• 제목/요약/키워드: Square pulse

검색결과 259건 처리시간 0.026초

Tearing of metallic sandwich panels subjected to air shock loading

  • Zhu, Feng;Lu, Guoxing;Ruan, Dong;Shu, Dong-Wei
    • Structural Engineering and Mechanics
    • /
    • 제32권2호
    • /
    • pp.351-370
    • /
    • 2009
  • This paper presents a computational study for the structural response of blast loaded metallic sandwich panels, with the emphasis placed on their failure behaviours. The fully-clamped panels are square, and the honeycomb core and skins are made of the same aluminium alloy. A material model considering strain and strain rate hardening effects is used and the blast load is idealised as either a uniform or localised pressure over a short duration. The deformation/failure procedure and modes of the sandwich panels are identified and analysed. In the uniform loading condition, the effect of core density and face-sheets thicknesses is analysed. Likewise, the influence of pulse shape on the failure modes is investigated by deriving a pressure-impulse (P-I) diagram. For localised loading, a comparative study is carried out to assess the blast resistant behaviours of three types of structures: sandwich panel with honeycomb core, two face-sheets with air core and monolithic plate, in terms of their permanent deflections and damage degrees. The finding of this research provides a valuable insight into the engineering design of sandwich constructions against air blast loads.

Study of Metabolic Profiling Changes in Colorectal Cancer Tissues Using 1D 1H HR-MAS NMR Spectroscopy

  • Kim, Siwon;Lee, Sangmi;Maeng, Young Hee;Chang, Weon Young;Hyun, Jin Won;Kim, Suhkmann
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권5호
    • /
    • pp.1467-1472
    • /
    • 2013
  • Metabolomics is a field that studies systematic dynamics and secretion of metabolites from cells to understand biological pathways based on metabolite changes. The metabolic profiling of intact human colorectal tissues was performed using high-resolution magic angle spinning (HR-MAS) NMR spectroscopy, which was unnecessary to extract metabolites from tissues. We used two different groups of samples, which were defined as normal and cancer, from 9 patients with colorectal cancer and investigated the samples in NMR experiments with a water suppression pulse sequence. We applied target profiling and multivariative statistical analysis to the analyzed 1D NMR spectra to identify the metabolites and discriminate between normal and cancer tissues. Cancer tissue showed higher levels of arginine, betaine, glutamate, lysine, taurine and lower levels of glutamine, hypoxanthine, isoleucine, lactate, methionine, pyruvate, tyrosine relative to normal tissue. In the OPLS-DA (orthogonal partial least square discriminant analysis), the score plot showed good separation between the normal and cancer groups. These results suggest that metabolic profiling of colorectal cancer could provide new biomarkers.

위상시간법에 의한 초음파전파시간의 결정에 관한 연구 (A study on the determination of Ultrasonic Travel Time by Norm Phase-Time Method)

  • 이은방
    • 한국항해학회지
    • /
    • 제18권4호
    • /
    • pp.137-146
    • /
    • 1994
  • In this paper, a new algorithm to measure the ultrasonic travel time is proposed, which is fundamental to estimate distance depth and volume in several media. Pulse wave has been used to measure travel time of transmitted signal. However, due to the characteristic of transducer and propagation, the received signal is so distorted that it is difficult to measure travel time, which is propagation, the received signal is so distorted that it is difficult to measure travel time, which is to be time difference between transmitted and received signals. In this proposed method, transmitted and received signal are transformed respectively into norm phase newly designed by this paper and displayed on phase-time curve. And travel time is simply determined by the arithmetic numerical mean of time difference at the identical norm phase on the phase-time curves of transmitted and received signals. This method has several features; firstly, travel time is calculated analytically with high accuracy by least square error method, secondly, it is useful to compare the difference of signal magnitude for time information, thirdly, noise and discrete errors are relatively small, finally, the measurement accuracy is not influenced by D.C. bias. In particular, this method is useful and applicable to measuring very short distance and sound speed with high accuracy.

  • PDF

Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법 (A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter)

  • 이준영;최현준;김주용;정지훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

협대역 고출력 전자기파에 의한 포토커플러 영향 분석 (The Analysis of Effect for Photocoupler by Narrow-Band High-Power Electromagnetic Wave)

  • 이성우;허창수;서창수;진인영
    • 한국전기전자재료학회논문지
    • /
    • 제31권1호
    • /
    • pp.1-5
    • /
    • 2018
  • This study analyzed the change of electrical characteristics of a photocoupler when a narrow-band electromagnetic wave was combined with the photocoupler. A magnetron (3 kW, 2.45 GHz) was used as the narrow-band electromagnetic source. The EUT was Photocoupler (6N139) and the input signal was divided into two types: a square pulse and the second signal is 0 V. The malfunction of the photocoupler was confirmed by monitoring the variation in the output voltage of the photocoupler. As a result of the experiment, changes in the malfunctioning was observed as the electric field was increased. There are three types of malfunction modes: delay, output voltage off, and fluctuation. Bit errors were analyzed to verify the electrical characteristics of the photocoupler by narrow-band electromagnetic waves. The result of this study can be used as basic data for the effect analysis of photocoupler protection and impact analysis of high-power electromagnetic waves.

저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석 (Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN)

  • 기명오;최성수;오휘명;김관호
    • 한국통신학회논문지
    • /
    • 제30권11A호
    • /
    • pp.1027-1034
    • /
    • 2005
  • 수십 센터미터 이내의 오차를 만족시키는 거리/위치인식 기능 및 저속 데이터 송수신 기능 구현을 주목적으로 발족된 저속 WPAN(LR-WPAN: Low Rate Wireless Personal Area Network)의 표준화 그룹인 IEEE802.15.4a에서는 간단하고 경제적이며 전력 소모가 적은 송수신기 구조를 요구한다. 이에 본 논문에서는 PEWB(Parallel Energy Window Banks)를 이용한 독창적인 비동기 OOK(On-Off Keying) 방식 UWB(Ultra-Wide Band) 송수신기 구조를 제안한다. 또한 무선 다중경로 페이딩 채널 상황을 다소 극복할 수 있게 유연성 있는 운영이 가능한 송수신기 구조를 위해 펄스 및 비트 반복 기법을 사용한다. 제안된 송수신기 구조의 잡음 특성 분석을 위해 chi-square 분포가 적용되며, 반복적 계산을 통해 얻어진 최적임계값을 적용하며 비트오율 성능을 분석한다. 모의실험 결과, 10-5의 비트오율을 얻기 위한 신호대잡음비 및 수신에너지 적분시간은, LOS(Line-Of-Sight) 주거 환경의 경우 15.3dB, 32ns이고, NLOS(Non-Line-Of-Sight) 실외 환경의 경우 16.2dB, 72ns이다. 최소의 비트오율을 얻기 위한 적분에너지 대 전체 수신에너지 비는 약 $86\%$이다.

광조사 방식이 복합레진의 중합과 누출에 미치는 영향 (THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 박종진;박정원;박성호;박주명;권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.158-174
    • /
    • 2002
  • Filtek$^{TM}$ Z-250(3M Dental Products, St. Paul., MN. USA) 광중합형 복합레진을 대상으로 다양한 광조사 방식이 중합수축, 중합도 및 미세누출에 미치는 영향을 알아보고자 하였다. VIP$^{TM}$(Bisco Dental Products, Schaumburg, IL, USA)를 이용하여 200, 400 및 600mW/$\textrm{cm}^2$의 일정한 광도로 중합시킨 세 군(V2, V4 및 V6군)과 200mW/$\textrm{cm}^2$의 광도로 3초간 중합시키고 5분간 방치 한 후 다시 600mW/$\textrm{cm}^2$의 광도로 중합시키는 pulse-delay 방식을 이용한 군(VPD군) 그리고 Optilux 501$^{TM}$(Demetron/Kerr, Danbury, CT, USA)을 이용하여 C-mode와 R-mode로 중합시킨 두 군(OC군, OR군) 등 모두 6개의 군으로 나누어 실험하였으며, 복합레진의 중합과 누출을 다음의 네 가지 방법으로 측정하였다. 첫째, V2, V4, V6, OC군은 60초간, OR군은 20초간 그리고 VPD군은 두번째 광조사를 60초간 시행하면서 시간에 따른 선형 중합수축을 Linometer(R&B, Daejeon, Korea)로 측정하였다. 둘째, V2, V4, V6, OC군은 각각 5, 10, 20, 40, 60초간 그리고 OR군과 VPD군은 정해진 조건에 따라 중합시킨 2mm 두께 시편의 바닥면에서 시료를 채취한 후 KBr method로 시편을 제작하고, FTIR spectrometer(IFS 120 HR, Broker, Karlsruhe, Germany)로 미반응 잔류단량체의 양을 계측하여 중합도를 측정하였다. 셋째, 두번째 실험과 같은 조건으로 중합시킨 2mm 두께 시편의 광조사면과 바닥면에서 중합 10분 후 미세경도 측정기(FM7, Future-Tech Co., Tokyo, Japan)로 500g의 하중을 10초간 가하여 Knoop Hardness Number(KHN) 값을 측정하였다. 끝으로, 90개의 발거치 치경부에 제5급 와동을 형성하고 V2군은 60초간, V4군은 40초간, V6군은 30초간 그리고 OC, OR, VPD군은 정해진 조건에 따라 중합시킨 후, methylene blue 용액에 침적시키고 종절단하여 법랑질과 상아질 변연의 미세누출 정도를 측정하였다. 중합수축. 중합도 및 미세경도 측정치는 one-way ANO-VA와 Duncan's multiple range test를, 변연누출 정도는 chi-square test를 이용, 통계처리하여 다음의 결과를 얻었다. . 중합수축의 정도는 VIP$^{TM}$(Bisco) 사용군에서 전체 조사광도가 높을수록 큰 경향을 보여 600mW/$\textrm{cm}^2$군에서 가장 크게 나타났고, 그 다음으로 Pulse-delay군, 400mW/$\textrm{cm}^2$군, 200 mW/$\textrm{cm}^2$군 순이었고, Optilux 501$^{TM}$(Demetron/Kerr) 사용군에서는 Continuous 방식이 Ramp 방식 보다 크게 나타났다. . 중합도와 미세경도 값은 공히, 전체 조사광도가 높을수록 높게 나타났으며 , 최종 중합도는 44.77~54.98%의 범위를, 미세경도 값은 34.10~56.30의 범위를 보였다. . 미세누출은 전반적으로 상아질 변연이 법랑질 변연에 비해 많았고, VIP$^{TM}$(Bisco) 사용 군에서는 광도가 높을수록 상아질 변연에서 미세누출이 증가하는 양상을 보였으며, 법랑질 변연에서는 Optilux 501$^{TM}$(Demetron/Kerr)의 Continuous 방식이, 상아질 변연에서는 Ramp 방식이 가장 적은 미세누출을 보였다.

사질토양에서의 Benzene의 이동성에 관한 연구 (Transport and Fate of Benzene in a Sandy Soil)

  • 백두성;김동주
    • 대한지하수환경학회지
    • /
    • 제6권2호
    • /
    • pp.95-100
    • /
    • 1999
  • 토립자 표면에서의 흡착에 의한 토양에서의 탄화수소계 화합물의 지연효과는 잘 알려진 현상이다. 본 연구에서는 배치시험과 주상시험을 수행함으로써 사질토양에서 Benzene의 이동성에 대한 지연효과를 조사하였다. 배치시험을 위하여 토양시료와 다양한 초기농도의 Benzene 용액을 48시간 반응시켰고. 초기용액과 평행상태의 Benzene 용액의 농도를 HPLC를 이용하여 분석하였다. 주상시험은 파괴곡선으로 알려진 시간에 따른 용액의 농도를 측정함으로써 수행되었다. 추적자로는 10 g/L 농도의 KCI과 0.88 g/L의 Benzene 용액을 사용하였고 .각각의 용액을 토양시료의 상부경계면에 순간주입한 후 정상류 상태에서 배출구로 빠져나온 용탈수의 농도를 EC-meter와 HPLC를 이용하여 측정하였다. 배치시험의 결과로부터 linear adsorption isotherm에 의한 분배계수가 측정되었고 주상시험 조건의 용적밀도 및 함수율을 고려한 지연계수가 산정되었다. 주상시험의 결과 i) Benzene의 첨두농도는 KCl 첨두농도보다 상당히 낮았으나. ⅱ) 첨도농도의 도달시간은 거의 일치하였다. 첨두농도의 도달시간이 일치한다는 결과는 지연효과가 일어나지 않았다는 것을 지시하며, 배치시험의 결과로부터 산정된 지연계수를 고려하여 예측된 파과곡선은 Benzene의 주상시험 결과와 일치하지 않았다. Benzene 농도의 뚜렷한 감소를 설명할 수 있는 유일한 방법은 convection-dispersion equation(CDE) 모델에서 비가역 흡착에 의한 농도의 절대적 감소를 고려하는 감쇄계수(decay or sink coefficient)를 적용해야 하는 것으로 판단된다.

  • PDF

생체모방형 비대칭 나노채널을 갖는 산화알루미늄 분리막 제조 및 이온 정류 특성 (Fabrication and Ionic Current Rectification Characteristics of Biomimetic Aluminum Oxide Membrane)

  • 정재훈;김종영;최기운;이준호;강일석;안치원;조철희
    • 멤브레인
    • /
    • 제30권3호
    • /
    • pp.181-189
    • /
    • 2020
  • 본 연구에서는 생체모방형 비대칭 분리막 제조방법인 사각펄스양극산화법의 비대칭성 한계를 극복하기 위해 최근 보고된 셀렌산 전해액을 이용하고 표면개질에 따른 정류특성을 평가하였다. 분리막의 비대칭 원뿔형 채널은 최소직경이 10 nm이고 최대직경이 50 nm이며 길이가 5 ㎛이었다. 분리막의 정류특성은 기존 황산 전해액에서 제작된 것보다 높았으며 +1V에서의 전류가 -1 V일 때보다 최대 2.9배를 나타내었다. 또한, 실란화 반응을 이용한 표면개질을 통해 술폰산기를 도입한 분리막은 반대로 -1 V에서의 전류가 +1 V일 때보다 전류의 최대 4.2배인 정류특성을 나타냈다. 실험에 대한 이론적 증명은 2D 모델에 수치해석 결과를 제시함으로써 뒷받침되었다. 본 연구의 결과는 서로 다른 정류방향을 갖는 두 종류의 이온 정류 분리막을 손쉽게 제작할 수 있는 방법을 제시하며 이온의 이동을 제어하기 위한 다양한 연구 분야에 활용될 수 있을 것으로 기대된다.

시간영역 광전자파 분석기(Automatic TDR System)를 이용한 오염물질의 거동에 관한 연구: 실험방법 및 검정 (Application of an Automated Time Domain Reflectometry to Solute Transport Study at Field Scale: Experimental Methodology and Calibration of TDR)

  • 김동주
    • 자원환경지질
    • /
    • 제29권6호
    • /
    • pp.699-712
    • /
    • 1996
  • 자동 TDR 시스템을 이용하여 약 0.54 헥타 크기의 2개 현장에서 오염물질의 거동을 모니터링하였다. 오염물질의 수직적 플륨을 관측하기 위하여 추적자로서 $CaCl_2$를 순간주입(Pulse)방식으로 투입하였으며 오염물질 이동시간의 공간적 이질성과 현장규모의 운송모델 개념을 파악하기 위하여 횡방향으로 24개 지점과 5개의 다른 깊이, 즉 120개 지점에 50 cm 길이의 TDR 탐사침을 설치하여 잔존수 농도를 측정하였다. TDR에 의해 관측된 전기전도도를 검정하기 위하여 3가지의 다른 방법을 사용하였다. 깊이별 24개 지점에서 얻어진 평균 BTC 자료를 이용하여 CDE 모델과 CLT 모델의 파라미터를 추정한 결과 TDR 방법은 실내실험 뿐만아니라 현장에서의 오염물질 거동 분석에 유용하다는 결론을 얻었다. 또한 3가지 검정방법은 BTC 모양과 특히 오염물질의 첨두운송시간과 관련된 파라미터에 큰 영향을 미치지 않으며 사용된 검정방법 중 SLM 방법이 수평적으로 설치된 TDR 탐사침에 대해서 가장 적합한 것으로 나타났다.

  • PDF