• 제목/요약/키워드: Spray cross section

검색결과 34건 처리시간 0.019초

Dense Spray Patternation using Optical Tomography

  • Cho, Seongho;Park, Gujeong;Yoon, Youngbin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권4호
    • /
    • pp.398-407
    • /
    • 2013
  • Optical tomography was used to measure the pattern of spray cross-section. The maximum-likelihood estimation (MLE) algorithm was used to reconstruct the spray cross-section from the measured transmission rate of the spray. A swirl-type injector was used to form an optically dense spray, and the test was carried out in a high-pressure chamber, to control the pressure condition of the test site. Before the experiment, the reliability of the MLE-based reconstruction algorithm was verified, by comparing it with a conventional filtered back projection reconstruction (FBP) method. The MLE algorithm showed superior reconstruction of the image. In the spray patternation experiment, the results of the optical tomography and optical line patternator, which uses Mie scattering signal information, were compared. While measuring the cross-section of optically dense spray, the intensity of the scattering signal had attenuated to an uncorrectable level, which led to incorrect spray pattern measurement by the optical line patternator. However, reliable results were obtained by optical tomography, under the same condition. Finally, the pattern of the optically dense spray was measured at various chamber pressures, of up to 3 MPa. As the chamber pressure increased, the hollow cone-shaped swirl spray shrank, and the attenuation coefficient value of the inner region increased.

Characteristics of Droplet Properties in the Two-Phase Spray into a Subsonic Cross Flow

  • Lee, I.C.;Cho, W.J.;Koo, J.Y.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.358-363
    • /
    • 2008
  • The spray cross-section characteristics of two-phase spray that using external-mixing nozzle injected into a subsonic cross flow were experimentally studied with various ALR ratio that is $0{\sim}59.4%$. Suction type wind tunnel was used and experiments were conducted to ambient environment. Several plain orifice nozzles with L/d of 30 and orifice diameter of 0.5 mm and orifice length 1.5 mm were tested. Free stream velocity profiles at the injection location were measured using hot wire. Spray images were captured to study collision point and column trajectory. Phase Doppler particle analyzer(PDPA) was utilized to quantitatively measuring droplet SMD, volume flux. Measuring probe of PDPA positions was moved 3-way transverse machine. SMD distributions were layered structure and peaked at the top of the spray plume and low value at bottom of the spray. Volume flux of spray was distributed to the two side region and volume flux quantity decreased when ALR ratio increased. It was found that the perpendicularly injected two-phase spray jet of external mixing into a cross flow showing that mistlike spray moved away from the test section bottom region.

  • PDF

고압 환경에서의 분무 특성 계측을 위한 광학 토모그래피 기법 연구 (Study of Optical Tomography for Measurement of Spray Characteristics at High Ambient Pressure)

  • 조성호;임지혁;최호연;윤영빈
    • 한국추진공학회지
    • /
    • 제13권4호
    • /
    • pp.36-44
    • /
    • 2009
  • 광학 선형 패터네이터 및 광학 토모그래피 기법을 사용하여 높은 주위 기체 압력 조건에서 분무단면을 측정하였다. 레이저 직선광이 분무 영역을 지나도록 하여 발생하는 Mie 산란 신호 및 직선광의 투과율을 측정하였으며, 이로부터 Beer-Lambert 법칙 및 수학적 단면 재구성 기법을 이용하여 분무 단면의 감쇠 계수 분포를 재구성하였다. 높은 주위 기체 압력 조건에서 광학적으로 밀한 분무가 발생하며, 그 결과 산란 신호의 감쇠 효과가 크게 증가한다. 따라서 미 산란 신호를 이용하는 광학 선형 패터네이터의 경우 감쇠 효과를 완화하는 데 한계를 보인다. 광학 토모그래피의 경우 분무를 통과하는 레이저광의 투과율 정보만을 이용하여 성공적으로 분무 단면을 재구성하였다.

분무패턴 분석을 이용한 가솔린 직접 분사식 인젝터의 개별 분무플럼 분무각 측정 방법에 대한 연구 (A Study on the Measurement of Individual Spray Cone Angle from Gasoline Direct Injection Injector using Spray Pattern Analysis)

  • 박정현;조한빈;박수한
    • 한국분무공학회지
    • /
    • 제25권2호
    • /
    • pp.51-59
    • /
    • 2020
  • The purpose of this study is to propose and compare methods for measuring individual spray cone angles using spray cross-section images. In direct injection gasoline engines, it was believed that the distribution of air-fuel mixture in the combustion chamber directly affected combustion performance and emission formation. However, since gasoline direct injection (GDI) injectors have a small injection angle, interference between individual spray plumes occurs. Therefore, GDI injectors have only measured the spray angle of the entire spray. To overcome these limitations, three methods of indirectly measuring the spray cone angles of individual spray plume were presented and compared by forming sheet beams using Nd:YAG laser and acquiring spray cross-section images. Each method currently has advantages and disadvantages, and research to apply the method suitable for various GDI injectors needs to be continued.

자동차 헤드램프 세척용 재순환 챔버 노즐의 내부유동이 분무장에 미치는 영향 (Effect of Internal Flow inside Recirculation Chamber Nozzle for Automative Head Lamp on Cleaning Spray)

  • 신정환;이인철;강영수;김종현;구자삼;구자예
    • 한국분무공학회지
    • /
    • 제16권2호
    • /
    • pp.90-96
    • /
    • 2011
  • Atomized liquid jets from the washing nozzle which configured with recirculation chamber for cleaning hot-zone area are accelerated and impinged on the head lamp surface. Cleaning efficiency of head lamp can be increased with injecting washing fluids into the hot-zone area. Experimental and numerical studies with various design parameters were executed to reveal the relations between internal geometry and internal flow in the washing nozzle. Spray structures were fitted with each of the head lamp surfaces and spray nozzles were optimized to the spray pattern. The recirculation chamber induces a recirculation flow and can be decreased the pressures perturbation inside the chamber. Orifice determines the mass flow rate. When the diameter of orifice is excessively large, it showed an unstable spray pattern. As a nozzle exit angle increases, density distributions are separated with two section. Also, as a protrusion length of nozzle exit increases, spray patterns are spread into a large area and density distributions showed unstable trend.

가솔린 엔진용 분사노즐의 간헐적인 분무특성 (Intermittent Spray Characteristics of the Injection Nozzle for a Gasoline Engine)

  • 김원태;오제하;강신재;노병준
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.128-136
    • /
    • 1997
  • Spray characteristics of a fuel injector have an important effect upon engine power and emission. Thus this study was investigated the spray characteristics of the intermittent injection using a gasoline fuel injector. Image processing system and PDA system were utilized for visualization of a spray behavior and measurements of a droplet size and velocity, respectively. Fuel injection duration was fixed with 3ms and injection pressure was varied such as 250kPa, 300kPa, 350kPa. for a high fuel injection pressure, spray tip arrival time was fluctuated at a vigorously disintegrated cross section. Axial velocity was linear correlated with fuel droplet size in the time interval of an injected main spray at spray downstream.

  • PDF

A Study of the Relation Between Nozzle Geometry, Internal flow and Sprays Characteristics in Diesel Fuel Injection Systems

  • Payri, Raul;Molina, S.;Salvador, F.J.;Gimeno, J.
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1222-1235
    • /
    • 2004
  • This study examines the influence of geometry on the internal flow and macroscopic behavior of the spray in Diesel nozzles. For this investigation, two bi-orifice nozzles were employed: one cylindrical and one conical. The first step is to use a non-destructive characterization method which is based on the production of silicone moulds so that the precise internal geometry of the two nozzles can be measured. At this stage the nozzles have been characterized dimensionally and therefore the internal flow can be studied using CFD calculations. The results gained from this experiment make it possible also to ascertain the critical cavitation conditions. Once the critical cavitation conditions have been identified, the macroscopic parameters of the spray can be studied in both cavitating and non-cavitating conditions using a test rig pressurized with nitrogen and with the help of a image acquisition system and image processing software. Consequently, research can be carried out to determine the influence that cavitation has on macroscopic spray behavior. From the point of view of the spray macroscopic behavior, the main conclusion of the paper is that cavitation leads to an increment of the spray cone angle. On the other hand, from the point of view of the internal flow, the hole outlet velocity increases when cavitation appears. This phenomenon can be explained by the reduction in the cross section of the liquid phase in the outlet section of the hole.

토모그래피 기법을 이용한 고압 조건에서의 스월 분사기의 분무 분포 계측 (Measurement of Spray Distribution of Swirl Injector by Tomography Method at High Pressure Condition)

  • 박구정;조성호;정재묵;김태성;윤영빈
    • 한국추진공학회지
    • /
    • 제15권5호
    • /
    • pp.66-71
    • /
    • 2011
  • 고압의 주위 압력 영역에서 토모그래피 기법을 이용하여 분무의 단면을 계측하였다. 구성된 분무 단면은 간접촬영방법을 이용한 이미지와 함께 비교되어 분무 단면의 크기를 확인하였고 토모그래피에 의해 재구성된 단면의 경계를 설정할 수 있었다. 이를 통해 고압의 주위 압력 영역에서도 토모그래피를 적용하여 분무를 구성할 수 있다는 것을 확인하였다.

Laser Raman Scattering을 이용한 가스 분무내 당량비 계측에 관한 연구 (Equivalence Ratio Measurements in Gas Spray Using Laser Raman Scattering)

  • 진성호;박경석;송재익;김경수
    • 한국분무공학회지
    • /
    • 제2권4호
    • /
    • pp.7-14
    • /
    • 1997
  • Laser Raman scattering method has been applied to measure equivalence ratio of methane/air mixture in injected spray. We used high power KrF excimer laser$(\lambda=248nm)$ and a high gain ICCD camera to capture low intensity signal. Raman shifts and Raman scattering cross -sections of $H_2,\;O_2,\;N_2,\;CO_2,\;CH_4\;and\;C_3H_8$ are measured precisely. Our results show an excellent agreement with those of other groups. Mole fraction measurement of $O_2\;and\;N_2$ from air shows that $O_2:N_2=0.206:0.794$. We used gas injector which was operated at 1 bar. Methane is used as a fuel. Spray region is $10mm\times37mm$ and this region is divided into 80 points. In Raman signals are obtained and ensemble averaged for each point. 3-d and contour plot of distribution of equuivalence ratio is presented. Our measured results show that the equivalence ratio of methane/air mixture in methane-rich region is reasonable. However, more study is necessary for methane-lean region because background noise level is almost same as Raman intensity of methane.

  • PDF