• Title/Summary/Keyword: Spotter

Search Result 15, Processing Time 0.02 seconds

p-type Zn Diffusion using by Solid State Method of $GaAs_{0.60}P_{0.40}$ and the Properties of Electroluminescence (고상 확산 법에 의한 P-type Zn 확산과 $GaAs_{0.60}P_{0.40}$의 전계발광 특성)

  • Pyo, Jin-Goo;Lim, Keun-Young;So, Byung-Moon;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.481-485
    • /
    • 2003
  • To diffuse Zn at solid-state, the $SiO_2/ZnO/SiO_2$ wafers was made by PECVD and RF Spotter. Thicknesses of bottom $SiO_2$ and cap $SiO_2$ was about $500{\AA}$ and about $3500{\AA}$. First test was Diffusion temperatures were $760^{\circ}C$, $780^{\circ}C$, and $800^{\circ}C$, and diffusion times were 1, 2, 3, 4, 5, and 6 hr and 2nd test was Diffusion temperatures were $760^{\circ}C$, $720^{\circ}C$, and $680^{\circ}C$, and diffusion times were 1, 2, 3, 4, 5, and 6 hr. LED chips were fabricated by the diffused wafers at Fab. The peak wavelength of all chips showed about $625{\sim}650\;nm$ and red color Main reason for Iv change was by diffusion temperature not diffusion time. The lower temperature was the higher Iv. We thick that these properties is because of the very high diffusion temperature.

  • PDF

A Automated Method for Training Keyword Spotter based on Speech Synthesis (키워드 음성인식을 위한 음성합성 기반 자동 학습 기법)

  • Lim, Jaebong;Lee, Jongsoo;Cho, Yonghun;Baek, Yunju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.05a
    • /
    • pp.494-496
    • /
    • 2021
  • 최근 경량 딥러닝 기반 키워드 음성인식은 가전, 완구, 키오스크 등 다양한 응용에 음성 인터페이스를 쉽게 적용할 수 있는 기술로서 주목받고 있다. 키워드 음성인식은 일부 키워드만 인식 가능한 음성인식 기술로서 저성능 디바이스에서 활용 가능한 장점이 있다. 그러나 응용에 따라 필요한 키워드에 대하여 다시 음성데이터를 수집해야하고 이를 학습하여 모델을 새로 준비해야하는 단점이 있다. 따라서 본 연구에서는 음성데이터 수집 없이 음성합성을 통해 생성한 음성으로만 키워드 음성인식 모델을 학습하는 음성합성 기반 자동 학습 기법을 제안하였다. 생성한 음성데이터를 활용하고자하는 시도가 활발히 이루어지고 있으나, 기존 연구에서는 정확도를 유지하기 위하여 수집한 실제 음성데이터가 필요한 한계가 있다. 제안한 자동 학습 기법은 생성한 음성데이터에 대해 복합 데이터 증대 기법을 적용하여 실제 음성데이터 없이 키워드 음성인식의 정확도를 높였다. 제안한 기법에 대하여 상용 음성합성 서비스를 기반으로 수집한 한국어 키워드 데이터세트를 활용하여 성능평가를 진행하였다. 20개 한국어 키워드에 대해 실험한 결과, 제안한 기법을 적용하여 학습시킨 키워드 음성인식 모델의 정확도는 86.44%임을 확인하였다.

Implementation of User Interface for DNA Micro Array Printing Technology (DNA 마이크로어레이 프린팅을 위한 사용자 인터페이스 적용기술)

  • Park, Jae-Sam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1875-1882
    • /
    • 2013
  • Micro-array technology contributes numerous achievements such as ordering of gene network and integration of genomic. This technology is well established as means for investigating patterns of gene expression. DNA micro-arrays utilize Affymetric chips where a large quantity of DNA sequences may be synthesized. There are two general type of conventional DNA array spotter: contact and piezoelectric. The contact technology used spotting pin technology to make contact with the glass slide surface. This may caused damage or scratches to the surface matrix where protein will be contaminated and may not bind specifically. Piezoelectric technology available at this present time on the other hand requires the analyzer to print the result that can only be done within the laboratory despite of mass production. Therefore, in this paper, high-throughput technology is developed for providing greater consistency in feature spot without touching the glass slide surface.

Effects of Depression and Anxiety Symptoms on Specific Cognitive Function by Evaluating Healthy Subjects (정상인을 통해 알아본 우울 증상과 불안 증상이 특정 인지 기능에 미치는 영향)

  • Kim, Kyuho;Nam, Yoon-Young;Han, Jiyeon;Yu, Rina;Ryu, Vin
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.29 no.1
    • /
    • pp.42-48
    • /
    • 2021
  • Objectives : Based on the fact that cognitive functions decline known as comorbid symptoms of depression can precede depression, this study seeks to observe the effects of depressive symptoms and anxiety symptoms on cognitive function in healthy subjects. Methods : To recruit 50 general populations to evaluate cognitive and clinical symptoms and to find out the effects of clinical symptoms on cognitive functions, Pearson correlation and multivariate regression were conducted. Correlation analysis of subdomain cognitive function was conducted for reliability analysis. Results : Trail making test-B that evaluates the execution function correlates with depressive symptoms (r=0.300, p=0.03) and age (r=0.323, p=0.02). Depressive symptoms (β=0.304, p=0.03) and age (β=0.335, p=0.01) were significantly related to Trail making test -B (Adjusted R2=0.148). Subjective cognitive tests correlates with anxiety symptoms (r=0.434, p=0.002). In the correlation between cognitive functional items, Subjective cognitive tests was found to be correlated with other test except Spotter. Conclusions : In this study, depressive symptoms contribute independently to executive functions in addition to demographic characteristics such as age and duration of education. Given that cognitive decline is a common long-term clinical outcome in depression, we expect active early intervention and evaluation of cognitive function to be helpful.

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF