• Title/Summary/Keyword: Splitting tensile test

Search Result 117, Processing Time 0.023 seconds

Fracture Behavior of Concrete Beam Subjected to Dynamic Loading (동적하중을 받는 콘크리트보의 파괴거동)

  • Kang, Sung-Hoo;Kim, Woo;Park, Sun-Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.257-262
    • /
    • 1995
  • In this study, after concrete cylinders were made on the condition of varying water-to -cement ratio, and cured 80 days compressive strength and splitting tensile strength were performed and moduls of elasticy is obtained. The fracture energy was obtained by acting three point bending on the 80cm in length. This test involved static loading test and dynamic loading test. In this work, the new interrelation of the material constants was obtained clearly and the property of the mixture was inspected, including the relation between the fracture energy and all kind of the material constants.

  • PDF

A Study on the Damage Estimation of Uni-directionally Oriented Carbon Fiber Reinforced Plastics using Acoustic Emission (음향방출을 이용한 일방향 탄소섬유강화 플라스틱의 손상평가에 관한 연구)

  • Rhee Zhang-Kyu;Park Sung-Oan;Kim Bong-Gag;Woo Chang-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.1
    • /
    • pp.30-36
    • /
    • 2005
  • This study is to investigate a damage estimation of single edge notched tensile specimens as a function of acoustic emission(AE) according to the uni-directionally oriented carbon fiber/epoxy composites, CFRP In fiber reinforced composite materials, AE signals due to several types of failure mechanisms are typically observed. These are due to fiber breakage, fiber pull-out matrix cracking, delamination, and splitting or fiber bundle breaking. And these are usually discriminated on the basis of amplitude distribution, event counts, and energy related parameters. In this case, AE signals were analyzed and classified 3 regions by AE event counts, energy and amplitude for corresponding applied load. Bath-tub curve shows 3 distinct periods during the lifetime of a single-edge-notch(SEN) specimen. The characterization of AE generated from CFRP during SEN tensile test is becoming an useful tool f3r the prediction of damage failure or/and failure mode analysis.

Fresh and hardened properties of expansive concrete utilizing waste aluminum lathe

  • Yasin Onuralp Ozkilic;Ozer Zeybek;Ali Ihsan Celik;Essam Althaqafi;Md Azree Othuman Mydin;Anmar Dulaimi;Memduh Karalar;P. Jagadesh
    • Steel and Composite Structures
    • /
    • v.50 no.5
    • /
    • pp.595-608
    • /
    • 2024
  • In this study, aluminum lathe waste was used by replacing aggregates in certain proportions in order to obtain expansive concrete using recycled materials. For this reason, five different aluminum wastes of 1%, 2%, 3%, 4% and 5% were selected and also reference without aluminum waste was produced. Based on the mechanical tests conducted, which included slump, compression, splitting tensile, and flexural tests, it was evident that the workability of the material declined dramatically once the volume ratio of aluminum exceeded 2%. As determined by the compressive strength test (CST), the CS of concrete (1% aluminum lathe wastes replaced with aggregate) was 11% reducer than that of reference concrete. It was noted that the reference concrete's CS values, which did not include aluminum waste, were greater than those of the concrete that contained 5% aluminum. When comparing for splitting tensile strength (STS), it was observed that the results of STS generally follow the parallel inclination as the CS. The reduction in these strengths when 1% aluminum is utilized is less than 10%. These ratios modified 18% when flexural strength (FS) is considered. Therefore, 1% of aluminum waste is recommended to obtain expansive concrete with recycled materials considering minimum loss of strength. Moreover, Scanning Electron Microscope (SEM) analysis was performed and the results also confirm that there was expansion in the aluminum added concrete. The presence of pores throughout the concrete leads to the formation of gaps, resulting in its expansion. Additionally, for practical applications, basic equations were developed to forecast the CS, STS, and FS of the concrete with aluminum lathe waste using the data already available in the literature and the findings of the current study. In conclusion, this study establishes that aluminum lathe wastes are suitable, readily available in significant quantities, locally sourced eco-materials, cost-effective, and might be selected for construction using concrete, striking a balance among financially and ecological considerations.

Size Effect of Concrete Structures without Initial Cracks (초기균열이 없는 콘크리트 구조물의 크기에 따른 응력감소효과에 관한 연구)

  • Kim, Jin Keun;Park, Hong Kyee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.29-36
    • /
    • 1987
  • In most of the structural members with initial cracks, the strength tends to decrease as the member size increases. This phenomenon is known as size effect. Among the structural materials of glass, metal or concrete, etc., concrete represents the size effect even without initial crack. According to the previous size effect law, the concrete member of very large size can resist little stress. Actually, however, even the large size member can resist some stress if there is no initial notch. This means that the fracture mechanism of very small or very large size member follows strength criterion, but the medium size member follows non-linear fracture mechanics (NLFM). In this study, the empirical models which are derived based on nonlinear fracture mechanics are proposed according to the regression analysis with the existing test data of large size specimens for uni-axial compression test, splitting tensile test and shear test of reinforced concrete beams.

  • PDF

Properties of Concrete Mixed with Waste Incinerated Bottom Ash (쓰레기 소각재를 혼입한 콘크리트의 재료특성 및 강도특성)

  • 어석홍;홍기호;최덕진;김희성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.217-222
    • /
    • 2002
  • The purposes of this study are to investigate the material characteristics and strength properties of concrete mixed with waste incinerated bottom ash(BA), and to evaluate the leaching of environmentally harmful heavy metals from the bottom ash itself and from hardened concrete mixed with bottom ash. For this purpose, two reference mixes with W/C ratios of 0.45 and 0.55 were used, and the replacement proportion of BA was varied with the ratios of 0%, 30%, 50%, 70%, and 100% by volume of fine aggregate in the reference mixes. The variation of compressive and splitting tensile strength, workability and unit weight of concrete were considered. Test results showed that the strengths, workability and unit weight decreased with increase in proportion of BA replaced. Leaching test results showed that there would be no environmentally harmful problem from using BA as the substitutes of fine aggregates in concrete.

  • PDF

Mechanical and Durability Performance of Roller-Compacted Concrete with Fly Ash for Dam Applications

  • Park, Chan-Gi;Yoon, Jong-Whan;Kim, Wan-Young;Won, Jong-Pil
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.57-61
    • /
    • 2007
  • This study investigated the mechanical and durability performance of roller-compacted concrete (RCC) with fly ash for dam applications. A test program studied the effects on the properties of fresh and hardened RCC with fly ash replacement ratio, as well as the long-term durability of the resulting mixture. Fly ash replaced 20, 30, 40, and 50% by mass of the cement. Laboratory tests of the compressive strength, splitting tensile strength, shear strength, chloride ion permeability, abrasion, and drying shrinkage were conducted. The test results demonstrated that 30% fly ash replacement is an optimum level, and that this mixture has excellent mechanical and durability properties.

Shear Performance of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.661-671
    • /
    • 2015
  • To evaluate the shear performance of the textile glass fiber and the sheet glass fiber reinforced glulam bolted connections, a tension type shear test was conducted. The average yield shear strength of the bolted connection of reinforced glulam was increased by 12% ~ 31% compared to the non-reinforced glulam. It was confirmed that the shear performance of 5D end distance of the glass fiber reinforced glulam connection corresponds to that of 7D of the non-reinforced glulam connection proposed in building design requirements in various countries. Compared to the non-reinforced glulam, the average shear strength of textile glass fiber reinforced glulam was markedly increased. The non-reinforced glulam and the GFRP reinforced glulam underwent a momentary splitting fracture. However, the failure mode of textile glass fiber reinforced glulam showed a good ductility.

Variation of Bilinear Stress-Crack Opening Relation for Tensile Cracking of Concrete at Early Ages (초기재령에서 콘크리트 인장균열에 대한 쌍선형 응력-균열 개구 관계의 변화)

  • Kwon, Seung-Hee;Choi, Kang;Lee, Yun;Park, Hong-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.427-435
    • /
    • 2010
  • One of the most vulnerable properties in concrete is tensile cracking, which usually happens at early ages due to hydration heat and shrinkage. In order to accurately predict the early age cracking, it needs to find out how stress-crack opening relation is varying over time. In this study, inverse analyses were performed with the existing experimental data for wedge-splitting tests, and the parameters of the softening curve for the stress-crack opening relation were determined from the best fits of the measured load-CMOD curves. Based on the optimized softening curve, variation of fracture energy over time was first examined, and a model for the stress-crack opening relation at early ages was suggested considering the found feature of the fracture energy. The model was verified by comparisons of the peak loads, CMODs at peak loads, and fracture energies obtained from the experiments and the inverse analysis.

Thermal Characteristics of Cement Concrete Mixed with Wasted Vinyl Aggregates (폐비닐 골재가 혼합된 시멘트 콘크리트의 열 특성)

  • Yeom, Woo Seong;An, Gi Hong;Liu, Ju Ho;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.79-86
    • /
    • 2014
  • PURPOSES : In this study, wasted vinyl aggregate, which possesses better thermal properties than natural aggregate, was used in cement concrete mixture to develop more economical concrete with thermal insulation and freeze prevention effects. METHODS : Slump and air content of the fresh concrete, which substituted its 0%, 5%, and 10% of coarse aggregate with wasted vinyl aggregate, were measured. Compressive strength, Poisson's ratio, elastic modulus, and splitting tensile strength of hardened concrete were measured by laboratory tests. Thermal properties of concrete such as coefficient of thermal expansion, thermal conductivity, and specific heat were also measured according to replacement ratio of wasted vinyl aggregate. Finally, the thermal insulation and freeze prevention effectiveness of the concrete mixed with wasted vinyl aggregate was confirmed through finite element analysis of road pavement crossing above concrete box culvert made from wasted vinyl aggregate. RESULTS : Even though the physical properties of wasted-vinyl-aggregate concrete such as compressive strength, Poisson°Øs ratio, elastic modulus, and splitting tensile strength were inferior to those of ordinary concrete, they met requirements for structural concrete. The thermal properties of concrete were improved by wasted vinyl aggregate because it decreased thermal conductivity and increased specific heat of the concrete. According to the result of finite element analysis, temperature variation in pavement subgrade was mitigated by box culvert made from wasted-vinyl-aggregate concrete. CONCLUSIONS : Through the laboratory test and finite element analysis of this study, it was concluded that the concrete structures made from wasted vinyl aggregate showed thermal insulation and freeze prevention effects.

Experimental Study on the Bond Properties between GFRP Reinforcements and Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트와 GFRP 보강근의 부착특성에 관한 실험적 연구)

  • Choi, Yun-Cheul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.573-581
    • /
    • 2013
  • In this paper, an experimental investigation of bond properties between steel fiber reinforced concrete and glass fiber reinforced polymer reinforcements was performed. The experimental variables were diameter of reinforcements, volume fraction of steel fiber, cover thickness and compressive strength of concrete. Bond failure mainly occurred with splitting of concrete cover. Main factor for splitting of concrete is tension force occurred by the displacement difference between reinforcements and concrete. Therefore, in order to prevent the bond failure between reinforcements and concrete, capacity of tensile strength of concrete cover should be upgraded. As a results of test, volume fraction of steel fiber significantly increases the bond strength. Cover thickness changes the failure mode. Diameter of reinforcements also changes the failure mode. Generally, diameter of reinforcement also affects the bond properties but this effect is not significant as volume fraction of fiber. Increase of compressive strength increases the bond strength between concrete and reinforcement because compressive strength of concrete directly affects the tensile strength of concrete.