• Title/Summary/Keyword: Sprayed

Search Result 1,365, Processing Time 0.028 seconds

Influence of CrO3 Sealing Treatment on Properties of Plasma Sprayed Al2O3 Coating (플라즈마 용사 Al2O3 코팅의 특성에 미치는 CrO3 봉공처리의 영향)

  • Cho, Kyeong-Sik;Lee, Hyun-Kwuon;Kwon, Jeong-Cheol
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.2
    • /
    • pp.160-167
    • /
    • 2011
  • Plasma sprayed ceramic coatings inherently contain pores and usually also cracks. Post-treatment of the plasma sprayed coatings is a way to close the connected pores and cracks. In this study, post-sealing treatment in plasma sprayed $Al_2O_3$ coatings was employed to overcome the reduction of coating properties. $Al_2O_3$ plasma thermal spray coating was made on aluminum alloys plate, $CrO_3$ post coating and heat treatment at $550^{\circ}C$ was carried out in order for final $Cr_2O_3$ to be saturated through phase transformation. Chromia sealing began at the fine defect in coated microstructure, while larger pores were permeated later. The increase in concentration and treatment frequency of sealing solution resulted in the decrease of porosity of coating layer, while cracks occurred partially after the third treatment. After twice treatment of 10M $CrO_3$ solution, microhardness and breakdown voltage of $Al_2O_3$ coatings were found to increase by ${\fallingdotseq}$ 50% and ${\fallingdotseq}$ 390% respectively than without post-treatment.

Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance (내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가)

  • Won, Jong-Pil;Choi, Seok-Won;Park, Chan-Gi;Park, Hae-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.559-568
    • /
    • 2006
  • The purpose of this study is to evaluate the mechanical performance and fire resistance of wet-mixed high strength sprayed polymer-modified mortar in order to protect tunnel lining system which are in the event of fire disaster. Since the current commercial fire-resistant materials reproduce the low strength issue of mortar, this study aims to provide an enhanced fire-resistant mortar with a proper strength. Normally, a large temperature gradient phenomenon arise in the vicinity of free surfaces which are fully exposed in the event of persistent flame. Thereby, the determination of optimal cover depth of wet-mixed high strength sprayed polymer-mortar(WHSPM) is important for fire-resistance of tunnel lining system. With comparison of current commercial fire-resistance materials and WHSPM, the experimental result of WHSPM shows the better fire-resistant performance than the others. In addition, the cover limitation should be controlled by minimum 4cm depth in order to avoid fire-induced damage.

Weathering Performance Evaluation of Duplex Coating Systems of Thermal Spraying and Painting using Corrosion Test (부식실험에 의한 금속용사와 도장의 복합피복방식법의 내후성능평가)

  • Kim, In Tae;Kim, Ho Seob;Kien, Dao Duy;Jun, Je Hyeong;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.97-108
    • /
    • 2016
  • Thermally sprayed metals or organic coatings is often used in corrosion protection of steel structures. Duplex coating systems of thermally sprayed metal in combination with organic coating are selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, three types of corrosion tests were carried out on four types of thermal sprayed specimens with sealing: zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, four types of duplex coated specimens; thermally sprayed metals in combination with paint of acrylic urethane, and painted specimens. NORSOK M-501, Wet/dry cyclic seawater tests and outdoor exposure tests of nine types of specimens were conducted. From the corrosion test results, weathering performance of them were presented.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.

SOFT TISSUE RESPONSE TO THE PULSED Nd : YAG LASED DENTAL IMPLANTS IN THE RABBIT ABDOMINAL WALL (Pulsed Nd : YAG 레이저를 조사한 임플란트를 가토복강내에 이식시 주위조직에 미치는 영향)

  • Jun, Joong-Hyun;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.800-815
    • /
    • 1996
  • Pulsed Nd : YAG laser has been used to treat various soft tissue lesions. However, there have been warnings of using laser to treat peri-implantitis because the laser can alter the surface of implant and can rise its temperature so that it might be harmful to implant itself and its surrounding tissue. However, the study in vivo has not been done yet. The purpose of this study was to evaluate the biocompatibility to the pulsed Nd:YAG lased dental implant. 16 HA coated implants and 16 titanium plasma sprayed implants were used. They were divided 4 groups as unlased control, 0.3 watt, 1.0 watt and 2.0 watt lased groups after lasing. And they were implanted in the peritonial walls of 12 rabbits. The rabbits were sacrificed 6 weeks after implantation and the LM and EM specimems were made. 1. In the unlased implant group, both HA coated and titanium plasma sprayed implants were surrounded by fibroblasts and collagen fibers. No macrophages and inflammatory cells were seen. 2. In HA coated implants 0.3 watt, 1.0 watt lased group had a little inflammation, but in 2.0 watt lased group had scattered macrophages, a significantly larger number of chronic imflammatory cells were seen. 3. In titanium plasma sprayed implant 0.3 watt, 1.0 watt lased group had a little inflammation, but in 2.0 watt group had severe inflammation as in the conditions of HA coated group. 4. The inflammatory reaction of both lased HA coated and titanium plasma sprayed implant groups increased as the increase of the power of the laser.

  • PDF

Scanning Electron Microscopic Study of the Effects of Citric Acid on the Change of Implant Surface According to Application Time (구연산의 적용시간에 따른 임플란트 표면변화에 대한 주사전자현미경적 연구)

  • Song, Woo-Seok;Kwon, Young-Hyuk;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.697-709
    • /
    • 2002
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, titanium plasma-sprayed surface, and sand-blasted, large grit, acid etched surface were utilized. Implant surface was rubbed with pH 1 citric acid for $\frac{1}{2}$ min., 1 min., 1 $\frac{1}{2}$ min., 2 min., and 3min, respeaively in the test group and implant surface was not treated in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In titanium plasma-sprayed surfaces, round or amorphous particles were deposited irregularly. The irregularity of titanium plasma-sprayed surfaces conditioned with pH 1 citric acid was lessened and the cracks were increased relative to the application time of pH 1 citric acid. 3. Sand-blasted, large grit, acid etched surfaces showed the macro/micro double roughness. The application of pH 1 citric acid didn't change the characteristics of the sand-blasted, large grit, acid etched surfaces. In conclusion, the application of pH 1 citric acid to titanium plasma-sprayed surface is improper. And pure titanium machined surface implants and sand-blasted, large grit, acid etched surface implants can he treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

Fine Granulation Characteristics of Freeze-Dried Royal Jelly (동결건조 로얄제리의 세립가공 특성)

  • Choi, In-Hag;Lee, Gee-Dong
    • Food Science and Preservation
    • /
    • v.20 no.1
    • /
    • pp.62-68
    • /
    • 2013
  • A fine granule was prepared using freeze-dried royal jelly. For its preparation, which depended on operational parameters like its glucose-to-total sugar content ratio ($X_1$,0-100%), ethanol concentration ($X_2$,75-95%) and sprayed ethanol solution content ($X_3$,8-12%) using freeze-dried royal jelly, the response surface methodology was used to monitor the optimum conditions for the yield, the fragmentation rate with shaking, and the organoleptic properties. The maximum yield was 89.99% with a glucose-to-total sugar content ratio of 59.30%, an ethanol concentration of 88.64%, and a sprayed ethanol solution content of 11.83%. The minimum fragmentation rate by shaking was 0.82% at the glucose-to-total-sugar content ratio of 22.35%, the ethanol concentration of 77.21%, and the sprayed ethanol solution content of 10.59%. The sensory score for the overall palatability of the organoleptic properties was 7.45 at the glucose-to-total-sugar content ratio of 31.81%, the ethanol concentration of 93.96%, and the sprayed ethanol solution content of 10.51%.

Studies on the Growth Rate of Silkworm Bombyx mori (L.) (Lepidoptera: Bombycidae) Fed with Control and Silver Nanoparticles (AgNps) Treated MR2 Mulberry Leaves

  • Prabu, Ponraj Ganesh;Sabhanayakam, Selvi;Mathivanan, Veeranarayanan;Balasundaram, Dhananjayan
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.22 no.2
    • /
    • pp.39-44
    • /
    • 2011
  • To evaluate the growth rate of larval and pupal parameters of silkworm Bombyx mori fed with Silver Nanoparticles (AgNps) treated $MR_2$ mulberry leaves, the following works have been considered. The AgNp was synthesized by chemical reduction method, it was diluted by different concentrations such as 25%, 50%, 75% and 100% (without dilution). Fresh mulberry leaves (Morus alba L.) were sprayed by each concentration and were fed to silkworms, from $3^{rd}$, $4^{th}$ and $5^{th}$ instar, five feedings/day. Group $T_1$ larvae received $MR_2$ mulberry leaves sprayed with distilled water and served as control, group $T_2$, $T_3$, $T_4$ and $T_5$ larvae received 25%, 50%, 75% and 100% AgNps sprayed mulberry leaves, respectively. Silkworm larvae fed on M. alba ($MR_2$) leaves sprayed with 25% concentration of AgNps (group $T_2$) was significantly increased the larvae and cocoon length, width and weight as compared to those fed on control (group $T_1$) $MR_2$ mulberry leaves and other groups ($T_3$, $T_4$ and $T_5$). Hence, 25% AgNps dose was fixed as an effective dose. It has been observed from the present study that 25% AgNps treated (group $T_2$) leaves fed by silkworms have enhanced the larval and pupal growth and quantity of silk production than control.

An Experimental Study to Secure Electromagnetic Pulse Shielding Performance of Concrete Coated by an Arc Metal Spraying Process (아크 금속 용사 공법에 의해 코팅된 콘크리트의 전자기파 차폐 성능 확보를 위한 실험적 연구)

  • Jang, Jong-Min;Jeong, Hwa-Rang;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.519-527
    • /
    • 2021
  • In this study, an electromagnetic pulse shielding effect was obtained by applying the arc metal spraying method to the ordinary concrete. For this study, to evaluate the electrical properties in the thickness of the metal sprayed coating, 8 types of metals(Cu, CuAl, CuNi, CuZn, Al, Zn, ZnAl, AlMg) were sprayed as coatings with a thickness of 100, 200 and 500㎛. The electrical conductivity on the surface was measured with a 4-pin probe, and an electromagnetic wave shielding effect test was performed according to KS. Based on the test results, 200 ㎛ was proposed as an optimal metal coating thickness for electromagnetic pulse shielding, and it was thermally sprayed on a 300×300×100mm concrete specimen to analyze the electromagnetic wave shielding performance. However, in the area of adhesion strength, the maximum was 1.11MPa, which was found to be less than 74% of the target performance.

Temperature Distribution of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance of Tunnel (터널 내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 발생시 내부온도분포)

  • Won, Jong Pil;Choi, Seok Won;Park, Chan Gi;Park, Hae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4C
    • /
    • pp.283-290
    • /
    • 2006
  • Concrete has advantages in fire situations as it is non-combustible and has low thermal conductivity. However, concrete that is not designed against fire can experience significant explosive spalling from the build-up of pore pressures and internal tensile stresses when heated. In this study, the performance of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system was evaluated by experimentally and numerically. The fire test was performed in fire resistance(electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von $Stra{\beta}entunneln$) time heating temperature curve, so as to evaluate the temperature distribution with cover thickness of wet-mixed high strength sprayed polymer mortar for fire resistance of tunnel system. Based on experimental results and numerical analysis, the proper cover thickness of wet-mixed high strength sprayed polymer mortar determined the more than 4cm.