• Title/Summary/Keyword: Split Process

Search Result 301, Processing Time 0.024 seconds

INTEGRATED MAGNETIC SENSORS: AN OVER VIEW

  • Cristolovenau, Sorin
    • The Magazine of the IEIE
    • /
    • v.13 no.1
    • /
    • pp.86-95
    • /
    • 1986
  • The basic physical principles involved in the operation of monolithic magnetic sensors are reviewed and technological aspects outlined. More or less conventional devices based on Hall effect, magnetoresistance or current path deflection are described. It is shown that such sensors with 2, 3, 4 or 5 terminal contacts are achievable with standard silicon integrated circuit process. Several kinds of magnetodiodes (p+nn+,p+n, Schottky, MOS, memory, CMOS) have been fabricated on Si and on SOS films and present attractive properties. Finally, the magneto-transistor family is discussed with emphasis to split-terminals, CMOS, unijunction and fila-mentary devices.

  • PDF

Effect of Spinal Cord Removal before or after Splitting and Washing on CNST Decontamination of Beef Carcasses

  • Lim, D.G.;Kim, D.H.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1770-1776
    • /
    • 2007
  • Beef carcasses were examined to explore the effects of spinal cord removal and washing on central nervous system tissue (CNST) decontamination of the surface during the slaughtering process. A total of 15 carcasses were split by sawing centrally down the vertebral column and left sides of split carcasses were used for analysis. Samples were collected by swabbing the surface from 4 defined parts on the interior and 4 on the exterior of carcasses from the abattoir and analyzed using an ELISA-based test. The results showed that automatic and manual spray washing decreased CNST contamination, especially on the interior ventral parts of carcass surfaces (p<0.01), but did not decrease CNST on the interior dorsal parts. Increasing washing time to 60 s did not affect the reduction of CNST contamination. Samples following spinal cord removal prior to splitting showed lower calculated levels of "risk material" than the stated limit of detection (0.1%) of the ELISA kit on interior and exterior carcass parts (p<0.01). Therefore, spinal cord removal prior to splitting could be a very effective way to minimize CNST contamination of beef carcasses.

An Automated CAD System for Press Die Design in Cold Forging of Axisymmetric Parts (축대칭 제품을 위한 프레스 냉간단조 금형의 자동설계 기술)

  • Kim, Jong-Ho;Ryu, Ho-Yeun;Hong, Ki-Gon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.87-94
    • /
    • 1999
  • The automated die design program is developed for cold forging of axisymmetric parts which are mainly produced by forward extrusion, backward extrusion, composite extrusion and upsetting. For this study, firstly classification of forged parts and investigation of die construction type usually employed in forging industry are carried out and the most proper type from several kinds of die construction is proposed as a standardized one. Based on the die design rules summarized in the references such as handbooks, technical papers, monthly journals, etc. the automated die design program was made using AutoLISP language available in AutoCAD software of personal computer. This program interactively runs for only input data, for example, forging process, shape of forged parts, type of punch, split of die insert and design of shrinkage rings and then displays details of drawings necessary to make a forging die. When a variety of forging processes and forged parts are tested to examine the validity of this program, it was confirmed to give good results applicable to the forging die design in press shop.

  • PDF

Performance of A Three-Stage Condensation Heat Pump

  • Lee, Yoon-Hak;Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.55-68
    • /
    • 1999
  • In this study, computer simulation programs were developed for single-stage, two-stage, and three-stage condensation heat pumps and their performance with CFC11, HCFC123, HCFC141b was examined under the same external conditions. The results showed that the coefficient of performance(COP) of an optimized 'non-split type' three-stage condensation heat pump is 25-42% higher than that of a conventional single-stage heat pump. The increase in COP, however, differed among the fluids tested. The improvement in COP is largely due to the decrease in average LMTDs in condensers, which results in the decrease in thermodynamic irreversibility in heat exchange process. For the three-stage heat pump, the highest COP is achieved when the total condenser area is evenly distributed among the three condensers. For the two-stage heat pump, however, the optimum distribution of the total condenser area varies with an individual working fluid. For the three-stage system, 'splitting the condenser cooling water'for the use of intermediate and high pressure subcoolers helps increase the COP further. When the individual cooling water entering the intermediate and high pressure subcoolers is roughly 10% of the total condenser cooling water, the maximum COP is achieved showing roughly an 11% increase in COP as compared to that of the 'non-split type' heat pump.

  • PDF

Equivalent Circuit Modeling Analysis of Square Split Ring Resonator with Defected Ground Structure (결합 접지면 구조의 사각 분리형 링 공진기의 등가 653회로 모델링 해석)

  • Mun, Seung-Min;Kim, Gir-Re;Yoon, Joong-Han;Choi, Young-Kyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.6
    • /
    • pp.653-658
    • /
    • 2015
  • In this paper, the Square Split Ring Resonator(: SRR) of Defected Ground Structure(: DGS), applicable to MMIC(: Monolithic Microwave Integrated Circuit) design, is proposed. The mathematical method to solve the equivalent parameter of the resonator from the measured results of resonator is introduced in this paper. To verify the method, SRR-DGS resonator with 2.95 GHz center frequency is fabricated, for measuring characteristics and calculating the equivalent parameter. The result from this process is compared with the data of the ADS simulation, and as a result both were identical.

Heat Treatment and Drying Methods of Small-Notched Bamboo for Vertical Flute (단소용 대나무재의 열처리 및 건조)

  • 변희섭;오승원;공태석;김종만
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.3
    • /
    • pp.10-17
    • /
    • 2002
  • This study was carried out to investigate a heat treatment condition and suitable drying schedule of bamboo material(Phyllostachys nigra var. henonis) for a vertical flute with small-notched bamboo. It is very important to prevent drying defects during its drying process. We investigated the effort of heat treatment the most suitable drying schedule for small-notched bamboo vertical flute without drying defects in this research. A direct heat treatment method and drying conditions of 3($20^{\circ}C$ 65%, $40^{\circ}C$ 40%, and dry at air condition) were applied to the Bamboo specimen that felled in several areas for a month. The result suggested that the most suitable drying schedule with the less split and the shortest time was to dry at $40^{\circ}C$, 40% condition and it was useful to direct heat-treatment because of reducing the number and size of split during drying bamboo.

  • PDF

Color Correction with Optimized Hardware Implementation of CIE1931 Color Coordinate System Transformation (CIE1931 색좌표계 변환의 최적화된 하드웨어 구현을 통한 색상 보정)

  • Kim, Dae-Woon;Kang, Bong-Soon
    • Journal of IKEEE
    • /
    • v.25 no.1
    • /
    • pp.10-14
    • /
    • 2021
  • This paper presents a hardware that improves the complexity of the CIE1931 color coordinate algorithm operation. The conventional algorithm has disadvantage of growing hardware due to 4-Split Multiply operations used to calculate large bits in the computation process. But the proposed algorithm pre-calculates the defined R2X, X2R Matrix operations of the conventional algorithm and makes them a matrix. By applying the matrix to the images and improving the color, it is possible to reduce the amount of computation and hardware size. By comparing the results of Xilinx synthesis of hardware designed with Verilog, we can check the performance for real-time processing in 4K environments with reduced hardware resources. Furthermore, this paper validates the hardware mount behavior by presenting the execution results of the FPGA board.

Most suitable design method of post-chlorination process in portable water process by using CFD (전산유체를 활용한 정수공정에서 후염소 투입공정 최적설계 방안)

  • Cho, Youngman
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.331-337
    • /
    • 2013
  • Post-chlorination for disinfection in portable water process is final process. The design factors of post-chlorination are inflow pipe line from tank of filtrated water to cleanwell, injection point of chlorine, appropriate shape of baffle in cleanwell for disinfection efficient improvement. Until now, we did not have the design standard for post-chlorination. we evaluated most suitable design method of post-chlorination process in portable water process by using computational fluid dynamics in this research. We found the result that the pipe to connect the cleanwell should be one. If pipe line split into two or more, uniform distribution of the flow is difficult. Second, optimal injection point of chlorine is the middle of pipe line to connect the cleanwell. Therefore, it is not economical to install chlorine contact basin in cleanwell. Third, the shape of baffle should be designed in order to water flows in one direction. And we found that it is better to design the low number of flow turning.

The pH Value Changes During Wound Healing Process (창상치유 과정에서의 pH 변화)

  • Jeong, Jae Hoon;Lee, Sang Woo;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose: For a proper wound care, the correct evaluation of wound is very important. Usually the evaluation of wound was subjective, and as a result, wound care was empirical. There were many attempts to objectify the wound evaluation, and one of them was measurement of the wound pH. The purpose of this study is to observe the wound pH changes during wound healing phase. Methods: From 2005 to 2007, we measured the pH values of 6 acute wounds, which were split thickness skin graft donor sites. In addition, we measured the pH values of 18 chronic wounds, which were 17 pressure sores and 1 tuberculosis ulcer. After pH meter ($SkinCheck1^{(R)}$, Hanna Instruments, Italy) was calibrated, wound pH was checked. Wound was cleansed with saline gauze and dressed with polyurethane foam dressing($Medifoam^{(R)}$, Biopol, Korea). Results: In split thickness skin graft donor sites, the pH raised(mean pH value: $7.45{\rightarrow}7.62$) when the wound was on the process of healing(*p=0.027, analysis of Wilcoxon signed-rank test). If wound became re-epithelialised, the pH value dropped to that of normal skin. However, we could not find a relation between time and the pH values in chronic wound. Conclusion: We could observe the consistent wound pH changes during wound healing phase in acute wound.

Millimeter-Wave Dielectric Resonator Antennas for the Anti-Collision Car Radar System (차량 충돌 방지 레이더 시스템용 밀리미터파 유전체 공진기 안테나)

  • Park, Young Bon;Jung, Young Ho;Seok, Chang Heon;Lee, Mun Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.41-49
    • /
    • 2013
  • This paper suggests the dielectric resonator antenna using LTCC process for mm-wave car radar system. In this paper, dielectric resonator antennas (DRA) operated in 76-77 GHz frequency band are designed. And, using the LTCC process, the structures of dielectric resonator with SRR (split ring resonator) inside and those of dielectric resonator with probe inside are suggested. Linear polarization antennas and circular polarization antenna are designed for the DRA with probe inside. Three kinds of the DRA antennas are designed and their characteristics are calculated using CST RF simulation tool. The designed antennas are fabricated and measured and the measured results are compared with calculated results. The measured operating frequencies of DRAs are within 76 GHz to 77 GHz, which are close to the calculated results, and the measured gains are about 8.15 dBi to 10.82 dBi.