• Title/Summary/Keyword: Sprinklers

검색결과 52건 처리시간 0.023초

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.

  • PDF

국내 스프링클러 설치기준과 소방관련 법에 관한 고찰 (The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act)

  • 김용문;이영재
    • 한국방재안전학회논문집
    • /
    • 제7권2호
    • /
    • pp.17-24
    • /
    • 2014
  • 최근 들어 주택 및 집합건물에서 화재가 발생할 경우 스프링클러가 설치되어 있지 않거나, 설치되어 있어도 제대로 작동하지 않아서 많은 인명과 재산상의 손실을 초래하는 경우를 자주 목격하게 된다. 건축물 화재가 발생하면 초기에 진압하는 소화설비로써 가장 적합한 것은 스프링클러라 여겨진다. 하지만 국내의 경우 법체계의 미비로 인해 스프링클러 설비가 가진 본연의 성능을 발휘하지 못하고 있다. 우리나라 기준은 스프링클러 설비의 설치 대상을 업종과 건축물 형태에 따라 단순하게 분류하며, 건물의 용도나 건축물의 층수로 구분하고 있는 실정이다. 특히 층수가 11층 이상인 특정소방대상물에만 모든 층에 스프링클러를 설치하게 되어 있을 뿐, 법적으로 10층 이하의 건물에는 스프링클러를 설치하지 않아도 되는 안전의 사각지대에 놓여 있다. 본 연구에서는 스프링클러 설비에 관한 개념, 국내외 법체계상에서 규정하는 스프링클러의 설치기준, 그리고 근래에 발생한 화재사고에서 스프링클러 설치 및 관리기준의 허점으로 인해 피해를 키운 사례를 분석하여 그 원인과 시사점을 도출하였다. 결과적으로 국내의 경우 신축 건물에 대해서 층수에 관계없이 모든 집합건물은 스프링클러를 의무적으로 설치하게 하는 법 및 제도적 장치를 마련해야 한다. 또한 기존의 건축물 중에 스프링클러가 설치되어 있지 않은 건물의 경우에는 신규로 스프링클러를 설치하고자 하면, 정부 보조금을 지급하여 스프링클러 설치를 장려하는 정책적 시행도 요구된다. 더욱이 스프링클러의 설치적 기준의 강화뿐만 아니라 전문기술자격자에 의한 수시, 정기점검을 강화하는 등 스프링클러의 운용 및 유지에 대한 관리적 기준도 보완하여 화재 발생 시 소방 활동이 제대로 이루어지도록 해야 한다.

스프링클러 소방설비의 부식에 관한 연구 (A Study on Corrosion of Sprinklers System Fire Protection)

  • 김동준;고흥;남궁승태
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.41-48
    • /
    • 2008
  • We studied on corrosion of sprinklers system fire protection, a cause on corrosion of fire installations and a source of the problem. We investigated the influence of fluid mechanics on the corrosion shape of sprinklers system fire protection installations. And we known a problem of early fire extinguishing in fire protection with corrosion.

  • PDF

스프링클러 소화설비의 열감지에 관한 연구 (A study on the thermal reponsivenes of automatic sprinklers)

  • 손봉세
    • 방재기술
    • /
    • 통권10호
    • /
    • pp.9-12
    • /
    • 1991
  • As the present idustry is devolping rapidly, automatic sprinklers continue to play a key role in modern fire protection. But the technical basis and methods of measurement of the thermal response of sprinklers are not studying in our country. Therefore, the purpose of this paper is to analyze the thermal response characteristics and condition parameters of automatic sprinkler head.

  • PDF

자동 스프링클러로 보호된 창의 내화 성능 평가에 관한 연구 (The Evaluation of Fire Endurance of Glazing Systems with Automatic Sprinklers)

  • 이창섭;장석화;김홍;정기창
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1998년도 추계학술발표회 논문 초록집
    • /
    • pp.73-76
    • /
    • 1998
  • To use glazing systems protected by automatic sprinklers as fire barriers in building compartmentation, fire endurance tests of these systems have been performed by several research workers. Most of the tests concerned the types of glasses and sprinklers, sprinkler water flow rate, and sprinkler activation time. Horizontal side wall sprinklers and window glazing systems with a vertical center mullion were mainly applied in the tests. In the study, full-scale fire endurance tests were carried out to verify the ability of large glazing systems divided by a horizontal mullion and protected by pendent vertical sprinklers. The result shows that the protrusive length of the horizontal mullion, which is perpendicular to the glass surface, is the main parameter that determines the fire resistance rating of the systems. The mullion obstructs the water flow in the glass.

  • PDF

소방안전을 위한 독립 스프링클러 개발 (Development of Independent Sprinkler for Fire Safety)

  • 윤해룡;김선엽;김호찬;박인백
    • 한국기계가공학회지
    • /
    • 제16권2호
    • /
    • pp.124-128
    • /
    • 2017
  • Sprinklers are a necessary device for the early suppression of fires to prevent large fires. The installation has been obligatory for certain buildings recently through the digestion method. In an aging building, it is difficult to find sprinklers, because of their significant cost, long installation times, and they require installation by experts. That is why we are able to install all, was designed with enough independent integrated sprinklers with fire-extinguishing capabilities. The designed sprinklers are fitted with a conventional sprinkler head in a container of 20cm * 20cm * 10cm. Inside the container and potassium carbonate, which warms the rubber material and the plate line by pressing the potassium carbonate, the line weight is a 5kg pressing plate at the entrance at the pressure of 0.5Mpa when operating. The glass sprinkler valve blocking the entrance at about $68^{\circ}C$ is operated open. At this time, the potassium out of the digestive fire to combustible materials and heat off a chain reaction.

FIRES IN REAL SCENARIOS

  • Ghosh, B-K
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.439-449
    • /
    • 1997
  • Studies have been carried out to determine the effect of sprinklers on fires typical of a number of occupancies including simulated of office furniture, supermarkets, carpet displays, libraries, video stores and liquor stores. After surveys of actual fire loads, the experiments were conducted in a specially designed sprinklered fire-calorimeter with a collecting hood 6 m x6 m leading to a vertical duct 1 m in diameter. Details of the rig are given elsewhere [1]. Only well ventilated fires were studied. Rate of heat release and production of various toxic chemicals were monitored during the tests. Both sprinklered and unsprinklered fires were used. The results were used to establish the unsprinklered burning behaviour and the fire-control effects of sprinklers. Before sprinkler operation, the rate of fire growth could be modelled as 12_fires as given in NFPA 92B (1991 Edition) [2]. It was found that operation of sprirnklers controlled but did not extinguish the fires. This was expected as parts of the fire load were shielded from the spray. Also there were significant increases in the concentration of carbon monoxide when the sprinklers operated. Sprinklers had little effect on the concentrations of other toxic products measured. The results from the tests were extrapolated to large single storey buildings for the same occupancy classes and the results used to compare the required and the available escape times for different occupancies, particularly whether the use of sprinklers would improve the chances of escape from those premises. It was found that in most of the cases studied, adequate escape times will be available without any special measures. For very rapid fire growths, however, special measures, such as availability of trained staff may be needed. Standard response sprinklers will have little impact.

  • PDF

아파트 화재 사례 전산모사를 통한 화재위험성 평가에 관한 연구 (A Study for the Fire Hazard Evaluation through the Fire Simulation of an Apartment Fire Accident)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.69-78
    • /
    • 2010
  • 본 연구에서는 FDS 프로그램을 사용하여 아파트 화재 사고에 대한 전산모사를 통하여 화재위험성을 평가하였다. 화재 전산모사 결과, 스프링클러 미 작동 시 최대 열방출율은 7,700kW로써 스프링클러 작동시 최대 열방출율 497kW의 약 16배이며, 화재실의 문 강제 개방 시 역화현상의 발생으로 화재위험은 매우 높게 나타났다. 화재실 온도의 위험도래시간과 감지기 작동 시간에 의한 재실자 피난 여유시간은 최소 32.5초와 최대 53.5초이다. 스프링클러 작동 시에는 냉각에 의한 화재제어로 아파트 실내의 화재위험은 낮아짐을 알 수 있었다. 본 아파트 화재사고의 전산모사 결과를 통하여 소화설비 및 비상방송설비의 정상작동이 화재안전에 얼마나 중요한 역할을 하는지, 그리고 작동 불능 시 얼마나 큰 피해 손실을 초래하는지에 대하여 알 수 있었다.

스프링클러 설비투자의 경제적 효용성 분석에 관한 연구 (A Study on the Economic Utility Analysis of Sprinkler System Installation)

  • 김용달;최영화;윤명오
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.31-39
    • /
    • 2010
  • 우리나라는 선진국에 비하여 스프링클러설비 의무 설치대상이 다소 제한적인데도 불구하고 대부분의 건축물 소유주 또는 운영주체들은 법률에서 지정하고 있는 설치대상 건축물에 한해서만 설치하거나, 건축물 설계 시 스프링클러설비의 설치대상 기준에 해당되지 않도록 하는 경향이 있다. 이는 건축물의 화재 안전성 보다는 스프링클러설비 설치비용의 절감이 우선적이라고 생각하고 있기 때문으로 사료된다. 따라서 본 연구에서는 스프링클러설비를 설치하고 관리하는데 소요되는 제반 비용을 투자의 개념으로 하여 이로부터 얻을 수 있는 급부를 추정하였다. 결과적으로 스프링클러설비의 투자비용과 설치하였을 경우 얻을 수 있는 경제적 이득을 경제적 효용성 분석을 통하여 비교한 결과, 초기 투자비용 회수기간이 건축물의 내구연한의 약 1/20 수준으로 나타났으며 효용성도 비용의 2배 이상으로 나타났다. 따라서 스프링클러 설치는 경제적 효용성을 갖춘 제도로 볼 수 있어 적극적인 확대를 고려해 보는 것이 바람직할 것이다.

NFSC 103 스프링클러설비의 배관스케줄방식에 대한 제안 (A Proposal on the Pipe Schedule Sprinkler System of NFSC 103)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.40-47
    • /
    • 2014
  • NFSC103의 배관스케줄방식으로 설계하는 경우, 작동면적 내의 헤드 약 50%가 최소요구량에 못미치는 문제점을 해결하기 위하여 NFSC103과 NFPA13의 배관스케줄방식을 비교, 분석하였으며 NFSC103의 유량부족 문제를 해결할 수 있는 새로운 방법을 제시하였다. 각 헤드에서의 소화수방출량을 기존의 80 L/min의 150%인 120 L/min으로 하면 수리계산한 값을 상회하여 모든 헤드에서 최소기준값인 1 bar, 80 L/min을 충족하게 된다. 이는 누구나 쉽게 배관스케줄방식으로 설계할 수 있으며 설계면적 내의 모든 헤드가 최소요구량을 충족하는 최적의 방법이다.