• 제목/요약/키워드: Sprinkler systems

검색결과 61건 처리시간 0.024초

Non-bridge 형 미니스프링쿨러의 살수 특성 (Distribution Characteristics of a Mini -Sprinkler without a Bridge)

  • 이남호
    • 한국농공학회지
    • /
    • 제42권1호
    • /
    • pp.66-72
    • /
    • 2000
  • A study was conducted to find distribution patterns of minisprinkler without a bridge for the desing of microirrigation systems. The experiments were executed in a plastic house to minimize the effect of the wind. Data were collected at four different operation pressures and at 3 different riser heights. Sprayed water were collected by aluminium cans with 65mm diameter and 100mm height placed at 0.3m grid spacing . A schematic distribution pattern with distance from a minisprinkler was suggested for the layout design of the minisprinkler. Distribution pattern of the minisprinkler was found irregular in space. Distributin performance characteristics of the minisprinkler such as effective radius. , effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. It was indicated that there is a trend of decrease in variation coefficient adn better water distribution by the increase in operation pressures and riser heights.

  • PDF

수성막포 약제를 첨가한 미분무수의 식용유 화재 소화특성 (Extinguishing Characteristics of Cooking Oil Fire by Water Mist added with AFFF Agent)

  • 신창섭;김성룡
    • 한국안전학회지
    • /
    • 제24권5호
    • /
    • pp.21-27
    • /
    • 2009
  • Effective way of cooking oil fire extinguishment is using water mist system which has cooling and smothering effects. Low pressure water mist system has advantage because it is compatible with existing sprinkler systems. To increase the effectiveness of low pressure water mist system, additives can be used which increase the momentum of water particle and the chemical effect. In this experiment, aqueous film forming form(AFFF) agent is used as additive and the effect of additive concentration and water pressure are experimented. For the extinguishment of cooking oil fire such as soybean and olive oils, AFFF agent is effective and can decrease the fire extinguishing time and water consumption.

환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구 (A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities)

  • 전용한;한상필
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

Control of RC-Helicopter by Using Fuzzy Sliding Mode Controller

  • Hiramatsu, Tomoyasu;Miyazaki, Michio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.210-214
    • /
    • 1998
  • Radio-Controlled helicopter has superior movement abilities like as hovering or backward move. So it has been used as a sprinkler of agricultural medicines or an observer of dangerous area such as a volcano, etc. But its operation is not simple because it has many control factors and they interfere with each other. Therefore the helicopter is not controlled by simple theory in the case of automatic operation. Then fuzzy sliding mode control, which has fastness, fineness and robustness, is thought to be suitable to satisfy various requirements of the helicopter operation. In this work, the fuzzy sliding mode control was applied to the flying of RC helicopter, As tile result, it was controlled with good performance.

  • PDF

Long Jet Monitor의 소화수 분사 거리에 대한 유동 해석적 연구 (A Study of Computational Fluid Dynamics Analysis for the Water Spray Distance of Long Jet Monitor)

  • 조재상
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.907-913
    • /
    • 2023
  • Currently, the sprinkler method is widely used as an initial suppression method in existing firefighting systems. However, this method can cause significant damage to both equipment and facilities in the hydration area. To minimize this damage, fire extinguishing monitors are being developed that can spray fire extinguishing water directly at the point of fire. These monitors are installed on the top floor of the ship, such as the Living Quarter and Ventilation System. While conventional fire extinguishing monitors focus on lightweight research with a short spray port and require a spray distance of about 40 to 45m, recent developments necessitate a longer spray port, similar to a water cannon, requiring a spray distance of about 70 to 75m. This study aims to predict the injection distance of both the existing ship-installed fire extinguisher and the long spray port fire extinguisher through hydrodynamic computer analysis, and to determine whether the injection distance has increased.

LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구 (A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process)

  • 손봉세;장찬희
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.41-47
    • /
    • 2012
  • 첨단산업기술인 반도체, LCD 등 제조의 핵심공정인 클린룸은 생산제품의 성능 및 품질에 절대적인 영향을 미치는 가장 중요한 공정이다. 그러나 국내는 방화공학적인 측면에서 과학적이고 종합안전대책에 대한 체계적인 연구가 제대로 이루어지지 않고 있다. 본 연구는 LCD 제조공정 클린룸에 설치하는 제연시스템의 성능 및 문제점을 파악하여 이에 대한 개선방안을 도출하기 위하여 여러 시나리오를 고려한 화재시뮬레이션과 피난시뮬레이션을 통하여 분석하였다. LCD 제조공정의 클린룸 화재 및 연기확산에 대하여 분석한 결과 화재시 공조기의 연동정지는 반드시 필요하며 연기의 부력을 고려하여 FAB 상부에 배연을 할 수 있도록 하여야 한다. 또한 대규모 클린룸의 경우 화재특성상 스프링클러헤드의 집열 성능이 떨어지므로, 조기반응형 헤드의 설치 및 작동시간을 빠르게 하기 위한 보조장치를 설치하여야 한다. 특히, 대공간 클린룸은 자동화 공정으로 거주밀도가 낮지만, 복잡한 생산장비의 배치와 방진복을 착용하고 근무해야하는 환경특성 때문에 화재시 피난안전성능 확보가 어렵기 때문에 공정 내 위험요소의 철저한 관리 및 주기적인 교육과 훈련이 필요하며, 방재선진국의 기준에 준하는 수준의 국내 관련기술 기준을 정립할 필요가 있다.

난지형 마늘의 농업수리학적 재배적지 분류 (Water Balance-based Farmland Suitability for Southern-type Garlic Cultivation)

  • 김용완;홍석영;김이현;장민원
    • 한국농공학회논문집
    • /
    • 제54권6호
    • /
    • pp.19-28
    • /
    • 2012
  • This study carried out farmland suitability analysis for southern-type garlic cultivation considering soil and temperature as well as water deficit conditions. The spatial extent was limited within the area derived by Kim et al. (2012) using just soil and temperature constraints. Daily soil moisture was simulated using a one-layer soil water balance model at a $100{\times}100m$ grid unit, and then annual water deficit was calculated from 2000 to 2010. The farmland suitability was classified as four steps: best suitable, suitable, possible, and low productive. As a result, total area of best suitable or suitable farmland was about 375,900 ha, and Gimje-si and Haenam-gun were appeared as the largest favorable area for southern-type garlic cultivation. The best suitable or suitable area at Haenam-gun, Goheung-gun, Shinan-gun, Namhae-gun, and Muan-gun, major production regions of southern-type garlic, were extracted as 20,187 ha, 13,018 ha, 4,715 ha, 1,319 ha, and 349 ha, respectively. On the other hand, the result showed that the adoption of sprinkler irrigation systems might be critical in cultivating the southern-type garlic at some regions having poor water balance.

수계 파이프 시스템의 내진설계에 관한 연구 (A Study on the Seismic Design for Water Exthinguishing Piping Systems)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.10-15
    • /
    • 2008
  • 본 연구에서는 수계 시스템 중 스프링클러 헤드 파이프라인에 대한 내진설계를 수행하였다. 내진해석에 필요한 내진설계용 스펙트럼에 대응하는 인공지진 진동파형을 작성하고, 작성된 인공지진 진동에 대한 동적 응답스펙트럼을 해석하였다. 내진설계를 위한 공학적 기반을 구축하였으며, 수계 및 가스계 파이프 시스템의 내진설계 기법을 제시하였다. 또한 본 연구의 결과로부터 수계 시스템의 파이프라인뿐만 아니라 소방시스템의 내진설계 및 성능평가에 응용할 수 있는 기틀을 마련하였다. 향후 진도규모 및 지반종류에 따른 추가적인 연구가 수행된다면 소방시스템의 신뢰성 향상과 안전성 제고, 성능위주설계가 이루어질 수 있을 것으로 본다.

공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구 (A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses)

  • 김학경;최두찬;이두희;황현수;김희문
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.38-50
    • /
    • 2022
  • 연구목적: 본 연구는 방화관리자 및 건물 관계인이 피난안전성능 향상 계획 수립 시, 한정된 예산을 고려하여 피난안전성능 개선 항목 선정에 도움을 주는 수치해석 DB 구축 방향 수립이 목적이다. 연구방법: 직통계단형 아파트 1개동과 복도형 1개동을 선정하여 정량적 평가기법인 CFD기반 피난안전성평가를 수행하였다. 연구결과: 직통계단형 아파트는 방화구획 항목에서의 피난허용시간이 스프링클러설비 등 피난허용시간보다 약 130%이상 높게 나타났다. 결론: 방화관리자 및 건축물 관계인은 적법하게 유지관리하고 직통계단형 공동주택에서는 "주거세대 별도 방화구획"을 우선 적용하는 것이 피난안전성이 가장 개선되고, 층간 방화구획과 스프링클러설비를 상시 유지보수 및 강화하는 것이 효과적일 것으로 판단된다. 복도형 공동주택에서는 연기확산이 직통계단형 공동주택보다 제한적인 특성을 고려하여 소화설비의 유지보수가 우선되어야 할 것으로 사료된다.

분재(盆栽)의 대량재배(大量栽培)를 위한 관수(灌水)시스템과 관리방법(管理方法)의 개발(開發) (Development of Bottom Irrigation System and Management Method for Cultivation of Bonsai)

  • 이기의;정진형
    • Journal of Forest and Environmental Science
    • /
    • 제19권1호
    • /
    • pp.48-68
    • /
    • 2003
  • 현재 분재재배의 큰 문제점은 높은 노동력에 비해 생산성이 매우 낮은 것이다 본 연구는 관수시스템과 관리방법의 개발로 고품질의 분재를 대량생산하기 위해 실시되었다. FRP분상에서 재배된 분재는 직수관수나 스프링클러 관수에 비해 저변관수시스템에서 생육이 매우 좋았다. 또한 저면관수시스템은 노동력을 크게 줄일 수 있었고 짧은 기간에 대량생산을 할 수 있었다. 또한 비닐하우스내(內)에서 저면관수 시스템의 이용은 조기생산은 물론 고품질의 분재를 생산할 수 있었으며 내한성이 약한 수종들도 겨울재배가 가능하였다. 본 연구는 세계시장을 위한 국가경쟁력에 크게 기여하였을 뿐만 아니라 농가 수익에도 큰 도움을 줄 수 있었다.

  • PDF