• Title/Summary/Keyword: Square array

Search Result 262, Processing Time 0.027 seconds

Infrared and Radio observations of a small group of protostellar objects in the molecular core, L1251-C

  • Kim, Jungha;Lee, Jeong-Eun;Choi, Minho;Bourke, Tyler L.;Evans II, Neal J.;Di Francesco, James;Cieza, Lucas A.;Dunham, Michael M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.67.4-68
    • /
    • 2015
  • We present a multi-wavelength observational study of a low-mass star-forming region, L1251-C, with observational results at wavelengths from the near-infrared to the millimeter. Spitzer Space Telescope observations confirmed that IRAS 22343+7501 is a small group of protostellar objects. The extended emission to east-west direction with its intensity peak at the center of L1251A has been detected at 350 and 850 mm with the CSO and JCMT telescopes, tracing dense envelope materials around L1251A. The single-dish data from the KVN and TRAO telescopes show inconsistencies between the intensity peaks of several molecular line emission and that of the continuum emission, suggesting complex distributions of molecular abundances around L1251A. The SMA interferometer data, however, show intensity peaks of CO 2-1 and $^{13}CO$ 2-1 located at the position of IRS 1, which is both the brightest source in IRAC image and the weakest source in the 1.3 mm dust continuum map. IRS 1 is the strongest candidate for being the driving source of a newly detected the compact CO 2-1 outflow. Over the whole region ($14^{\prime}{\times}14^{\prime}$) of L125l-C, 3 Class I and 16 Class II sources have been detected, including three YSOs in L1251A. A comparison with the average projected distance among 19 YSOs in L1251-C and that among 3 YSOs in L1251A suggests L1251-C is an example of low-mass cluster formation, where protostellar objects are forming in a small group.

  • PDF

Modal Characteristics of Control Element Assembly Shroud for Korean Standard Nuclear Power Plant(II : Test and Post-Test Analysis) (한국표준형 원자력발전소 제어봉집합체 보호구조물의 모우드 특성 II)

  • Jhung, Myung-Jo;Park, Keun-Bae;Song, Heuy-Gap;Choi, Suhn
    • Computational Structural Engineering
    • /
    • v.5 no.4
    • /
    • pp.93-102
    • /
    • 1992
  • The design of reactor internals requires the accurate vibration characteristics of each component for subsequent dynamic structural response analyses. For Korean standard nuclear power plant some modifications on the Control Element Assembly shroud from the reference design have been made, Since the shroud is complex in geometry having an array of vertical round tubes and webs in a square grid pattern, and being tied down by preloaded tie rods into position, it is planned to perform a vibration measurement program consisting of both experimental and analytical modal studies upon that component. The shroud modal testing was performed on the low frequency global survey to measure the first several modes. The analysis using the finite element model was also performed for the as-tested conditions. The natural frequencies and mode shapes from both test and analysis have been acquired and compared to be in good agreement. It is concluded that finite element model generated is good enough to be used in the design for the dynamic response analysis under various loading conditions.

  • PDF

Gain Enhancement of a Horn Antenna with Latticed Aperture (격자로 분할된 개구면을 갖는 혼 안테나의 이득 개선)

  • Hur, Moon-Man;Lee, In-Jae;Lim, Gye-Jae;Yoon, Hyun-Bo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.1000-1006
    • /
    • 2006
  • In this paper, the gain of the square hem antenna is enhanced with $3{\times}3$ latticed aperture. In order to get the uniform field distribution on the aperture, the different thicknesses of dielectric plates for the phase compensation are inserted into the center and the edge of the aperture respectively. The proposed horn antenna is designed at 12.5 GHz band, and then the analysis of the field distribution on the aperture is performed by using FDTD method. The radiation pattern is also calculated from the analysis. Based on the measured data, it is verified that the gain of a horn antenna with latticed aperture is 18 dBi and this is 2 dB gain enhancement compare with a normal horn antenna without latticed aperture.

Design of Dual-Polarized Monopulse Cassegrain Antenna for W-Band Millimeter-Wave Seeker (W-대역 탐색기용 이중편파 모노펄스 카세그레인 안테나 설계)

  • Lee, Kook Joo;Jung, Chae-Hyun;Baek, Jong-Gyun;Park, Chang-Hyun;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.261-268
    • /
    • 2016
  • In this paper, dual-polarized monopulse cassegrain antenna for W-band millimeter-wave seeker was proposed and the performances were verified by the measured results of the fabricated antenna. Dual-polarized monopulse Cassegrain antenna consists of main/subreflector, dual-polarized feed horn and monopulse comparator. The proposed feed horn has $2{\times}2$ array square waveguide feeding structure to make monopulse signals and it was designed using 90 degree rotational symmetric structure to receive dual-polarized signals. At the sum and difference channel, the measured vertical and horizontal polarization radiation pattern were similar. Measurement gains are 35.1 dBi for v-pol. and 35.6 dBi for h-pol. at the center frequency with 0.5dBi difference between each polarization and the side lobe level is below -21.6 dB.

Experimental Study about Two-phase Damping Ratio on a Tube Bundle Subjected to Homogeneous Two-phase Flow (균질 2상 유동에 놓인 관군에 작용하는 감쇠비에 대한 실험적 연구)

  • Sim, Woo Gun;Dagdan, Banzragch
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.171-181
    • /
    • 2017
  • Two-phase cross flow exists in many shell-and-tube heat exchangers such as condensers, evaporators, and nuclear steam generators. The drag force acting on a tube bundle subjected to air/water flow is evaluated experimentally. The cylinders subjected to two-phase flow are arranged in a normal square array. The ratio of pitch to diameter is 1.35, and the diameter of the cylinder is 18 mm. The drag force along the flow direction on the tube bundles is measured to calculate the drag coefficient and the two-phase damping ratio. The two-phase damping ratios, given by the analytical model for a homogeneous two-phase flow, are compared with experimental results. The correlation factor between the frictional pressure drop and the hydraulic drag coefficient is determined from the experimental results. The factor is used to calculate the drag force analytically. It is found that with an increase in the mass flux, the drag force, and the drag coefficients are close to the results given by the homogeneous model. The result shows that the damping ratio can be calculated using the homogeneous model for bubbly flow of sufficiently large mass flux.

Delineation of water seepage in earth-fill embankments by electrical resistivity method (전기비저항탐사에 의한 제당의 누수구간 탐지)

  • 정승환;김정호;양재만;한규언;김영웅
    • The Journal of Engineering Geology
    • /
    • v.2 no.1
    • /
    • pp.47-57
    • /
    • 1992
  • Geophysical methods applied to water seepage problem in earth-fill embankment attempt to detect and map the estimate of size and depth of the seepage path. Seepage zones generally produce lOW resistivity anomalies due to high saturation of water. Dipole-dipole resistivity surveying technique, which is actually a combined sounding-profiling procedure, was used to delineate the seepage path through this study. In this study, the finite difference methods to solve the electric potential distribution in 2 112 dimension, was adopted as the numerical scheme for the forward problem. Second order Marquart's method, one the iterative damped least square methods, was selected for the automatic inversion. The computer program was implemented in FORTRAN 77 for 1 6-bit personal computer. In this paper, we present a case history which illustrates the application of dipole-dipole resistivity method to the delineation of water flow in earth-fill structures. Also the automatic two-dimensional resistivity inversion was applied to a field data where the interpretive advantages of the program become evident.

  • PDF

Soil Profile Measurement of Carbon Contents using a Probe-type VIS-NIR Spectrophotometer (프로브형 가시광-근적외선 센서를 이용한 토양의 탄소량 측정)

  • Kweon, Gi-Young;Lund, Eric;Maxton, Chase;Drummond, Paul;Jensen, Kyle
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.382-389
    • /
    • 2009
  • An in-situ probe-based spectrophotometer has been developed. This system used two spectrometers to measure soil reflectance spectra from 450 nm to 2200 nm. It collects soil electrical conductivity (EC) and insertion force measurements in addition to the optical data. Six fields in Kansas were mapped with the VIS-NIR (visible-near infrared) probe module and sampled for calibration and validation. Results showed that VIS-NIR correlated well with carbon in all six fields, with RPD (the ratio of standard deviation to root mean square error of prediction) of 1.8 or better, RMSE of 0.14 to 0.22%, and $R^2$ of 0.69 to 0.89. From the investigation of carbon variability within the soil profile and by tillage practice, the 0-5 cm depth in a no-till field contained significantly higher levels of carbon than any other locations. Using the selected calibration model with the soil NIR probe data, a soil profile map of estimated carbon was produced, and it was found that estimated carbon values are highly correlated to the lab values. The array of sensors (VIS-NIR, electrical conductivity, insertion force) used in the probe allowed estimating bulk density, and three of the six fields were satisfactory. The VIS-NIR probe also showed the obtained spectra data were well correlated with nitrogen for all fields with RPD scores of 1.84 or better and coefficient of determination ($R^2$) of 0.7 or higher.

Modal Characteristics of Control Element Assembly Shroud for Korean Standard Nuclear Power Plant(I) : Pre-Test Analysis (한국표준형 원자력발전소 제어봉집합체 보호구조물의 모우드 특성)

  • Jhung, Myung-Jo;Choi, Suhn;Song, Heuy-Gap;Park, Keun-Bae
    • Computational Structural Engineering
    • /
    • v.5 no.3
    • /
    • pp.105-112
    • /
    • 1992
  • The design of reactor internals requires the accurate vibration characteristics of each component for subsequent dynamic structural response analysis. For Korean standard nuclear power plant some modifications on the Control Element Assembly shroud from the reference design have been made. Since the shroud is complex in geometry having an array of vertical round tubes and webs in a square grid pattern, and being tied down by preloaded tie rods into position, it is planned to perform a vibration measurement program consisting of both experimental and analytical modal studies upon that component. To determine the proper test conditions, the pre-test analysis has been performed using the general purpose structural analysis program ANSYS. Also the effects of the number of master degrees of freedom, holes in the web and tie-rod preload on the natural frequencies are examined prior to the pre-test analysis. After decision of appropriate finite element model, frequency analysis and harmonic analysis are performed and ideas for the test conditions such as the number of measurement points, their locations, measurement frequency range and the excitation force level are determined.

  • PDF

A Study on Digital RF System with Interference Cancellation System (간섭제거기를 적용한 디지털 RF 시스템에 관한 연구)

  • Joo, Ji-Han;Lee, Sang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1252-1263
    • /
    • 2009
  • In this paper, in order to improve a service quality and to broaden the service coverage in the mobile communication system a study on a digital RF repeater employed with an Interference Cancellation System(ICS) is performed. The digital RF repeater employed with an ICS is implemented to remove interference and feedback signals which are disadvantages of a conventional(or general) RF repeater. This thesis presents the design and experiments of the new wireless repeater. The proposed wireless repeater consists of a RF repeater mounted with digital engine. The digital ICS engine consists of a DSP and FPGA. The digital engine and RF circuit are designed into a one-piece. After developing hardware through the digital platform they are also designed and fabricated into a one-piece in order to apply a best performance repeater system. The method of removing interference and feedback signals is an adaptive IF technique employed with a LMS algorithm. The powerful performance and fast convergence speed is obtained by using this method.

Implementation of a Coded Aperture Imaging System for Gamma Measurement and Experimental Feasibility Tests

  • Kim, Kwangdon;Lee, Hakjae;Jang, Jinwook;Chung, Yonghyun;Lee, Donghoon;Park, Chanwoo;Joung, Jinhun;Kim, Yongkwon;Lee, Kisung
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • Radioactive materials are used in medicine, non-destructive testing, and nuclear plants. Source localization is especially important during nuclear decommissioning and decontamination because the actual location of the radioactive source within nuclear waste is often unknown. The coded-aperture imaging technique started with space exploration and moved into X-ray and gamma ray imaging, which have imaging process characteristics similar to each other. In this study, we simulated $21{\times}21$ and $37{\times}37$ coded aperture collimators based on a modified uniformly redundant array (MURA) pattern to make a gamma imaging system that can localize a gamma-ray source. We designed a $21{\times}21$ coded aperture collimator that matches our gamma imaging detector and did feasibility experiments with the coded aperture imaging system. We evaluated the performance of each collimator, from 2 mm to 10 mm thicknesses (at 2 mm intervals) using root mean square error (RMSE) and sensitivity in a simulation. In experimental results, the full width half maximum (FWHM) of the point source was $5.09^{\circ}$ at the center and $4.82^{\circ}$ at the location of the source was $9^{\circ}$. We will continue to improve the decoding algorithm and optimize the collimator for high-energy gamma rays emitted from a nuclear power plant.