• Title/Summary/Keyword: Spray Width

Search Result 113, Processing Time 0.023 seconds

Dietary spray-dried plasma improves intestinal morphology of mated female mice under stress condition

  • Liu, Yanhong;Choe, Jeehwan;Kim, Sheena;Kim, Byeonghyeon;Campbell, Joy M.;Polo, Javier;Crenshaw, Joe D.;Pettigrew, James E.;Song, Minho
    • Journal of Animal Science and Technology
    • /
    • v.60 no.6
    • /
    • pp.10.1-10.6
    • /
    • 2018
  • Background: Stress causes inflammation that impairs intestinal barrier function. Dietary spray-dried plasma (SDP) has recognized anti-inflammatory effects and improvement of gut barrier function. Therefore, the purpose of this study was to investigate the effects of dietary SDP on intestinal morphology of mated female mice under stress condition. Results: Villus height, width, and area of small intestines were low on gestation day (GD) 3 or 4 under stress conditions, and higher later (Time, P < 0.05). Crypt depth of colon was low on GD 4 and higher later (Time, P < 0.05). Meanwhile, the SDP treatments improved (P < 0.05) intestinal morphology, indicated by increased villus height, villus width, villus area, and ratio between villus height and crypt depth of small intestines and crypt depth of colon, and by decreased crypt depth of small intestines, compared with the control diet. The SDP treatments also increased (P < 0.05) the number of goblet cells in intestines compared with the control diet. There were no differences between different levels of SDP. Conclusion: Dietary SDP improves intestinal morphology of mated female mice under stress condition.

Study on Experimental Verification of Uniform Control using Agricultural Drone (농업용 방제 드론을 이용한 균일 방제에 관한 실험적 검증)

  • Wooram Lee;Sang-Beom Lee; Jin-Teak Lim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.575-580
    • /
    • 2023
  • This study was prevent the decrease in crop output by insect pests and spraying by application uniformity. A flight level 4 m height and 4-5 m/sec. speed are difficult to maintain with a agricultural drone for aerial application, which has been affected by the methods or environmental factors, such as changes in the wind. Therefore, which can allow a controlled application width and spray rate automatically and verified experimentally using drone. The sprayed particles began to decrease from about 3.75 m on the left and right sides of the spray nozzle. According to the number of particles, the effective spraying width was observed to be about 7.5 m, and it was verified that the proposed spraying system was effective in uniform control system.

Effect of Nozzle Cap Geometry for Swirl-Type Two-Fluid Nozzle on the Spray Characteristics (선회형 이유체노즐의 노즐캡 형상에 따른 분무특성)

  • Choi, Y.J.;Kang, S.M.;Kim, D.J.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.134-142
    • /
    • 2008
  • In the case of heavy duty diesel engines, the Urea-SCR system is currently considered to reduce the NOx emission as a proved technology, and it is widely studied to get the high performance and durability. However, the nozzles to inject the urea-water solution into the exhaust pipe occur some problems, including the nozzle clogging, deposition of urea-water solution on the inner wall of the exhaust pipe, resulting in the production of urea salt. In this study, a swirl-type twin-fluid nozzle to produce more fine droplets was used as a method to solve the problems. The effect of the nozzle cap geometry, including the length to diameter ratio ($l_o/d_o$) and chamfer, on the spray characteristics were investigated experimentally. The length to diameter ratio of nozzle cap were varied from 0.25 to 1.125. The chamfer angle of the nozzle cap was constant at 90o. The mean velocity and droplet size distributions of the spray were measured using a 2-D PDA (phase Doppler analyzer) system, and the spray half-width, AMD (arithmetic mean diameter) and SMD (Sauter mean diameter) were analyzed. At result, The larger length to diameter ratio of nozzle cap were more small SMD and AMD. The effect of the chamfer did increase the radial velocity, while it did not affect the atomization effect.

  • PDF

Development of Aerial Application System Attachable to Unmanned Helicopter - Basic Spraying Characteristics for Aerial Application System - (무인헬리콥터를 이용한 항공방제시스템 개발(I) - 항공방제시스템 구축을 위한 기초 분무특성 -)

  • Kang, Tae-Gyoung;Lee, Chai-Sik;Choi, Duck-Kyu;Jun, Hyeon-Jong;Koo, Young-Mo;Kang, Tae-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.215-223
    • /
    • 2010
  • In order to develop an precision aerial pesticide application system to be attached to an unmanned helicopter which can be applied to small lots of land, this study analyzed the flowing and spraying characteristics of the spray droplets by the main rotor downwash by setting the application conditions at the flight altitude of 3 m, the diameter of main rotor of 3.1 m, the boom length of around 2.8 m, and the spraying rate of 8 L/ha. The results of this study are summarized below. Through analysis of the covering area ratio of the spray droplets by main rotor downwash by nozzle type, boom with tilt angle and height, it was found that the covering area ratio of the twin flat-fan nozzle of around 25% was more uniform than other types of nozzle, also boom with $10^{\circ}$ tilt angle and spraying height of 3 m was shown to be the appropriate conditions for aerial application of pesticides. It was found that the nozzle position to minimize the scattering loss of spray droplets due to vortex phenomenon at both ends of the main rotor was around 10 cm from the end of the main rotor. An application test for the aerial pesticide application system attached to the HUA-ACEI unmanned helicopter developed by the Rural Development Administration showed that the range of covering area ratio of the spray droplets was 10-25%, and the spraying width was approximately 7 m when over 10% of covering area ratio was considered for valid spraying.

Method of Setting Nozzle Intervals at the Finishing Scale Breaker

  • Park, Jong-Wook;Kim, Sung-Cho;Park, Jin-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.870-878
    • /
    • 2003
  • The scale is removed from the strip by high pressure hydraulic descaling at the FSB (Finishing Scale Breaker). Recently, the spray height of nozzle has a trend to be shorter for the purpose of increasing the impact pressure by the high pressure water jet. Here, the nozzle intervals should be decided after considering the impact pressure and the temperature distribution on the strip. In other words, the minimum of impact pressure at the overlap of spray influences the surface grade of the strip due to scale and the overlap distance of the spray affects the temperature variation in the direction of the width of strip. In the present study, the impact pressure of the high pressure water jet is measured by the hydraulic descaling system and calculated with regard to the lead angle of 15$^{\circ}$ and the offset angle of 15$^{\circ}$, and then the temperature distribution and the temperature variation are calculated at the overlap distances of 0 mm, 10 mm, 20 mm, and 30 mm, respectively. The method of setting nozzle intervals is shown by utilizing these results.

Development Behavior of Vaporizing Sprays from a High-Pressure Swirl Injector Using Exciplex Fluorescence Method

  • Choi, Dong-Seok;Kim, Duck-Jool;Hwang, Soon-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1143-1150
    • /
    • 2000
  • The effects of ambient conditions on vaporizing sprays from a high-pressure swirl injector were investigated by an exciplex fluorescence method. Dopants used were 2% fluorobenzene and 9% DEMA (diethyl-methyl-amine) in 89% solution of hexane by volume. In order to examine the behavior of liquid and vapor phases inside of vaporizing sprays, ambient temperatures and pressures similar to engine atmospheres were set. It was found that the ambient pressure had a significant effect on the axial growth of spray, while ambient temperature had a great influence on the radial growth. The spatial distribution of vapor phase at temperatures above 473K became wider than that of liquid phase after half of injection duration. From the analysis of the area ratio for each phase, the middle part (region II) in the divided region was the region which liquid and vapor phases intersect. For liquid phase, fluorescence-intensity ratio was greatly changed at lms after the start of injection. However, the ratio of vapor phase was nearly uniform in each divided region throughout the injection.

  • PDF

EXPERIMENTAL STUDY ON THE STRATIFIED COMBUSTION CHARACTERISTICS ACCORDING TO COMPRESSION RATIO AND INTAKE TEMPERATURE IN A DIG ENGINE

  • Lee, C.H.;Lee, K.H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.6
    • /
    • pp.675-680
    • /
    • 2006
  • In the direct injected gasoline engine, atomized spray is desired to achieve efficient mixture formation needed to good engine performance because the injection process leaves little time for the evaporation of fuels. Therefore, substantial understanding of global spray structure and quantitative characteristics of spray are decisive technology to optimize combustion system of a GDI engine. The combustion and emission characteristics of gasoline-fueled stratified-charge compression ignition(SCCI) engine according to intake temperature and compression ratio was examined. The fuel was injected directly to the cylinder under the high temperature condition resulting from heating the intake port. With this injection strategy, the SCCI combustion region was expanded dramatically without any increase in NOx emissions, which were seen in the case of compression stroke injection. Injection timing during the intake temperature was found to be an important parameter that affects the SCCI region width. The mixture stratification and the fuel reformation can be utilized to reduce the required intake temperature for suitable SCCI combustion under each set of engine speed and compression ratio conditions.

Microscopic Spray Characteristics in the Effervescent Atomizer with Two Aerator Tubes

  • Kim, Hyung-Gon;Toshiaki Yano;Song, Kyu-Keun;Torii Shuichi
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1661-1667
    • /
    • 2004
  • An experimental study is performed on atomization characteristics and stable operating conditions for the injection of high viscous waste vegetable oil using an effervescent atomizer with 2 aerator tubes. Consideration is given to the effects of ALR and liquid viscosity on the velocity and mean diameter of the injected droplet. It is found that (i) as ALR increases, the axial velocity of the droplet is increased, while half-velocity width and SMD are decreased regardless of the change in liquid viscosities, (ii) the rate of fine drop distribution occupied in the total spray field is increased with an increase in ALR, and (iii) the effect of viscosity on the atomization characteristics is minor. Consequently, it is expected that the effervescent atomizer will exhibit an excellent atomization performance at the high ALR condition, regardless of liquid viscosities.

Structure and Electrical Properties of $Ru_{1-x}Ir_xO_2$ Films Deposited by a Spray Phrolysis (분무열분해법으로 성장한 $Ru_{1-x}Ir_xO_2$ 박막의 구조와 전기적 특성)

  • 서동주;이관교;이재연
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.1
    • /
    • pp.67-72
    • /
    • 1996
  • $RU_{1-x}Ir_xO_2$ films were deposited on the quartz substrate by a spray pyrolysis method. The x-ray diffraction patterns showed that the structure of the $RU_{1-x}Ir_xO_2$ film was tetragonal and the lattice constant $a_o$ and $c_o$ were increased from 4.495 A to 4.058 A and from 3.092A to 3.156 A, respectively as the Ir composition varied from 0.0 to 1.0. The $RU_{1-x}Ir_xO_2$ film was metallic and the resistivity of the samples was increased from $7{\times}10^{-5}{\Omega}\textrm{cm}$ to $48{\times}10^{-5}{\Omega}\textrm{cm}$ with increasing the Ir x. The surface of the sample was slightly roughed, the grain size and the grain boundary width were increased as the Ir composition varied from 0.0 to 1.0.

  • PDF

Effect of Pesticide on Biological Traits of an Orb-web Spider, Trichonephila clavata Koch (Araneae: Araneidae) in Pinus densiflora Forests in Mt. Geumjeong, Korea (살충제 살포가 금정산 소나무림 내 무당거미(거미목 : 왕거미과)의 생물적 형질에 미치는 영향)

  • Jung, Jong-Kook;Kim, Junheon;Kim, Dongsoo;Jung, Chuleui
    • Korean journal of applied entomology
    • /
    • v.59 no.3
    • /
    • pp.209-215
    • /
    • 2020
  • Debates over the ecological and public health impacts of aerial pesticide sprays are increasing. This is particularly true for controlling Monochamus beetles, which are vector insects of pinewood nematodes. In 2017, adult female orb-web spiders, Trichonephila clavata, were sampled from pine forests in Yangsan-si, Gyeongsangnam-do, Korea, where the aerial pesticide spray, fenitrothion or thiacloprid, was used for several decades. The biological traits of the spiders (body weight, body length, carapace width, and total hind leg length) were compared among treatment sites (no-spray, sprayed three times, and sprayed five times), and differences were observed. The body length, carapace width, and total hind leg length of the spiders in the sprayed areas were significantly shorter than in the no-spray area, but there were no differences between the area sprayed three or five times. These results indicate that repeated exposures to an aerial pesticide spray can alter morphological parameters, which influences population-level fitness. Future studies should monitor the spider long-term responses to pesticides (a direct effect) and prey availability (an indirect effect).