• Title/Summary/Keyword: Spray Coating

Search Result 754, Processing Time 0.027 seconds

Proposals to Revise the Occupational Exposure Limits for Aluminum in Korea (국내 크롬 및 그 화합물의 노출실태 및 노출기준 개정 제안)

  • Seung Won Kim;Young Gyu Phee;Yong-Joon Baek;Taejin Chung;Jeong-Hee Han
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.166-178
    • /
    • 2024
  • Objectives: The 12 occupational exposure limits(OELs) for chromium and its compounds in Korea were set by applying the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs). However, this is significantly different from the TLVs after the existing TLVs were integrated and withdrawn in 2018, so it is necessary to review the revision. Methods: Various documents related to chromium OELs were reviewed, including the ACGIH TLV Documentations for chromium and its compounds. A field survey was conducted targeting workplaces handling chromium and its compounds. Based on this, a revised OELs were proposed and a socio-economic evaluation was conducted. Results: The OELs for chromium compounds in Korea was first enacted in 2002, and in 2007, the OELs for chromium (hexavalent) compounds (insoluble) was lowered from 0.05 mg/m3 to 0.01 mg/m3. In 2008, the OELs for strontium chromate was newly established as 0.0005 mg/m3, and in 2018, the OELs for calcium chromate was newly established as 0.001 mg/m3. Total chromium and hexavalent chromium were measured for each of 6 samples at 2 welding sites, 4 plating sites, and 2 spray coating sites. When omparing the average of the results measured by ICP, a total chromium analysis method, and the analysis results by IC, a hexavalent chromium analysis method, only workplace 4 was the same, and total chromium was evaluated more, and total chromium was evaluated at 0.0004 to 0.0027 mg/m3. And hexavalent chromium was evaluated as non-detection ~ 0.0014 mg/m3. Amendment ①: The exposure standard for hexavalent chromium is not divided into water soluble, insoluble, chromium ore processing, and other hexavalent chromium compounds, and is integrated into 0.01 mg/m3, which is the level of chromium (hexavalent) compound (insoluble)., OELs for chromium (metal) and chromium (trivalent) compounds are integrated into chromium (trivalent) compounds, and the exposure level is maintained. Amendment ②: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.005 mg/m3, which is the OELs of OSHA, and there is a grace period of 4 years. Amendment ③: As in the amendment ①, the OELs are integrated, but the level is lowered to 0.0002 mg/m3, which is the exposure standard of ACGIH, and there is a grace period of 5 years. Conclusions: Amendment ①: The change in the OELs is insignificant, so the cost required is small, and the benefit/cost ratio is greater than 1, so there is no problem in applying the amendment. Amendment ②: In all scenarios except chromium 6(insoluble), the benefit/cost ratio is greater than 1, so it is thought that there will be no major problem in applying the amendment. Amendment ③: Since the benefit/cost ratio is less than 1 in all scenarios, it is thought that the total social benefit that can be obtained when applying the amendment is not large.

Effects of Tree-spray of Calcium Agent, Coating Agent, GA4+7 + BA and Paper Bagging on Russet Prevention and Quality of 'Gamhong' Apple Fruits (칼슘제, 피막제, GA4+7 + BA의 수체살포 및 봉지씌우기에 의한 '감홍' 사과의 동녹 방지와 과실품질)

  • Moon, Young-Ji;Nam, Ki-Woong;Kang, In-Kyu;Moon, Byung-Woo
    • Horticultural Science & Technology
    • /
    • v.34 no.4
    • /
    • pp.528-536
    • /
    • 2016
  • This study was conducted to examine the effect of 0.4% of $CaCl_2$, $2H_2O$, $1mg{\cdot}L^{-1}$ of Calmodulin (CaM)-SH, 250-folds of coating agent (WE-36), 1,000-folds of $GA_{4+7}+BA$ and 3 types of paper bagging treatments on russet incidence and fruit quality attributes of 'Gamhong' apple. The pattern of russet occurrence was slightly different for 4 years (from 2012 to 2015) in 'Gamhong' apple. The russet occurrence was lowest in $GA_{4+7}+BA$ treatment at 20 days after full bloom (DAFB), compared with other treatments. The $GA_{4+7}+BA$ treatment increased fruit weight at 20 DAFB, while the other fruit quality attributes were not influenced. The russet occurrence was lower not only in a single bag application than in untreated ones but also in yellow bagging and discolored bagging applications than in a white bagging application. The russet occurrence in a bagging application was lower at 20 DAFB than at 30 and 40 DAFB, while fruit quality attributes were not affected by bagging applications. The russet incidence was lower in $GA_{4+7}+BA$ twice treatments at 20 and 30 DAFB, and calcium coated bag at 30 DAFB after $GA_{4+7}+BA$ treatment at 20 DAFB than in untreated fruit. The rate of russet incidence was lowest at equator region in $GA_{4+7}+BA$ treatment, compared with the other fruit regions. Overall, the results suggest that one and/or two applications of $GA_{4+7}+BA$ (1,000-folds) treatment at 20 DAFB should reduce the risk of russet incidence in 'Gamhong' fruit.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

MICROTENSILE BONDING OF RESIN FIBER REINFORCED POST TO RADICULAR DENTIN USING RESIN CEMENT (레진 시멘트를 이용한 레진 파이버 강화 레진포스트의 치근 상아질에 대한 미세인장결합강도)

  • Kim, Jin-Woo;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.80-88
    • /
    • 2003
  • Object The purpose of this study were to evaluate the microtensile bond strength of resin fiber reinforced post to radicular dentin using resin cement according to various dentin surface treatment and to observe the inter face between post and root dentin under SEM Material and Method A total 16 extracted human single rooted teeth were used. A lingual access was made using a #245 carbide bur in a high-speed handpiece with copious air water spray. The post space was mechanically enlarged using H-file(up to #60) and Gates Glidden bures(#3). This was followed by refining of the canal space using the calbrating drill set provided in ER Dentinpost(GEBR, BRASSELER GmbH&Co. KG). The 16 teeth were randomly distributed into 4 group of 4 teeth. Group 1 teeth had their post space prepared using 10% phosphoric acid as root canal surface treatment agent during 20s. The canal was then rinsed with saline and dried with paper point. Group 2 teeth had their post space prepared using 3% NaOCl as root canal surface treatment agent during 30min. The canal was then rinsed with saline and dried with paper point. Group 3 teeth had their post space prepared using 17% EDTA as root canal surface treatment agent during 1min. The canal was then rinsed with saline and dried with paper point. Group 4 teeth had their post space prepared using 17% EDTA as root canal surface treatment agent during 1min. After rinsing with saline, the canal was rinced 10m1 of 3% NaOCl for 30min. After drying with paper point, the post(ER Dentinpost, GEBR, BRASSELER GmbH&Co. KG) was placed in the treated canals using resin cement. Once the canal was filled with resin cement(Super bond C&B sunmedical co. Ltd.), a lentulo was inserted to the depth of the canal to ensure proper coating of the root canal wall. After 24 hours, acrylic resin blocks($10{\cdot}10{\cdot}50mm$) were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strengths for each stick was measured with Microtensile Tester. Failure pattern of the specimen at the interface between post and dentin were observed under SEM. Results 1. Tensile bond strengths(meen{\pm}SD$) ) were expressed with ascending order as follows group 4, $12.52{\pm}6.60$ ; group 1, $7.63{\pm}5.83$ ; group 2, $4.13{\pm}2.31$ ; group 3, $3.31{\pm}1.44$. 2. Tensile bond strengths of Group 4 treated with 17% EDTA +3%NaOCl were significant higher than those of group 1, 2 and 3 (p<0.05). 3. Tensile bond strengths of Group 1 treated with 10% phosphoric acid were significant higher than those of group 2 (p<0.05). Tensile bond strengths of Group 4 treated with 17% EDTA +3% NaOCl was significant higher than those of other groups.