• Title/Summary/Keyword: Square Design

Search Result 2,563, Processing Time 0.03 seconds

A Study on Scarf Design Development with a Combination of Traditional Korean Rice Cake Pattern and Jogakbo Patchwork (전통 떡살문양과 조각보를 조합한 스카프디자인 개발)

  • Kim, Sun-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.50 no.1
    • /
    • pp.29-39
    • /
    • 2012
  • The purpose of this research is to suggest a scarf design which reflects the traditional culture native to Korea by making use of the combined pattern of jokgakbo patchwork and ddeoksal(rice cake). For research methodology, the computer design programs of Adobe Illustrator CS3 and Adobe Photoshop CS3 were used along with the related literature. For the combined sets of motif pattern, the following were consider: first, a combination of jogakbo in square shape and chrysanthemum in a rice cake mold; second, a combination of radius jogakbo and geometrical pattern; third, a combination of vertical and horizontal forms of jogakbo and rice cake pattern; fourth, a combination of yeouijumunbo and butterfly pattern in rice cake mold. For the scarf design with these applications, technical skills such as repeat, rotation, symmetry, free setup, and distortion were used for the combination motif. In terms of the shape of the design, there are two, square and lengthwise tetragons.

A Study on Design Area of Fire Sprinkler System (스프링클러설비의 설계면적에 대한 연구)

  • Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.93-98
    • /
    • 2010
  • Even though the sprinkler system is a essential fire suppression system, the design engineers do not fully understand the concept of design area which sprinklers operate. They frequently made a mistake to form design area and calculate it. The shape of design area is a square or a rectangle which branch side line is a little longer than the cross main side. NFPA demands to lengthen the branch side to 1.2 times than the cross main side and FM demands 1.4 times. The longer the branch side at the same design area is, the bigger the water quantity and pressure is. At the results of hydraulic calculation of design areas, when the branch side is longer 1.2 times, the water quantity became 4.6% bigger than exact square and the pressure came to 4.67% bigger. When it is longer 1.4 times, the water quantity and the pressure are bigger 7.52%, 14.51%. Therefore, the sprinkler design engineers should follow the general rule of design area, exact square or rectangle which length along the branch line is a little longer than length along the cross main, to design more stable system.

Circularly Polarized Square Ring Slot Antenna with Arrow-Shaped Structure

  • Sung, Young-Je
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.506-509
    • /
    • 2009
  • A novel design of a compact square-ring slot microstrip antenna for achieving circular polarization (CP) operation is proposed and experimentally studied. By using an arrow-shaped slot structure as a radiating element, the resonant frequency of the proposed antenna is significantly lowered, which can lead to a large size reduction for fixed frequency operation. The CP radiation characteristics are achieved by loading with proper asymmetry, which can be placed diagonally. A prototype of the proposed design is implemented and its performance is measured. Measured results show that radiation patterns with good CP characteristics are obtained at the resonant frequency.

Design of Broadband Electromagnetic Wave Absorber with Square Ferrite Cylinders in the Second Layer (초광대역특성을 갖는 정방형 페라이트 기둥구조의 전파흡수체 설계법)

  • 김동일;전상엽;이창우;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 1995
  • A wide band design method of an electromagnetic wave absorber with square ferrite cylinders in the second layer, which has very wide band frequency characteristics, is proposed and discussed. A theoretical model using the equivalent material constants method is also evaluated and proposed for its accuracy by comparison with Hashin-Shtrikman formulas. Based on the developed model, wide band electromagnetic wave absorbers with excellent reflective frequency characteristics in the frequency range of 30MHz to 3, 690MHz were designed.

  • PDF

A Study on the Design of Two-Dimensional FIR Digital Filters using Least-Square Error Algorithm (최소자승오차 알고리즘을 이용한 2차원 FIR 디지털필터설계)

  • Ku, Ki-Jun;Cho, Byung-Ha;Lee, Doo-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.285-289
    • /
    • 1988
  • This paper suggests the way to improve the impulse response characteristics in 1-D and 2-D FIR digital filters design. The proposed a Least Square($L_2$) error algorithm of kaiser window is the better than $L_2$ error of the Remez Exchange(R.E.)algorithm.

  • PDF

Development of Vibration Motor Using Coreless Permanent Magnet DC Motor (무철심 영구자석 직류 모터를 이용한 진동자 개발)

  • Hwang, Sang-Moon;Chung, Shi-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.15-23
    • /
    • 1999
  • With a remarkable expansion of communication industry, a pager or a cellular phone becomes a necessary communication device in modern society. However, a paging signal by a buzzer is often acted as an unpleasant noise in some places, thus necessitating a paging signal by a vibration motor. In this paper, a simpler type of a vibration motor, a coreless permanent magnet(PM) DC motor, is considered to substitute for the conventional vibration motors. Using an analytical method, electromagnetic field and operating torque were calculated for the given inner and outer PM type motors, and the results were confirmed by FEM analysis. As design parameters, number of PM poles, PM radial thickness, coil arc angle and number of winding stacks were chosen for sensitivity analysis. It shows that coil arc angle is the most important design parameter to increase the motor performance, without giving an adverse effect on motor weight, size and manufacturing cost. Based on the analysis of the outer PM type motor, an outer square PM type motor is proposed as the final design. Compared to the outer PM type, outer square type provides more flexibility to attach to the small size cellular phones. With the optimum design of square outer PM DC motor, it can successfully substitute the conventional types with less expensive manufacturing cost. better performance and smaller necessary space.

  • PDF

A hardening model considering grain size effect for ion-irradiated polycrystals under nanoindentation

  • Liu, Kai;Long, Xiangyun;Li, Bochuan;Xiao, Xiazi;Jiang, Chao
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2960-2967
    • /
    • 2021
  • In this work, a new hardening model is proposed for the depth-dependent hardness of ion-irradiated polycrystals with obvious grain size effect. Dominant hardening mechanisms are addressed in the model, including the contribution of dislocations, irradiation-induced defects and grain boundaries. Two versions of the hardening model are compared, including the linear and square superposition models. A succinct parameter calibration method is modified to parametrize the models based on experimentally obtained hardness vs. indentation depth curves. It is noticed that both models can well characterize the experimental data of unirradiated polycrystals; whereas, the square superposition model performs better for ion-irradiated materials, therefore, the square superposition model is recommended. In addition, the new model separates the grain size effect from the dislocation hardening contribution, which makes the physical meaning of fitted parameters more rational when compared with existing hardness analysis models.

A Study on the Reduction of Entry Loss by Inner Structure in Square Hood in Industrial Ventilation System (산업환기시설에서 사각형 후드의 내부 설치에 의한 유입손실 감소에 관한 연구)

  • Bae, Hyun-Joo;Yang, Won-Ho;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.27-34
    • /
    • 2003
  • An objective of local exhaust hood design is to design the hood to operate as efficiently as possible. The greatest loss normally occurs at the entrance to the duct, due to the vena contracta in the throat of the duct. This can be accomplished by minimizing the loss that results from the vena contracta. There have been little studied to be cost-effective approach as installing simple instrument inside the throat of the hood. The aims of this paper were to minimize entry loss using inner square, and to measure the effect of inner square when installed inside hood throat. The results of this study were as follows; First, the magnitude of vena contracta could be considered as the difference between direct measured velocity and calculated velocity, which is from Bernoulli theory. In circle hood, calculated velocity and direct measured velocity were 10.7m/sec and 10.3n/sec, respectively. And the calculated velocity and direct measured velocity in square hood were 7.7m./sec and 6.5m/sec, respectively. Second, effect of inner square by width was carried out. The widths of inner square were L/1(18cm), L/2(9cm), L/3(6cm) and L/6(3cm). In case inner square was installed with 3cm width, the entry of coefficient was 0.93, comparing with 0.85 of entry of coefficient of general hood. Third, effect of inner square by distance from hood inside surface to inner square was carried out. The distances were L/3(6cm), L/6(3cm), L/9(2cm) and L/l8(1cm). In case the distance was 3cm the best efficiency was shown (Ce= 0.93). Fourth, effect of inner square by location from hood entry to duct inside was carried out. The locations of inner square were entry(0cm), L/6(3cm), L/3(6cm), L/2(9cm) and L/l(12cm). In case the location was 0cm, 3cm and 6cm the entry of coefficients were 0.93, 0.92 and 0.90, respectively.

A Study on the Planning for PC Use Space in Residences - Focus on the Unit Plan of Apartments According to the Size - (주거 내 PC 사용공간 계획에 관한 연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This study is aimed to provide a guide for PC use space in apartment. To achieve this, a design about PC use space which was considered adequate location, area, form was suggested. As methods of the study, survey research method and case study. The survey was taken by five hundred-eighty-nine people who used PCs in apartment from May 2005 to July 2005 in JeJu Special Self-governing Province for an analysis of data. The results of the survey were showed PC use space situation and furnitures layout patterns. The case was classified by unit plans of size, and it showed design example of PC use space. In types of $61{\sim}69$ square meters ($m^2$), PC use space was located in dead-space in the residence with minimum scale, because of $61{\sim}69$ square meters types are smaller than the other types. In types $100{\sim}129$ square meters, PC use space which was divided with a partition panel was located in the livingroom expanding the room space to the balcony. In types of 130 square meters, PC use space was located in the room of sons or daughters which was arranged with other furniture. The adequate area of PC use space is $1.4{\sim}2.2$ square meters, and it should take into account furniture size and human active sphere. And PC use space of form should consider traffic line, personal space and privacy. Besides it is required of ergonomic design in chair, table in its scale. And it is necessary development of systematic furniture for PC use space.

Earthquake-Induced Wall Pressure Response Analysis of a Square Steel Liquid Storage Tank (지진하중을 받는 정사각형 강재 액체저장탱크의 벽면 압력 응답 해석)

  • Yun, Jang Hyeok;Kang, Tae Won;Yang, Hyunik;Jeon, Jong-Su
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.5
    • /
    • pp.261-269
    • /
    • 2018
  • This study examines earthquake-induced sloshing effects on liquid storage tanks using computation fluid dynamics. To achieve this goal, this study selects an existing square steel tank tested by Seismic Simulation Test Center at Pusan National University as a case study. The model validation was firstly performed through the comparison of shaking table test data and simulated results for the water tank subjected to a harmonic excitation. For a realistic estimation of the wall pressure response of the water tank, three recorded earthquakes with similar peak ground acceleration are applied:1940 El Centro earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Wall pressures monitored during the dynamic analyses are examined and compared for different earthquake motions and monitoring points, using power spectrum density. Finally, the maximum dynamic pressure for three earthquakes is compared with the design pressure calculated from a seismic design code. Results indicated that the maximum pressure from the El Centro earthquake exceeds the design pressure although its peak ground acceleration is less than 0.4 g, which is the design acceleration. On the other hand, the maximum pressure due to two Korean earthquakes does not reach the design pressure. Thus, engineers should not consider only the peak ground acceleration when determining the design pressure of water tanks.