• Title/Summary/Keyword: Square rod

Search Result 77, Processing Time 0.02 seconds

Visual Cells of the Introduced Bluegill Lepomis macrochirus (Pisces; Centropomidae) of Korea

  • Kim, Jae Goo;Park, Jong Young
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.89-92
    • /
    • 2016
  • The bluegill Lepomis macrochirus is an invasive species, not native to Korea, introduced for aquaculture. This species is ranked as a new top predator due to its massive aquatic carnivorous and herbivorous nature by acute vision and the absence of a natural enemy. The visual cells of the retina of L. macrochirus are composed of short single cones and equal double cones and long and bulky rods by light and electron microscopes. In particular, the cones show a regular square mosaic arrangement. This pattern is widely considered as a strong predator. With regard to the visual system, this mosaic pattern may closely be related to a dynamic visual acuity to track and hunt prey.

Pass Schedule Design to Inhibit Surface Cracks Generation on Workpiece in Groove Rolling Process (공형압연 공정에서 소재 표면흠 발생억제를 위한 패스 스케줄 설계)

  • Na, Doo-Hyun;Lee, Young-Seog
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1443-1453
    • /
    • 2010
  • We simulated the roughing train of the rod mill of SEAH BESTEEL Inc. using finite element method to inhibit surface cracks initiation on workpiece. We designed 2nd pass (square roll) and applied to this roll in the roughing train of the rod mill. Also, we proposed new pass schedule, which changed roll gap of 3rd and 4th groove by using finite element method. We used shear damage model, which is dependent on shear stress ratio and compared the number of damaged elements on workpiece. A damaged element means surface crack. Consequently, after 2nd pass (square roll) is changed, the error rate decreased by 1.43% when compare to that of the old groove. And the number of damaged elements in the new pass schedule decreased by 37.6%, which is less than present pass schedule.

BEAVRS benchmark analyses by DeCART stand-alone calculations and comparison with DeCART/MATRA multi-physics coupling calculations

  • Park, Ho Jin;Kim, Seong Jin;Kwon, Hyuk;Cho, Jin Young
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1896-1906
    • /
    • 2020
  • The BEAVRS (Benchmark for Evaluation and Validation of Reactor Simulation) benchmark calculations were performed by DeCART stand-alone and DeCART/MATRA multi-physics coupled code system to verify their accuracy. The solutions of DeCART stand-alone calculations for the control rod bank worth, detector signal, isothermal temperature coefficient, and critical boron concentration agreed very well with the measurements. The root-mean-square errors of the boron letdown curves for two-cycles were less than about 20 ppm, while the individual and total control rod bank worth agreed well within 7.3% and 2.4%, respectively. For the BEAVRS benchmark calculations at the beginning of burnup, the difference between DeCART simplified thermal-hydraulic stand-alone and DeCART/MATRA coupled calculations were not significantly large. Therefore, it is concluded that both the DeCART stand-alone code and the DeCART/MATRA multi-physics coupled code system have the capabilities to generate high fidelity transport solutions at core follow calculations.

Evaluation of Standing Balance of the Elderly with Different Balance Abilities by using Kinect and Wii Balance Board

  • Yang, Seung Tae;Seo, Jung Woo;Kim, Dae Hyeok;Kang, Dong Won;Choi, Jin Seung;Tack, Gye Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.391-396
    • /
    • 2016
  • Objective: This study aimed to evaluate and identify variables for the standing balance of elderly subjects with different balancing abilities by using Kinect and Wii Balance Board. Method: The Berg Balance Scale (BBS) test was performed in 40 elderly subjects aged ${\geq}65years$ who can perform daily activities. The participants were divided into two groups, the healthy seniors (n = 20, BBS score ${\geq}52$) and the seniors with balancing problems (n = 20, BBS score < 52). Each group performed two standing tests (eyes open and eyes close) with two devices (Kinect and Wii Balance Board). The root mean square (RMS), mean distance (MDIST), range of distance (ROD), mean velocity, and 95% ellipse area were calculated from the measured data. Results: Among the calculated variables, RMS, MDIST, and ROD in the mediolateral direction showed significant differences between the two groups and a negative correlation with BBS scores. Conclusion: The results of the present study show that simple standing balance of the elderly can be measured with Kinect and Wii Balance Board, which are low-cost, easy to carry, and easy to use, by using the selected variables.

Two-way fluid-structure interaction simulation for steady-state vibration of a slender rod using URANS and LES turbulence models

  • Nazari, Tooraj;Rabiee, Ataollah;Kazeminejad, Hossein
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.573-578
    • /
    • 2019
  • Anisotropic distribution of the turbulent kinetic energy and the near-field excitations are the main causes of the steady state Flow-Induced Vibration (FIV) which could lead to fretting wear damage in vertically arranged supported slender rods. In this article, a combined Computational Fluid Dynamics (CFD) and Computational Structural Mechanic (CSM) approach named two-way Fluid-Structure Interaction (FSI) is used to investigate the modal characteristics of a typical rod's vibration. Performance of an Unsteady Reynolds-Average Navier-Stokes (URANS) and Large Eddy Simulation (LES) turbulence models on asymmetric fluctuations of the flow field are investigated. Using the LES turbulence model, any large deformation damps into a weak oscillation which remains in the system. However, it is challenging to use LES in two-way FSI problems from fluid domain discretization point of view which is investigated in this article as the innovation. It is concluded that the near-wall meshes whiten the viscous sub-layer is of great importance to estimate the Root Mean Square (RMS) of FIV amplitude correctly as a significant fretting wear parameter otherwise it merely computes the frequency of FIV.

A validation study of the SLTHEN code for hexagonal assemblies of wire-wrapped pins using liquid metal heating experiments

  • Sun Rock Choi;Junkyu Han;Huee-Youl Ye;Jonggan Hong;Won Sik Yang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1125-1134
    • /
    • 2024
  • This paper presents a validation study of the subchannel analysis code SLTHEN used for the core thermal-hydraulic design of the Prototype Gen-IV sodium-cooled fast reactor (PGSFR). To assess the performance of the ENERGY model of SLTHEN, four liquid metal heating experiments conducted by ORNL, WARD, and KIT with hexagonal assemblies of wire-wrapped rod bundles were analyzed. These experiments were performed with 19-and 61-pin bundles and varying power distributions of axial and radial peaking factors up to 1.4 and 3.0, respectively. The coolant subchannel temperatures measured at different axial locations were compared with the SLTHEN predictions with the Novendstern, Chiu-Rohsenow-Todreas (CRT), and Cheng-Todreas (CT) correlations for flow split and mixing in wire-wrapped pin bundles. The results showed that the SLTHEN predicts the measured subchannel temperatures reasonably well with root-mean-square errors of ~10 % and maximum errors of ~20 %. It was also observed that the CRT and CT correlations consistently outperform the Novendstern correlation.

Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly (이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토)

  • Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2017
  • The forced convection heat transfer performance of a twist-vane spacer grid for a dual-cooled annular fuel assembly was examined experimentally. The twist-vane spacer grid was uniquely designed to enhance mixing inside subchannels and mixing between adjacent subchannels. For testing, a $4{\times}4$ square-arrayed rod bundle with narrow gaps between rods was prepared as the dual-cooled annular fuel assembly to be simulated. The pitch-to-rod diameter ratio of simulated dual-cooled annular fuel assembly was 1.08. The experiments were performed under the following conditions: axial bulk velocity, 1.5 m/s and heat flux, $26kW/m^2$. With regard to the circumferential temperature distribution, the lowest rod-wall temperatures upstream and downstream were measured at the subchannel center and the position toward the tip of twist-vane, respectively. With regard to the axial temperature distribution, behind the twist-vane spacer grid, the rod-wall temperature decreased drastically, and the Nusselt number was enhanced by up to 56 %. The present measured data indicate that the twist-vane spacer grid can effectively improve the forced convection heat transfer in the dual-cooled annular fuel assembly with narrow gaps.

Pin Power Distribution Determined by Analyzing the Rotational Gamma Scanning Data of HANARO Fuel Bundle

  • Lee, Jae-Yun;Park, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.452-461
    • /
    • 1998
  • The pin power distribution is determined by analyzing the rotational gamma scanning data for 36 element fuel bundle of HANARO. A fission monitor of Nb$^{95}$ is chosen by considering the criteria of the half-life, fission yield, emitting ${\gamma}$-ray energy and probability. The ${\gamma}$-ray spectra were measured in Korea Atomic Energy Research Institute(KAERI) by using a HPGe detector and by rotating the fuel bundle at steps of 10$^{\circ}$. The counting rates of Nb$^{95}$ 766 keV ${\gamma}$-rays are determined by analyzing the full absorption peak in the spectra. A 36$\times$36 response matrix is obtained from calculating the contribution of each rod at every scanning angle by assuming 2-dimensional and parallel beam approximations for the measuring geometry. In terms of the measured counting rates and the calculated response matrix, an inverse problem is set up for the unknown distribution of activity concentrations of pins. To select a suitable solving method, the performances of three direct methods and the iterative least-square method are tested by solving simulation examples. The final solution is obtained by using the iterative least-square method that shows a good stability. The influences of detection error, step size of rotation and the collimator width are discussed on the accuracy of the numerical solution. Hence an improvement in the accuracy of the solution is proposed by reducing the collimator width of the scanning arrangement.

  • PDF

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF

Finite Element Analysis to Reduce the Wrinkle Initiation of Workpiece in Groove Rolling (공형압연에서 소재 주름흠 발생 감소를 위한 유한요소해석)

  • Na, D.H.;Cho, O.Y.;Lee, J.H.;Lee, Y.H.;Lee, Y.
    • Transactions of Materials Processing
    • /
    • v.17 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • A criterion which predicts wrinkle initiation on workpiece in groove rolling process based on finite element analysis is proposed. Fundamental idea considered in the criterion is using the difference between flat rolling which don't cause wrinkling at all and groove rolling which usually accompanies it. The proposed criterion assumes that irregular distribution of shear strain on workpiece during groove rolling is attributable to the initiation of wrinkling. The proposed criterion has been applied to roughing train in the rod mill of SEAH BESTEEL Inc. A new design of 2nd pass (square roll groove) was suggested, machined and applied. Results reveal that the proposed criterion could point out the location of wrinkle initiation and could reduce onset of wrinkle.