• Title/Summary/Keyword: Split angle

Search Result 148, Processing Time 0.029 seconds

Development of a Split Wheel-Mounted Brake Disc for a High Speed Train (고속 열차용 분할형 차륜디스크 개발)

  • Cho, Dong-Hyun;Kang, Seong-Woong;Cho, Yeon-Jae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.583-589
    • /
    • 2010
  • This paper describes the design process and the test of split wheel-mounted brake discs for high speed train with maximum speed 180km/h. A disc set composed 2 disc rings and individual rings are partitioned into 3 pieces with the same circumferential angle. Because partitioned disc rigs are exposed to severe centrifugal force as the vehicle speed increase, finite element analyses used in the design process to ensure mechanical safety. A prototype was verified its mechanical safety through the spin test up to 250km/h. 2 prototypes for 1 wheelset are mounted to Korean Tilting Train(TTX) and have been running over 15,000km

  • PDF

A Study of Turbulence Generation Characteristics of Large Scale Vortex Flow Mixing Vane of Nuclear Fuel Rod Bundle (핵연료집합체에서의 대형이차와류 혼합날개의 난류생성 특성에 관한 연구)

  • An, J.S.;Choi, Y.D.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1819-1824
    • /
    • 2004
  • The common method to improve heat transfer in Nuclear fuel rod bundle is install a mixing vane in space grid. The previous split mixing vane is guides cooling water to swirl flow in sub-channel of fuel assembly. But, this swirl flow decade rapidly after mixing vane and the effect of enhancing the heat transfer vanish behind this short region. The large scale secondary vortex flow was generated by rearranging the inclined angle direction of mixing vanes to the coordinated directions. This LSVF mixing vanes generate the most strong secondary flow vortices which maintain about 35 $D_H$ after the spacer grid and the streamwise vorticity in subchannel with LSVF mixing vane sustain two times more than that in subchannel with split mixing vane. The turbulent kinetic energy and the Reynolds stresses generated by the mixing vanes have nearly same scales but maintain twice more than previous type.

  • PDF

Development of ABS(Anti-Lock Brake System) Real-Time Simulator (ABS(Anti-Lock Brake System)의 실시간 시뮬레이터 개발)

  • 김중배
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.229-241
    • /
    • 1999
  • The paper describes the development of the ABS(Anti-Lock Bracke Sytem) real-time simulator which is composed of the real hydraulic modulator, the brake system, and the control software. This useful too supports the development enviornment of the ABS in great flexible mamer. It offers an efficient and cost-effective method of ABS development which includes the various realistic road conditons, the vehicle characteristics , and the brake characteristics. The performance of the ABS is compared with the normal braking results. Thepresented experimental results are braking on the high friction road, thetransient friction road(high to low , low to high), the split friction road, and the high friction road with steer angle. The paper shows the effectiveness and the safety of the ABS compared with the normal brake system , and the powerful and conventient tool in developing the ABS.

  • PDF

THE CORRECTION OF CLASS III MANDIBULAR ASYMMETRY USING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY AND LATERAL ANGLE REDUCTION (외측 하악각 골절제술을 동반한 시상분할골절단술을 통한 골격성 3급 하악골 비대칭 환자의 치료)

  • Kang, Hee-Jea;Song, In-Woo;Kang, Yung-Ki;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.132-140
    • /
    • 2010
  • Purpose: The aim of this study is to identify the usefulness of unilateral mandibular angle ostectomy, so-called "Lateral Angle Reduction", in asymmetric prognathism patients by the assessment of postoperative stability and esthetic results Patients and methods: For the retrospective study, 10 skeletal class III mandibular asymmetry patients who were performed SSRO and unilateral mandibular angle ostectomy, Lateral Angle Reduction, was selected. Lateral and posterioanterior cephalogram was taken before surgery (T0), 1day after surgery (T1) and 6month after surgery (T2). To know the esthetic results the facial width and lateral facial contour were examined on posterioanterior cephalogram and to know the postoperative stability B point and Incisor inferius was examined on lateral cephalogram. Statistical analysis was performed. Results: From T0 to T1, Intergonial width was significantly decreased, dominantly at shortened side but no significant changes at lengthened side. Those were well-maintained during 6 months. Lateral facial angle and Ramus angle was significantly decreased on only shortened side from T0 to T1. As a result, after surgery, there were no significant differences in all measurements between shortened side and lengthened side. Ramus deviation angle in shortened side and ramus angle in lengthened side which reflect the angulation of ramus on frontal plane didn't show significant changes after surgery and during postsurgical periods. Lower dental midline showed no statistical changes during postsurgical period. The relapse rate on B-point was 11.92%. Conclusion: Unilateral "Lateral angle reduction" in the asymmetric mandible is valuable to obtain the narrow lower face and symmetric facial contour with a good stability.

CLINICAL ANALYSIS OF GONIAL ANGLE CHANGE AFTER ORTHOGNATHIC SUGERY IN PATIENTS WITH THE MANDIBULAR PROGNATHISM (하악전돌증환자의 악교정수술후 하악각변화에 관한 임상적 분석)

  • Kwon, Yeong-Ho;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.2
    • /
    • pp.206-216
    • /
    • 2000
  • Predictional study for lateral change between pre- and post-orthognathic surgery has been emphasized mainly on anterior area of lateral profile; upper lip, lower lip and chin et al. So interest for lateral profile change has been less in posterior area of lateral profile and literature analyzing gonial angle change is rare. The purpose of this study is to make prediction for gonial angle change possible and to offer somewhat treatment guidance for gonial angle to be improved by investigating overall gonial angle change between pre- and post-orthognathic surgery and inquiring into factors influencing on pattern of genial angle change. For this study 35 patients were selected retrospectively. Lateral cephalometric radiographs were taken in just pre-op time, pod 1 day, pod 1 year. They were analyzed and genial angles were measured. The results were as follows : 1. Gonial angle at pod 1 day was decreased about $9.3^{\circ}$ than pre-op and gonial angle at pod 1 year was increased about $4.0^{\circ}$ than pod 1 day. So genial angle at pod 1 year was decreased about $5.3^{\circ}$ than pre-op genial angle(p<0.01). 2. Mean pre-op gonial angle was $129.4^{\circ}$, showing significantly high value than normal and mean gonial angle at pod 1 year was $124.1^{\circ}$, showing value near to normal. 3. Mean gonial angle change between pre-op and pod 1 year was decreased about $5.4^{\circ}$ in female and $5.3^{\circ}$ in male. There was no statistically significant difference between male and female(p>0.05). 4. Principal factor influencing on decreased gonial angle in gonial angle change between pre-op and pod 1 year was amount of mandibular setback. 5. Principal factor influencing on increased gonial angle in gonial angle change between pod 1 day and pod 1 year was % horizontal relapse, and it was thought that resorption and bone remodelling on posterior area in mandibular distal segment also were related to increased gonial angle. 6. It is thought that sagittal split ramus osteotomy in mandibular prognathic patients with high value of gonial angle is effective to improvement of gonial angle, and In patients who have normal range of gonial angle and are required with excessive mandibular setback, short lingual cut method, additional resection of posterior margin of distal segment, Obwegeser II method will be considerd. 7. More prudent operation and careful post-op management will be responsible for maintenance of postoperative stable gonial angle.

  • PDF

Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes (골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가)

  • Mun, Jun Ki;Son, Sang Jun;Kim, Dae Ho;Seo, Seok Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.145-156
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the efficiency of Split VMAT planning(Contouring rectum divided into an upper and a lower for reduce rectum dose) compare to Conventional VMAT planning(Contouring whole rectum) for prostate cancer radiotherapy involving pelvic lymph nodes. Materials and Methods : A total of 9 cases were enrolled. Each case received radiotherapy with Split VMAT planning to the prostate involving pelvic lymph nodes. Treatment was delivered using TrueBeam STX(Varian Medical Systems, USA) and planned on Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). Lower rectum contour was defined as starting 1cm superior and ending 1cm inferior to the prostate PTV, upper rectum is a part, except lower rectum from the whole rectum. Split VMAT plan parameters consisted of 10MV coplanar $360^{\circ}$ arcs. Each arc had $30^{\circ}$ and $30^{\circ}$ collimator angle, respectively. An SIB(Simultaneous Integrated Boost) treatment prescription was employed delivering 50.4Gy to pelvic lymph nodes and 63~70Gy to the prostate in 28 fractions. $D_{mean}$ of whole rectum on Split VMAT plan was applied for DVC(Dose Volume Constraint) of the whole rectum for Conventional VMAT plan. In addition, all parameters were set to be the same of existing treatment plans. To minimize the dose difference that shows up randomly on optimizing, all plans were optimized and calculated twice respectively using a 0.2cm grid. All plans were normalized to the prostate $PTV_{100%}$ = 90% or 95%. A comparison of $D_{mean}$ of whole rectum, upperr ectum, lower rectum, and bladder, $V_{50%}$ of upper rectum, total MU and H.I.(Homogeneity Index) and C.I.(Conformity Index) of the PTV was used for technique evaluation. All Split VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : Using DVH analysis, a difference between the Conventional and the Split VMAT plans was demonstrated. The Split VMAT plan demonstrated better in the $D_{mean}$ of whole rectum, Up to 134.4 cGy, at least 43.5 cGy, the average difference was 75.6 cGy and in the $D_{mean}$ of upper rectum, Up to 1113.5 cGy, at least 87.2 cGy, the average difference was 550.5 cGy and in the $D_{mean}$ of lower rectum, Up to 100.5 cGy, at least -34.6 cGy, the average difference was 34.3 cGy and in the $D_{mean}$ of bladder, Up to 271 cGy, at least -55.5 cGy, the average difference was 117.8 cGy and in $V_{50%}$ of upper rectum, Up to 63.4%, at least 3.2%, the average difference was 23.2%. There was no significant difference on H.I., and C.I. of the PTV among two plans. The Split VMAT plan is average 77 MU more than another. All IMRT verification gamma test results for the Split VMAT plan passed over 90.0% at 2 mm / 2%. Conclusion : As a result, the Split VMAT plan appeared to be more favorable in most cases than the Conventional VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes. By using the split VMAT planning technique it was possible to reduce the upper rectum dose, thus reducing whole rectal dose when compared to conventional VMAT planning. Also using the split VMAT planning technique increase the treatment efficiency.

  • PDF

A COMPUTERIZED TOMOGRAPHIC STUDY ON THE STRUCTURE OF THE MANDIBULAR RAMUS (전산화단층사진을 이용한 하악지구조분석)

  • Kim, Pyoung-Soo;Ahn, Yung;Jin, Woo-Jeoung;Koh, Kwang-Joon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.4
    • /
    • pp.345-352
    • /
    • 1999
  • This study was conducted for the purpose of suggestion of the new technique of sagittal split ramus osteotomy pararell to the true sagittal plane. This pararellism is the important concept of the sagittal split ramus osteotomy to reduce the condylar sagging including mandibular hypomobility, temporomandibular disorder, occlusal relapse and other complications. We used 26 adult dry manibles(52 rami), and obtained the computed tomographs through the sagittal, horizontal and coronal sections. The results were obtained as follows. 1. On sagittal section, mean area of S1 was $8.63{\pm}2.10cm^2$, S2 was $8.93{\pm}1.94cm^2$, S3 was $9.49{\pm}2.15cm^2$, S6 was $10.72{\pm}2.22cm^2$. The wider area of sagittal section, the more lateral section, But, no significant differency between the areas of the sagittal sections(P>0.05). 2. On horizontal section, The distance between the inferior alveolar canal and the lateral cortical plate of the mandibular ramus were $6.73{\pm}1.24mm$ minum, $7.70{\pm}1.44mm$ maximum. 3. On coronal section, Outer mandibular angle were $4.84{\pm}2.37^{\circ}$ right side, $4.93{\pm}2.12^{\circ}$ left side. 4. The design of the ideal true sagittal split ramus osteotomy is that posterior border of osteotomy must be limited vertically, at the right posterior point of lingula mandibularis and anterior of osteotomy must be extended to mandibular body, anteroinferiorly.

  • PDF

Design, fabrication and performance characteristics of a 50kHz tonpilz type transducer with a half-wavelength diameter (반파장 직경을 갖는 50kHz tonpilz형 음향 변환기의 설계, 제작 및 성능특성)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.2
    • /
    • pp.173-183
    • /
    • 2010
  • In a split beam echo sounder, the transducer design needs to have minimal side lobes because the angular position and level of the side lobes establishes the usable signal level and phase angle limits for determining target strength. In order to suppress effectively the generation of unwanted side lobes in the directivity pattern of split beam transducer, the spacing and size of the transducer elements need to be controlled less than half of a wavelength. With this purpose, a 50 kHz tonpilz type transducer with a half-wavelength diameter in relation to the development of a split beam transducer was designed using the equivalent circuit model, and the underwater performance characteristics were measured and analyzed. From the in-air and in-water impedance responses, the measured value of the electro-acoustic conversion efficiency for the designed transducer was 51.6%. A maximum transmitting voltage response (TVR) value of 172.25dB re $1{\mu}Pa/V$ at 1m was achieved at 52.92kHz with a specially designed matching network and the quality factor was 10.3 with the transmitting bandwidth of 5.14kHz. A maximum receiving sensitivity (SRT) of -183.57dB re $1V/{\mu}Pa$ was measured at 51.45kHz and the receiving bandwidth at -3dB was 1.71kHz. These results suggest that the designed tonpilz type transducer can be effectively used in the development of a split beam transducer for a 50kHz fish sizing echo sounder.

Fish Tracking with a Split Beam Echo Sounder -Measurements of Swimming Speeds- (Split beam 어군탐지기에 의한 어류의 유영행동 조사연구 -유영속도의 측정-)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.301-311
    • /
    • 1999
  • The investigation to evaluate the possible effects of fish behaviour on acoustic target strength was carried out during the 1997 and 1998 hydroacoustic-demersal trawl surveys in the southern waters of Korea.The swimming speed and the target strength of individual, acoustically resolved fished swimming through the sound beam were measured using the split-beam tracking method on board R/V Kaya.The results obtained can be summarized as follows:1. The alongship and athwartship angles between -3dB poionts of a hull mounted 38 kHz split beam tranducer used in these surveys was >$3.76^{\circ}\;and\;6.74^{\circ}$ respectively, and the equal energy contour obtained from the measured beam pattern showed approximately the circular pattern. 2. The swimming speed measured off the south coast of Sorido in 23 January 1997 ranged 0.10 to 0.80 m/s with the average swimming spped of 0.36 m/s, and the target strength ranged -64.8 to -31.7 dB with the average target strength of -52.7 dB. The most dominant species sampled in this survey area were Japanese scaled sardine, Sardinella zunasi and Konoshiro gizzard shad, Konosirus punctatus, respectively.3. The swimming speed measured off the east coast of Kojedo in 24 March 1997 ranged 0.10 to 1.10 m/s with the average swimming speed of 0.40 m/s, and the target strength ranged -64.8 to -51.5 dB with the average target strength of -59.2 dB. The most dominant species sampled in this survey area were Swordtip squid, Photololigo edulis, Konoshiro gizzard shad and Japanese flying squid, Toddarodes pacificus, respectively and the swimming activity of these species seems to be controlled at speeds between 0.20 and 0.60 m/s. 4. The swimming speed measured the south coast of Kojedo in 25 March 1997 ranged 0.10 to 1.40 m/s with the average swimming speed of 0.51 m/s and the target strength ranged -64.3 to -47.7 dB with the average target strength of -55.1 dB. The most dominant species sampled in this survey area were Swordtip squid, Blotchy sillage, Sillago maculata and japanese scaled sardine, respectively and the swimming activity of these species seems to be controlled at speeds between 0.20 and 0.70 m/s.5. The swimming speed measured during morning twilight in the southeastern water of Cheju Island in 11 July 1998 ranged 0.20 to 1.0 m/s with the average swimming speed of 0.53 m/s, and the target strength ranged -65.0 to -47.0 dB with the average target strength of -57.1 dB. The most dominant species sampled in this survey area were Swordtip squid, Black scraper, Thamnaconus modesutus and japanese flying squid, respectively and the tile angle ranged$ +28^{\circ}\;to\;+2^{\circ}$ with the average tilt angle of -8.1$^{\circ}$ showing the downward migration.

  • PDF

Design of a Mandrel for Expansion of the Tube of the Heat Exchanger (열교환기 튜브확관을 위한 맨드렐 설계)

  • Kang, H.S.;Kim, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.430-434
    • /
    • 2004
  • Specifically designed mandrel is needed to expand tube of the heat exchanger with inner grooves. Configuration of the expanded tube depends upon the shape and feeding velocity of the mandrel. 3D simulation software LS-DYNA was used to obtain optimum design conditions of the mandrel. We show how configuration of the expanded tube varies with different design parameters such as the approaching angle, diameter , and the feeding velocity of the mandrel. Material property data for analysis were obtained through experiments with SHPB ( Split Hopkinson Pressure Bars ).

  • PDF