• 제목/요약/키워드: Spraying condition

검색결과 149건 처리시간 0.031초

Effects of Process Parameters on the Coating Properties of APS TiO2 ioceramic Coatings

  • Kim, Hak-Kwak;Jang, Ju-Woong;Kim, Byoung-Soo;Moon, Ji-Woong;Lee, Deuk-Yong;Lee, Chang-Hee
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.123-127
    • /
    • 2003
  • The effects of process parameters on coating formation and coating properties were investigated using a fused and crushed Ti $O_2$powder by the Taguchi method and L$_{9}$(3$^4$) orthogonal array. The Taguchi analysis was conducted through the results of the coating properties affected strongly by plasma spraying parameters and Ti $O_2$powder was sprayed on Ti-6Al-4V alloy substrate. The coating properties were characterized by thickness, microhardness, porosity and surface roughness using optical microscopy, image analyzer and surface roughness tester respectively. An observed optimum condition of plasma spraying process could be found for potential use as a bioceramic coating.

GT-96 멤브레인형 LNGC의 급냉기간에서의 열해석 (Thermal Analysis for the GT-96 Membrane Type LNGC during the Cool-down Period)

  • 이정혜;최현규;최순호;오철;김명환;김경근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1346-1351
    • /
    • 2004
  • This study is concerned with the thermal analysis during the cool-down period of 135,000 $m^3$ class GT-96 membrane type LNG carrier under IMO design condition. The cool-down is performed to cool the insulation wall and the natural gas in cargo tank for six hours to avoid the thermal shock at the start of loading of $-163^{\circ}C$ LNG. During the cool-down period, the spraying rate for the NG cooling decreases as the temperature of NG falls clown from $-40^{\circ}C$ to $-130^{\circ}C$ and the spraying rate for the insulation wall cooling increases as the temperature gradient of the insulation wall is large. It was confirmed that there existed the largest temperature decrease at the 1 st barrier and 1st insulation, which are among the insulation wall, especially in the top side of the insulation wall. By the 3-D numerical calculation about the cargo tank and the cofferdam during the cool-down period, the temperature variation in hulls and insulations is precisely predicted.

  • PDF

기상조건별 비산먼지 관리체계 최적화 연구 (Optimization of Fugitive Dust Control System for Meteorological Conditions)

  • 김현구
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.573-583
    • /
    • 2005
  • Fugitive dust, which is emitted in the ambient air without first passing through a stack or duct designed to control flow, is frequently generated by means of wind erosion from storage yards at Pohang Steel Wokrs. The size distribution of fugitive dust is mostly in the range of coarse particulate which is deposited as soon as emitted and less harm to human health; however $20\%$ of fugitive dust contains PM 10 known as one of most harmful airborne pollutant. Consequently, effective control and reduction of fugitive dust is strongly requested by the local society, but it is not easy so far because the generation and dispersion of fugitive dust highly depends on meteorological conditions, and it being occurred for irregularity. This research presented a fugitive dust control system for each meteorological condition by providing statistical prediction data obtained from a statistical analysis on the probability of generating the threshold velocity at which the fugitive dust begins to occur, and the frequency occurring by season and by time of the wind direction that can generate atmospheric pollution when the dispersed dust spreads to adjacent residential areas. The research also built a fugitive dust detection system which monitors the weather conditions surrounding storage yards and the changes in air quality on a real-time basis and issues a warning message by identifying a situation where the fugitive dust disperses outside the site boundary line so that appropriate measures can be taken on a timely basis. Furthermore, in respect to the spraying of water to prevent the generation of fugitive dust from the storage piles at the storage yard, an advanced statistical meteorological analysis on the weather conditions in Pohang area and a case study of fugitive dust dispersion toward outside of working field during $2002\∼2003$ were carried out in order to decide an optimal water-spraying time and the number of spraying that can prevent the origin of fugitive dust emission. The results of this research are expected to create extremely significant effects in improving surrounding environment through actual reduction of the fugitive dust produced from the storage yard of Pohang Steel Works by providing a high-tech warning system capable of constantly monitoring the leakage of fugitive dust and water-spray guidance that can maximize the water-spraying effects.

주행속도 보상형 붐방제기의 개발 (Development of a Flow Compensating Boom Sprayer for the Speed Variation)

  • 구영모;정재은
    • Journal of Biosystems Engineering
    • /
    • 제23권3호
    • /
    • pp.211-218
    • /
    • 1998
  • A variable flow-controlled boom sprayer was developed and evaluated. Field tests were conducted to evaluate the adoptability of the sprayerr with optimal conditions. Negative response time was obtained from the field test because pump and PTO were interlocked with the speed of sprayer. Another reason for the negative value was due to the definition of the response time. With constant on-time control, the system was unstable at the conditions of small tolerance and long control interval. The performances of the spray system were stable and accurate. The stable and synchronous responses were achieved with a variable on-time control. The flow control system with an optimal condition (1.0 sec of control interval, 2 of damping ratio, 1% of tolerance) provided the proper performance for uniform spraying. A standard operating procedure of the flow compensating boom sprayer for the ground speed variation was presented and recommended.

  • PDF

Agglomeration of Barium Titanyl Oxalate Tetrahydrate

  • Park, Zee-Hun;Shin, Hyo-Soon
    • The Korean Journal of Ceramics
    • /
    • 제1권2호
    • /
    • pp.69-74
    • /
    • 1995
  • The optimal condition for minimal agglomeration of barium titanyl oxalate tetrahydrate, the precipitate on preparing barium titanate by oxalate process, was investigated. Burette-dropping and dual-nozzle-spraying were used as adding methods. pH of washing water for precipitates was changed, and sodium pyrophosphate solution, methanol, ethoanol, and acetone were used as washing agents for precipitates, as well as distilled water. Drying temperature was changed from $50^{\circ}C$ to $120^{\circ}C$. Spraying, methanol-washing, and drying at $60^{\circ}C$ showed the most dispersed distribution, Below $70^{\circ}C$, the crystalline phases were observed.

  • PDF

Particle Deposition, PD Process - New Potential in Material Processing -

  • Fukumoto, Masahiro
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.47-48
    • /
    • 2006
  • Oridinal thermal spray process has developed into two ways, namely, temperature dominated represented by plasma spraying, and velocity dominated represented by HVOF. It is common for both that the particle materials sprayed are basically in melted or half melted condition. New process has developed recently, that is, Cold Spray and Aerosol Deposition. Particle's heating is limited in CS lower than half of the material's melting point. Moreover, exactly no heating is loaded in AD process. Through the investigation on common feature for these three spraying processes, potential of new material process - Particle Deposition, PD - is considered and proposed.

  • PDF

미세입자 분사가공 시 표면 조건 변화에 따른 가공 표면 형상 분석 (Analysis of Machined Surface Morphology According to Changes of Surface Condition in Micro Particle Blasting)

  • 최성윤;황철웅;권대규
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.70-75
    • /
    • 2018
  • This study analyzes the change of Al 6061-T6 specimen surface shape when undergoing microparticle spraying and analyzes the influence of factors on the experiment. Fine particle spraying is applied to the specimen and the surface shape of the processed surface is measured through a surface shape measuring device. The measured data was analyzed by the ANOVA method to investigate the effect of factors such as particle, nozzle diameter, pressure, injection height, and injection time on the injection depth and injection diameter.

아크 금속 용사 표면 처리 방법에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가 (Evaluation of physical properties of Zn-Al metal coating according to arc metal spray surface treatment method)

  • 장종민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2022
  • Arc metal spraying is a widely used method for improving the performance of construction structures such as corrosion resistance and electromagnetic wave shielding. However, when arc metal spraying is applied to a concrete structure, adhesion performance may deteriorate. Therefore, the effect of each surface treatment method on the physical properties between the arc metal spray coating and concrete was reviewed by evaluating the deposition efficiency and adhesion performance according to the arc metal spray surface treatment method (surface reinforcing agent, roughening agent, and sealing agent). As a result, it is suggested as an optimal surface treatment condition to induce non-interface failure by using a roughening agent and to improve the properties of concrete and metal coatings by applying a surface reinforcing agent and sealing agent.

  • PDF

농약방제복 착용실태 및 만족도에 관한 연구 (A Study on the Wearing Condition and Satisfaction of Pesticide Protective Clothing)

  • 오영순;이경숙;채혜선;김경란;김성우
    • 한국의상디자인학회지
    • /
    • 제16권4호
    • /
    • pp.217-228
    • /
    • 2014
  • The purpose of this study is to grasp inconveniences and improvements by examining wearing condition and satisfaction of protective clothing targeting 114 Korean farmers and to suggest basic data for enhancement of pattern and wearing satisfaction of protective clothing by understanding problems of pesticide-proof clothing through comparative analysis on the size of its commercial products. Most of male subjects were in charge of spraying pesticide, whereas female were most likely to play an assistant role to hold the hose of pesticide applicator. Both of female and male subjects were very aware of the harmful effect of pesticide on human body and tried to take off the clothes immediately after spraying it to reduce possible damage caused by pesticide. As a result of examining wearing condition, the farmers avoided wearing protective clothing because that it feels hot, stuffy, and uncomfortable to move. This hesitant response of wearing the clothing was not shown significantly in case of female subjects who play an assistant role for spraying. Although the farmers wore protective equipments such as mask or gloves in a proper way as compared to protective clothing, they seemed to choose alternative way rather than best way to block pesticide completely. The satisfaction regarding to the fitting of protective clothing which the subjects showed low in all items of upper-lower clothes except waistline. It is necessary to improve the functionality such as relief from heat stress and convenience for movement rather than design or economic in protective clothing development. As a result of comparing the size of five kinds of commercial protective clothing, the farmers got confused to choose the product since designation method of size across companies showed a significant difference in an identical clothing size. In addition, the sizing system developed on a basis of a well-built man has become a hindering factor in wearing satisfaction of female farmers.

  • PDF