and also sample A group showed a decrease, but did not show statistical significance. In the serum total protein, both of samples did not show statistically significant decrease in comparison with the control group. In the serum total bilirubin, GOT and GPT, both of samples did not show any harmful change about the liver in comparison with the control group. According to the above results, it is concluded that Corydalidis Tuber Paeoniae Radix Rubra Carthami Flos mixed water extract had the therapeutic effect of anti-inflammation in adjuvant arthritis with no injury to liver.

토피고 변화에 따른 Liner Plate 거동특성에 관한 연구 (A study on behavior characteristics of liner plate with depth)

  • 정지수;지영환;조현;허인영;이승호
    • 한국터널지하공간학회 논문집
    • /
    • 제14권2호
    • /
    • pp.131-139
    • /
    • 2012
  • 본 연구에서는 도심지 소구경 터널굴착공법에서 파형강판으로 제작된 liner plate의 거동특성에 대해 알아보기 위해 유한요소 해석 프로그램인 MIDAS/GTS를 이용하여 수치해석을 실시하였다. 토피고 변화에 따라 liner plate의 거동특성을 알아보기 위해 토피고는 5 m, 10 m, 15 m, 20 m, 25 m 5가지 각 조건으로 해석을 실시하였다. 수치해석결과 liner plate의 최대변위와 최대축응력은 부재의 하단부에서 발생되며, 최대전단응력의 경우 부재의 천단부에서 발생되는 것으로 확인되었다. 또한 토피고에 따른 liner plate의 변위, 응력, 전단응력의 변화는 있었으나 그 차이가 미미하고 토피고가 증가함에 따라 점점 구조적 안정성이 확보되는 것으로 판단된다.

Effects of hygro-thermo-mechanical conditions on the buckling of FG sandwich plates resting on elastic foundations

  • Refrafi, Salah;Bousahla, Abdelmoumen Anis;Bouhadra, Abdelhakim;Menasria, Abderrahmane;Bourada, Fouad;Tounsi, Abdeldjebbar;Bedia, E.A. Adda;Mahmoud, S.R.;Benrahou, Kouider Halim;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • 제25권4호
    • /
    • pp.311-325
    • /
    • 2020
  • In this research work, the hygrothermal and mechanical buckling responses of simply supported FG sandwich plate seated on Winkler-Pasternak elastic foundation are investigated using a novel shear deformation theory. The current model take into consideration the shear deformation effects and ensures the zero shear stresses on the free surfaces of the FG-sandwich plate without requiring the correction factors "Ks". The material properties of the faces sheets of the FG-sandwich plate are assumed varies as power law function "P-FGM" and the core is isotropic (purely ceramic). From the virtual work principle, the stability equations are deduced and resolved via Navier model. The hygrothermal effects are considered varies as a nonlinear, linear and uniform distribution across the thickness of the FG-sandwich plate. To check and confirm the accuracy of the current model, a several comparison has been made with other models found in the literature. The effects the temperature, moisture concentration, parameters of elastic foundation, side-to-thickness ratio, aspect ratio and the inhomogeneity parameter on the critical buckling of FG sandwich plates are also investigated.

은나노입자의 방사성 동위원소 운반체 적용 유효성 검증 연구 (Feasibility Study on Silver Nanoparticle Application to a Radioisotope Carrier)

  • 장범수;이주상;박해준;김화정;박상현
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.197-202
    • /
    • 2011
  • In this study, an Ag-polyaniline-silica (Ag-PANI-silica) nanoparticle was evaluated as a radioisotope carrier. An Ag-PANI-silica nanoparticle was incubated in the $^{125}I$ solution for a duration of 24 hr to test its radioisotope absorptivity. During the incubation, radioactivity of the nanoparticle was measured at 3, 6, 12, and 24 hr. After a 24 hr incubation, $^{125}I$-Ag-PANI-silica nanoparticle was incubated in a fresh saline for a duration of 48 hr to check its stability. Additionally, the $^{125}I$-Ag-PANI-silica nanoparticle was injected to the ICR mouse to investigate its in-vivo distribution characteristics. The $^{125}I$ absorption yield of the Ag-PANI-silica nanoparticle was higher than 95% after a 6 hr incubation period in the $^{125}I$ solution. And $^{125}I$-Ag-PANI-silica was stable for 48 hr at 80% yield at room temperature. The SPECT/CT image of a mouse that received $^{125}I$-Ag-PANI-silica complex showed that the $^{125}I$-Ag-PANI-silica complex was distributed in the lung, stomach and thyroid at 30 min post injection. From these results, the Ag-PANI-silica nanoparticle has good radio-iodine carrying property and can be applicable for the purpose of diagnosis and therapy.

A Study of Simple Sleep Apnea Predictive Device Using SpO2 and Acceleration Sensor

  • Woo, Seong-In;Lee, Merry;Yeom, Hojun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권4호
    • /
    • pp.71-75
    • /
    • 2019
  • Sleep apnea is a disease that causes various complications, and the polysomnography is expensive and difficult to measure. The purpose of this study is to develop an unrestricted wearable monitoring system so that patients can be examined in a familiar environment. We used a method to detect sleep apnea events and to determine sleep satisfaction by non-constrained method using SpO2 measurement sensor and 3-axis acceleration sensor. Heart rate and SpO2 were measured at the finger using max30100. After acquiring the SpO2 data of the user in real time, the apnea measurement algorithm was used to transmit the number of apnea events of the user to the mobile phone using Bluetooth (HC-06) on the wrist. Using the three-axis acceleration sensor (mpu6050) attached to the upper body, the number of times of tossing and turning during sleep was measured. Based on this data, this algorithm evaluates the patient's tossing and turning during sleep and transmits the data to the mobile phone via Bluetooth. The power source used 9 volts battery to operate Arduino UNO and sensors for portability and stability, and the data received from each sensor can be used to check the various degree between sleep apnea and sleep tossing and turning on the mobile phone. Through thisstudy, we have developed a wearable sleep apnea measurement system that can be easily used at home for the problem of low sleep efficiency of sleep apnea patients.

진동사용성을 고려한 철도교량구조물의 강성한계 분석 (Estimation of Stiffness Limit for Railway Bridge Vibration Serviceability)

  • 전법규;김남식;김성일
    • 한국철도학회논문집
    • /
    • 제11권5호
    • /
    • pp.489-498
    • /
    • 2008
  • 일반적으로 허용처짐 기준은 정적 사용성과 구조적안전성에 그 기반을 두고 있으며 진동사용성에 대한 고려는 부족하다. 따라서 진동사용성을 고려할 수 있는 교량의 허용처짐 기준이 필요하다고 판단된다. 본 논문에서는, 한국철도교설계기준의 허용처짐기준을 주파수영역의 진동사용성 기준과 비교하였으며, 프랑스 및 일본의 철도교설계기준의 진동사용성 허용기준 또한 분석하였다. 그 결과, 한국철도교설계기준의 경우 열차의 속도에 따른 기준으로 진동지속시간이 부분적으로 고려되었지만 진동사용성은 만족하지 못하고 있는 것으로 판단되었으며, 국외 철도교설계기준비 분석결과, 진동사용성을 고려한 허용처짐기준을 제시할 수 있을 것으로 판단하였다. 공용중인 철도교량의 진동사용성을 평가하기위하여 다양한 형식의 철도교량의 진동신호를 측정하였다. 그리고, 현장에서 적용하기 편리한 진동사용성 처짐 및 강성한계를 제시하기 위하여 공용중인 교량을 대상으로 차량 교량 상호작용해석을 수행하였다.

무인 원격 방사선 검출 모듈 개발 (Development of Unmanned Remote Radiation Detection Module)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.795-801
    • /
    • 2021
  • 원전 해체 작업장의 요구에 따라 드론 기반 무인 원격 방사선 검출 모듈을 개발하였다. 사람이 접근해서 방사선을 측정할 수 없는 원자력 발전소 격납용기 내부 상공 및 외부로 누설되는 방사선 측정을 위한 목적으로 저준위에 민감한 GM-tube를 사용하여 제작하였다. 드론 기반 방사선 검출 모듈의 무게는 200g 미만으로 원자력 발전소 격납용기 내부의 상공과 외부 공중에서도 운용이 가능하다. 설계된 장비의 성능 확인을 위해 국제 기준 (IEC60864)을 참고하여 성능평가 실험을 시행하였다. 현장의 요구에 맞게 설계된 방사선 검출 모듈의 안정성은 측정 정확도를 평가하기 위한 변동률 실험에서 반복 측정에 의한 통계적 변동률은 ±4.6%. 선량률 의존성을 평가하기 위한 선형성 실험에서 정확도 ± 7.3%, 전체 선형도는 ± 3.5%이며 성능평가를 위한 국제기준을 만족하였다. 본 연구에서 개발한 무인 원격 방사선 검출 모듈은 원전 해체 작업장 맞춤형 장비로, 방사선 분진이 많은 현장에서 정확한 공간선량률의 측정과 방사선 작업장 안전관리에 도움을 줄 수 있을 것으로 확신한다.

금융기관 전산시스템 보안 강화에 대한 연구 (For the financial institution computer system security, research)

  • 김명수;최대영;서원우;김종배
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.67-70
    • /
    • 2014
  • 최근 금융권의 주요 이슈는 보안이었고 앞으로도 보안을 더욱 강조 될 것이다. 2013년 3월20일 전산 대란, 6월 25일 사이버테러 등으로 금융 당국은 '금융전산 보안 대책' 발표와 2014년에 카드사 및 통신사 고객정보 유출 사고로 인해 '고객정보 유출방지 대책'을 공표하였고 당국은 매년 금융기관의 정보보호 실태 점검'을 실시하여 금융거래의 안정성 확보와 고객의 재산과 정보를 보호하는데 노력하고 있다. 본 연구는 IT 시스템 관리자가 보안 강화를 위한 필요 사항에 대해 본론에서 전산 시스템기기 서비스 보안, 데이터 운영서비스 보안, 보안 관제 서비스 운영, 전산 시스템 운영 관리의 보안 사항에 대해 기술하여 정보보호를 위한 업무 운영에 도움이 됐으면 한다.

  • PDF