• Title/Summary/Keyword: Spread system

Search Result 2,359, Processing Time 0.026 seconds

An Experimental Study on the Influence of the Spread of Firebrand on Building Exterior Materials and Roofing Materials in Urban Areas (도심지 인접 산불의 불티 확산이 건축물 외장재와 지붕재에 미치는 영향에 관한 실험적 연구)

  • Min, Jeong-Ki
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.617-626
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the fire srpead risk of building exterior and roofing materials due to the firebrand of forest fire occurring in the urban areas. Method: In order to achieve this research purpose, by selecting building materials used for exterior and roofing materials of buildings, the time to ignition, total heat release, and heat release rate were investigated, and a forest fire firebrand system was established to the possibility of fire spread was confirmed. Result: As a result of the cone calorimeter test, the roofing material had a similar or faster ignition time due to radiant heat compared to the exterior material with the steel plate exposed to the outside, and showed a higher heat release rate and total heat release than the exterior material. Although it was affected by the flammable material, it was confirmed that it did not spread easily due to the limited amount of combustible material, and carbonization marks appeared inside. Conclusion: The cone calorimeter test method has been shown to be useful in understanding the combustion characteristics of building materials by radiant heat, but the fire spread due to a firebrand in a forest fire is directly affected by the flame due to the ignition of surrounding combustibles, so finding a direct correlation with the cone calorimeter method is difficult. It is judged that the roof material may be more vulnerable to the spread of fire due to the fire than the exterior material.

Delay Spread Measurement and Analysis in 3 GHz and 6 GHz Indoor Environments (3 GHz, 6 GHz 실내 환경의 지연 확산 측정 및 분석)

  • Lee, Seong-Hun;Lee, Hwa-Choon;Cho, Byung-Lok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.15-20
    • /
    • 2020
  • In this paper, delay diffusion for exhibition hall and conference room was measured and analyzed in the indoor environment of the building. Scenarios for the indoor environment of the two buildings were written. also, the system configuration and measurement methods were conducted under the same conditions. The measurement conditions were set to 3 GHz and 6 GHz of center frequencies and analysis band selected 2 GHz. The measurement system consisted of vector network analyzer, power amplifier, omni-directional transmit and receive antenna, and transmission line. According to the indoor environment scenario of the two buildings, the location of the receiving antenna was divided into three zones based on the location of the transmitting antenna and this was measured at 1 m intervals according to 18 locations. The power delay profiles, RMS delay spread, and K-factor results of two buildings were compared and analyzed.

Design of digital communication systems using DCSK chaotic modulation (DCSK 카오스 변조를 이용한 디지털 통신 시스템의 설계)

  • Jang, Eun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.565-570
    • /
    • 2015
  • Spread spectrum communications have increased interest due to their immunity to channel fading and low probability of intercept. One of the limitations of the traditional digital spread spectrum systems is the need for spreading code synchronization. Chaotic communication is the analogue alternative of digital spread spectrum systems beside some extra features like simple transceiver structures. In this paper, This paper was used instead of the digital modulation and demodulation carriers for use in the chaotic signal in a digital communication system among the chaotic modulation schemes, the Differential Chaos Shift Keying(DCSK) is the most efficient one because its demodulator detects the data without the need to chaotic signal phase recovery. Also Implementation of Differential Chaos Shift Keying Communication System Using Matlab/Simulink and the receiver con decode the binary information sent by the transmitter, performance curves of DCSK are given in terms of bit-error probability versus signal to noise ratio with spreading factor as a parameter and we compare it to BPSK modulation.

A Digital Auto-Focusing Algorithm Using Point spread function Estimation Image Restoration (초점불완전 열화추정 및 영상복원기법을 사용한 자동초점시스템)

  • Kim, Sang-Ku;Park, Sang-Rae;Paik, Joon-Ki
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.57-62
    • /
    • 1999
  • Estimation of the point spread function (PSF) is one of the main research topic of image processing, because it determines the performance of the auto-focusing system. In this paper, a new algorithm for PSF estimation is proposed, and its application to image restoration is also presented. The procedure for complete realization of the auto-focusing system consists of two steps: PSF estimation based on edge classification, and image restoration using the estimated PSF. More specifically, we divide imput image into multiple small image or block, estimate unit step response and average them on the blocks which contain edge, and estimate 2-dimensional isotropic PSF from the 1 dimensional step response. Finally we obtain in-focused image by using image restoration based on the estimated PSF.

  • PDF

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

Dynamic Control of Random Constant Spreading Worm using Depth Distribution Characteristics

  • No, Byung-Gyu;Park, Doo-Soon;Hong, Min;Lee, Hwa-Min;Park, Yoon-Sok
    • Journal of Information Processing Systems
    • /
    • v.5 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • Ever since the network-based malicious code commonly known as a 'worm' surfaced in the early part of the 1980's, its prevalence has grown more and more. The RCS (Random Constant Spreading) worm has become a dominant, malicious virus in recent computer networking circles. The worm retards the availability of an overall network by exhausting resources such as CPU capacity, network peripherals and transfer bandwidth, causing damage to an uninfected system as well as an infected system. The generation and spreading cycle of these worms progress rapidly. The existing studies to counter malicious code have studied the Microscopic Model for detecting worm generation based on some specific pattern or sign of attack, thus preventing its spread by countering the worm directly on detection. However, due to zero-day threat actualization, rapid spreading of the RCS worm and reduction of survival time, securing a security model to ensure the survivability of the network became an urgent problem that the existing solution-oriented security measures did not address. This paper analyzes the recently studied efficient dynamic network. Essentially, this paper suggests a model that dynamically controls the RCS worm using the characteristics of Power-Law and depth distribution of the delivery node, which is commonly seen in preferential growth networks. Moreover, we suggest a model that dynamically controls the spread of the worm using information about the depth distribution of delivery. We also verified via simulation that the load for each node was minimized at an optimal depth to effectively restrain the spread of the worm.

Comparison of Fatigue Damage Models of Spread Mooring Line for Floating Type Offshore Plant (부유식 해양플랜트 다점 계류라인의 피로손상모델 비교)

  • Park, Jun-Bum;Kim, Kookhyun;Kim, Kyung-Su;Ko, Dae-Eun
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.63-69
    • /
    • 2013
  • The mooring lines of a floating type offshore plant are known to show wide banded and bimodal responses. These phenomena come from a combination of low and high frequency random load components, which are derived from the drift-restoring motion characteristic and wind- sea, respectively. In this study, fatigue models were applied to predict the fatigue damage of mooring lines under those loads, and the result were compared. For this purpose, seven different fatigue damage prediction models were reviewed, including mathematical formula. A FPSO (floating, production, storage, and offloading) with a $4{\times}4$ spread catenary mooring system was selected as a numerical model, which was already installed at an offshore area of West Africa. Four load cases with different combinations of wave and wind spectra were considered, and the fatigue damage to each mooring line was estimated. The rain flow fatigue damage for the time process of the mooring tension response was compared with the results estimated by all the fatigue damage prediction models. The results showed that both Benasciutti-Tovo and JB models could most accurately predict wide banded bimodal fatigue damage to a mooring system.

A Study on a Multi Location Awareness Base on CSS(Chirp Spread Spectrum) (CSS기반 다중 위치인식 시스템에 관한 연구)

  • Yang, Jin-Uk;Cho, Seung-Soo;Yang, Seung-Hyun;Kang, Jun-Gil
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.106-121
    • /
    • 2008
  • In this paper, we proposed and designed the protocol for energy efficiency and the center of data aiming at the design of a Multi Location Awareness System that recognizes a shadow site in parking and tunnel, which stands on the basis of CSS(Chirp Spread Spectrum) method using ISM Band of IEEE 802.15.4a that aware close location with wireless RF only. As a result of the protocol measurement, it displays the observation errors of less than 15cm, the data error rate of less than 5%, and can implement the Multi Location Awareness System with maximum length of life for 13.5 days using battery of 3V(1500 mAh).

  • PDF

SLURRY UTILIZATION SYSTEM IN THE PADDY FIELD

  • I. H. Oh;Kim, K.D.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.784-791
    • /
    • 2000
  • To improve the uniformity of slurry spreading and to reduce the odor problem, a hose slurry spreader was developed, which spread the slurry near to the surface of the soil. First, the uniformity of slurry spreading was investigated. The best result of 8.1 % CV was obtained at the rotor speed of 250 rpm than any other speeds for the swine slurry, which contains 13.6% of dry matter. In case of dairy cattle slurry, which contains 8.2% of dry matter, the uniformity has the best result of CV 7.2% by high rotor speed of 330 rpm. A high speed of rotor has built a sufficient pressure in the distributor and discharged a uniform quantity of slurry through the hoses. Therefore, in practical use one should work with rotor speed over 300 rpm to maximize the uniformity of slurry spreading. Second, odor test was done with the swine slurry. While the conventional spreader shows ∑ value 440, the hose slurry spreader and its combination of disk harrow show ∑ value 258 and 184 respectively. With the air dilution sensual test and a 3-point odor bag, the conventional spreader shows 66.9 or 35.4 point and by the hose slurry spreader is 9.7 or 11.1 point. So, the developed spreader was found to have a greater effect on the reduction of odor problem. Finally, it is recommended to spread certain amount of the slurry for paddy field equivalent to the chemical fertilizer based on the N-content. It means 22 tons of swine slurry per ha. Since most of the livestock farms possess less arable land, a system of linking farms is necessary to utilize the slurry crossover the farms. The cost of slurry utilization including filling, transport spreading and brokerage is 3200-6800 Won/㎥ in accordance with the transport distance.

  • PDF

Nomenclature and Lymphatic Drainage Patterns of Abdominal Lymph Nodes (복부 림프절의 명명법 및 림프 배액 패턴)

  • Hyun Seok Cho;Jhii-Hyun Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1240-1258
    • /
    • 2022
  • The lymphatic system provides a route for the spread of inflammation and malignancies. The identification of nodal stations and lymphatic pathways of tumor spread is important for tumor staging, choice of therapy, and the prediction of the prognosis of patients with malignant diseases. Because lymph node metastasis is common in primary intra-abdominal malignant tumors, its detection is essential for radiologists to understand the pattern of disease spread. Using schematic pictures and color-coded CT images, this pictorial essay describes the locations and nomenclature of the abdominal lymph nodes. Furthermore, the lymphatic drainage pathways of the upper and lower gastrointestinal tracts, liver, gallbladder, bile duct, and pancreas have been highlighted. In addition, lymph nodes belonging to the regional lymph nodes in malignant tumors arising from each organ are described, and certain cases are presented with images from patients.