• Title/Summary/Keyword: Square-Frame

Search Result 218, Processing Time 0.021 seconds

A Study on LMS-MPC Method Considering Low Bit Rate (Low Bit Rate을 고려한 LMS-MPC 방식에 관한 연구)

  • Lee, See-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.233-238
    • /
    • 2012
  • In a speech coding system using excitation source of voiced and unvoiced, it would be a distortion of speech waveform in case of exist a voiced and an unvoiced consonants in a frame. To solve this problem, this paper present a method of LMS-MPC uses individual pitch and LMS(Least Mean Square). I evaluate the MPC and LMS-MPC using LMS. As a result, SNRseg of LMS-MPC was improved 1.5dB for female voice and 1.3dB for male voice respectively. Compared to the MPC, SNRseg of LMS-MPC has been improved that I was able to control the distortion of the speech waveform finally. And so, I expect to be able to this method for cellular phone and smart phone using excitation source of low bit rate.

Performance Improvement of Packet Loss Concealment Algorithm in G.711 Using Adaptive Signal Scale Estimation (적응적 신호 크기 예측을 이용한 G.711 패킷 손실 은닉 알고리즘의 성능향상)

  • Kim, Tae-Ha;Lee, In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.403-409
    • /
    • 2015
  • In this paper, we propose Packet Loss Concealment (PLC) method using adaptive signal scale estimation for performance improvement of G.711 PLC. The conventional method controls a gain using 20 % attenuation factor when continuous loss occurs. However, this method lead to deterioration because that don't consider the change of signal. So, we propose gain control by adaptive signal scale estimation through before and after frame information using Least Mean Square (LMS) predictor. Performance evaluation of proposed algorithm is presented through Perceptual Evaluation of Speech Quality (PESQ) evaulation.

PIV Measurement of Airflow in a Vertical Channel With Square Heat Source (정방형 발열체를 갖는 수직채널 내부의 공기유동 관한 PIV계측)

  • Bae, S.T.;Kim, D.K.;Kim, S.P.;Cho, D.H.;Lee, Y.H.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.35-41
    • /
    • 1997
  • An experimental study was carried out in a vertical channel with square heat source by visualization equipment with laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two-frame grey-level cross correlation algorithm. Heat source was uniform heat flux(5W). The obtained results show various flow patterns such as the kinetic energy distribution and the turbulent kinetic energy distribution.

  • PDF

New Techniques for Impedance Characteristics Measurement of Islanded Microgrid based on Stability Analysis

  • Hou, Lixiang;Zhuo, Fang;Shi, Hongtao
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1163-1175
    • /
    • 2016
  • In recent years, microgrids have been the focus of considerable attention in distributed energy distribution. Microgrids contain a large number of power electronic devices that can potentially cause negative impedance instability. Harmonic impedance is an important tool to analyze stability and power quality of microgrids. Harmonic impedance can also be used in harmonic source localization. Precise measurement of microgrid impedance and analysis of system stability with impedances are essential to increase stability. In this study, we introduce a new square wave current injection method for impedance measurement and stability analysis. First, three stability criteria based on impedance parameters are presented. Then, we present a new impedance measurement method for microgrids based on square wave current injection. By injecting an unbalanced line-to-line current between two lines of the AC system, the method determines all impedance information in the traditional synchronous reference frame d-q model. Finally, the microgrid impedances of each part and the overall microgrid are calculated to verify the measurement results. In the experiments, a simulation model of a three-phase AC microgrid is developed using PSCAD, and the AC system harmonic impedance measuring device is developed.

Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm

  • Choi, Sung-Mo;Yun, Yeo-Sang;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.303-317
    • /
    • 2006
  • The connection with combined cross diaphragm is developed for the connection of square CFT column and steel beam and proposed to be used for the frame with asymmetric span length. The structural characteristics of this connection lie in the penetration of the beam flange in the direction of major axis through the column for the smooth flow of stress. The purpose of this study is to analyze the dynamic behavior and stress flow of suggested connection and to evaluate the resistance to shock of connection. Four T-type CFT column-to-beam specimens; two with combined cross diaphragm and the others with interior and through diaphragms, the existing connection types, were made for cyclic load test guided by the load program of ANSI/AISC SSPEC 2002. The results show that the proposed connection is more efficient than existing ones in terms of strength, stress flow and energy absorption and satisfies the seismic performance required in the region of weak/moderate earthquakes.

Performance Analysis of Fine Frequency Synchronization Scheme in Mobile WiMAX Systems (Mobile WiMAX 시스템에서 미세 주파수 동기화 기법의 성능 분석)

  • Yang, Hyun;Jeong, Kwang-Soo;Lee, Kyeong-Il;Yi, Jae-Hoon;You, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8A
    • /
    • pp.815-820
    • /
    • 2008
  • Carrier frequency offset (CFO) is one of the most important problems in an orthogonal frequency division multiplexing (OFDM) system, which seriously degrades the performance of the systems due to its time-variant behavior. In this paper, the performance of a pilot-assisted fine CFO estimator in OFDM-based mobile WiMAX systems is analyzed. Analytical closed-form expression of the mean square error (MSE) of the post-FFT based CFO synchronization scheme is reported for time-variant fading channels. Taking into account the frame structure of the IEEE802.16e standard, simulation results are used to verify the theoretical analysis developed in this paper.

One-touch Descending Lifeline with Sliding Linkage Structure (슬라이드 링크 구조를 이용한 원터치 완강기)

  • Kim, Wonchan;Na, Dayul;Moon, Hyein;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.9
    • /
    • pp.42-47
    • /
    • 2021
  • A one-touch descending lifeline that can easily be installed and rapidly evacuated in the event of a fire accident in high-rise buildings was proposed to overcome difficulties of conventional descending lifeline such as complex installation methods and procedures. However, this lifeline exhibits limitations such as restrictions in installation location and large apparatus size. Therefore, this paper proposes a sliding-type descending lifeline, which has a similar operation to that of current one-touch descending lifeline and solves the aforementioned limitations. A double square link mechanism including a sliding four-bar linkage is proposed and the descending lifeline support is redesigned to unfold in two different planes, allowing 3D movement. Additionally, the shape of the support frame is designed to obtain two attachment surfaces that can be attached to a wall, irrespective of the angle between the window and the inner wall. FEA analysis using ABAQUS is performed to ensure that the robustness of the presented support complies with the Fire Control Act Enforcement Decree. Finally, the feasibility of the proposed sliding one-touch descending lifeline is verified through fabrication.

A Study on the Cut Detection System of Video Data using MSE (MSE를 이용한 동영상데이터의 컷 검출시스템에 관한 연구)

  • Kim Dan-Hwan;Joung Ki-Bong;Oh Moo-Song
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.7
    • /
    • pp.1399-1404
    • /
    • 2004
  • The development of computer technology and the advancement of the technology of information and communications spread the technology of multimedia and increased the use of multimedia data with large capacity. Users can grasp the overall video data and they are able to play wanted video back. To grasp the overall video data it is necessary to offer the list of summarized video data information. In order to search video efficiently an index process of video data is essential and it is also indispensable skill. Therefore, this thesis suggested the effective method about the cut detection of frames which will become a basis of an index based on contents of video image data. This suggested method was detected as the unchanging pixel rotor intelligence value, classified into diagonal direction. Pixel value of color detected in each frame of video data is stored as A(i, i) matrix - i is the number of frames, i is an image height of frame. By using the stored pixel value as the method of UE(Mean Square Error) I calculated a specified value difference between frames and detected cut quickly and exactly in case it is bigger than threshold value set in advance. To carry out an experiment on the cut detection of lames comprehensively, 1 experimented on many kinds of video, analyzing and comparing efficiency of the cut detection system.

Strengthening of concrete structures with buckling braces and buckling restrained braces

  • Mazloom, Moosa;Pourhaji, Pardis;Farash, Abbas Moosa;Sanati, Amir Hossein
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.391-416
    • /
    • 2018
  • The purpose of this article is to strengthen concrete structures using buckling and non-buckling braces. Connection plates are modeled in three shapes including the effect of 1.5t hinge zone length, 2t one and without the zone (1.5t-CP, 2t-CP and WCP). According to the verification performed with ABAQUS software, the connection plates which are superior in ductility and strengthening are found. The results show adding steel braces in concrete moment frames increase the strength and stiffness of the structures up to about 12 and 3 times, respectively. The frame strength increased about 21 and 25 percent with considering the effect of 2t hinge length in connection plates compared to 1.5t-CPs and WCPs. Also the ductility of retrofitted frames with 2t-CP improved 2.06 times more than WCP ones. Thus, 2t-CP sample is the best choice for connecting steel braces to concrete moment frames for retrofitting them. Afterwards, optimum conditions for elemental coating in braces with no buckling are assessed. The length of concrete coatings could be reduced about 30 percent, and buckling did not occur. Therefore, the weight of restraining coating decreased, and its performance improved. It is worth noting that BRBs could be constructed with only steel materials, which have outer steel tubes too. In fact, only the square cross sections of the tube profiles are appropriate for removing the filler concrete, and the rectangular ones are prone to buckle around their weak axis.

Optimum Design of Braced Three Dimensional Square Steel Frame Structures Considering Arrangement of Major-minor axis of Column (기둥의 강·연성축을 고려한 브레이싱된 정방형 3차원 강골조 구조물의 최적설계)

  • Kim, Ki-Wook;Park, Moon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.259-267
    • /
    • 2004
  • Most steel frame structures are constructed to one side without considering the arrangement of major-minor axis of column and bracing. This research presents more safety and economic efficiency can be obtained by just rearrangement of major-minor axis. Because most of steel-frame structures are excessively designed with Allowable Stress Design, and it needs to be changed to other specifications. The arrangement of major-minor axis of column is partly referred in AISC-LRFD, but still insufficient. This study compared with the each result from rearrangement of major-minor axis of column, arrangement of bracing, the connecting method of bracing, and consequence with different specifications. Moreover it demonstrated the direction of more economically optimized design.