• Title/Summary/Keyword: Split Plane

Search Result 98, Processing Time 0.03 seconds

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

Comparison of Dynamic Balance Ability and Leg Muscle Properties during Bulgarian Split Squat Exercises using the Visual Block and Unstable Support Plane (시각 차단과 불안정한 지지면을 이용한 불가리안 스플릿 스쿼트 운동 시 동적 균형 능력과 근속성의 비교)

  • Jin-hyun Yang;Gyo-hyeon Lee;Kyung-ho Park;Soo-kyoung Park
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.1
    • /
    • pp.41-52
    • /
    • 2023
  • Background: Bulgarian split squat (BSS) is beneficial to improve dynamic balance ability and muscle activity of lower extremities, however its effects have not been fully investigated. Therefore, this study aimed to compare changes in dynamic balance ability and muscle properties according to various modifications of BSS exercises. Methods: Thirty healthy male volunteers participated in this study, and they were randomly divided into three different groups. The subjects performed the BSS exercise either on a stable surface with the eyes opened (n=10) or eyes closed (n=10), and on an unstable support plane with eyes opened (n=10) conditions, respectively. Dynamic balance ability was measured via Biodex balance system under the eyes-opened and closed conditions. Additionally, muscle properties of the rectus femoris (RF), vastus medialis (VM) and vastus lateralis (VL) were evaluated. Results: Dynamic balance ability did not show the significant differences among the groups that performed the BSS exercises. However, in the Unstable group, there were significant differences in the overall stability index and anterior posterior stability index under the eyes-closed condition between pre-exercise and post-exercise. In comparison of muscle properties according to the groups, RF muscle showed a significant difference in amount of change of elasticity (p=.038). Additionally, there were significant changes in post measurements of VM muscle tone (p=.016), stiffness (p=.012) and elasticity (p=.002). VL muscle, however had no significant differences in muscle properties. Conclusion: These results indicate that BSS exercises could induce the alteration of RF and VM muscle properties, in particular VM muscle which is susceptible to weakness. Thus, BSS could be applied in various ways as an effective rehabilitation exercise.

  • PDF

An Investigation of Roughness Effects on 2-Dimensional Wall Attaching Offset Jet Flow (조도가 2차원 벽부착 제트유동에 미치는 영향에 관한 연구)

  • 윤순현;김대성;박승철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.219-230
    • /
    • 1995
  • The flow characteristics of a two-dimensional offset jet issuing parallel to a rough wall is experimentally investigated by using a split film probe with the modified Stock's calibration method. The mean velocity and turbulent stresses profiles in the up and down-stream locations of the wall-attachment regions are measured and compared with those of the smooth wall attaching offset jet cases. It is found that the wall-attachment region on the rough wall is wider than on the smooth wall for the same offset height and the jet speed. The position of the maximum velocity point is farther away from the wall than that for the smooth wall case because of the thick wall boundary layer established by the surface roughness. It is concluded that the roughness of the wall accelerates the relaxation process to a redeveloped plane wall jet and produces a quite different turbulent diffusion behavior especially near the wall from comparing with the smooth plane wall jet turbulence.

Permittivity Characteristic Analysis of Planar Substrates Using H-shaped Resonant Aperture (H-모양 공진 개구를 이용한 평면 기판의 유전율 특성 분석)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.55-56
    • /
    • 2018
  • In this paper, a method for analyzing the dielectric constant of a planar substrate is proposed. To this end, a band-stop filter was created by adding a H-shaped resonant aperture to the ground plane of a microstrip transmission line. A planar substrate of 2 mm thickness was placed behind the ground plane of the microstrip transmission line and the change of the resonant frequency with the change of the dielectric constant of the substrate was investigated. It can be seen that the change ratio of the frequency to the reference resonant frequency is larger than that of the conventional complementary split ring resonator structure.

  • PDF

Quadruple Band-Notched Trapezoid UWB Antenna with Reduced Gains in Notch Bands

  • Jin, Yunnan;Tak, Jinpil;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2016
  • A compact ultra-wide band antenna with a quadruple band-notched characteristic is proposed. The proposed antenna consists of a slotted trapezoid patch radiator, an inverted U-shaped band stop filter, a pair of C-shaped band stop filters, and a rectangular ground plane. To realize the quadruple notch-band characteristic, a U-shaped slot, a complementary split ring resonator, an inverted U-shaped band stop filter, and two C-shaped band stop filters are utilized in this antenna. The antenna satisfies the -10 dB reflection coefficient bandwidth requirement in the frequency band of 2.88-12.67 GHz, with a band-rejection characteristic in the WiMAX (3.43-3.85 GHz), WLAN (5.26-6.01 GHz), X-band satellite communication (7.05-7.68 GHz), and ITU 8 GHz (8.08-8.87 GHz) signal bands. In addition, the proposed antenna has a compact volume of $30mm{\times}33.5mm{\times}0.8mm$ while maintaining omnidirectional patterns in the H-plane. The experimental and simulated results of the proposed antenna are shown to be in good agreement.

SKELETAL RELAPSE AFTER ORTHOGNATHIC SURGERY OF CLASS III SKELETAL OPEN-BITE (개구교합을 가진 3급 부정교합환자의 악교정수술후 재발에 관한 연구)

  • Song, Jae-Chul;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.3
    • /
    • pp.229-237
    • /
    • 1993
  • This study was intended to evaluate a post-operative relapse tendency in mandibular prognathism patients with open-bite. 18 patients with or without open-bite have undergone sagittal split ramus osteotomy and were investigated radiologically with cephalogram. The results were as following 1. The preoperative anterior facial height, mandibular plane angle and mandibular gonial angle were larger in open-bite patients than in nonopen-bite patients.(p>0.05) 2. There was significant correlation between surgical change of SNA, mandibular plane length and long-term relapse.(p<0.01). 3. There was relatively stable postoperative anterior facial height in open bite patients. 4. There was no significant correlation between the surgical change of mandibular plane angle, amount of mandibular setback and long-term relapse.(p>0.01) 5. This study showed that horizontal relapse was more significant than vertical relapse.

  • PDF

Buttock Augmentation with Elastomer Implants (엘라스토머 임플란트를 사용한 엉덩이 확대 성형술)

  • Park, Bong-Kwon;Kim, Youn-Hwan;Ahn, Hee-Chang
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • Purpose: The buttocks region has been associated with allure and sex appeal for centuries. Gluteal implants enable buttocks remodeling in a way that is not possible in other methods. One of the reasons that render gluteal implant surgeries unpopular is the fear of complications, the main problems being seroma, wound dehiscence, extrusion, and a visible or palpable implant. The authors present the XYZ technique, which provides anatomical reference points to guide the intramuscular dissection procedure in a feasible and safe way, resulting in a lower complication rate. Methods: The XYZ procedure was done for buttock augmentation on 8 patients from December 2009 to June 2010. Patient's ages ranged from 27 to 44 with a mean age of 36. Seven patients were applied the 250cc sized Elastomer implants with one patient 290cc sized implant. Preoperative marking was done with the patients in the standing position. Bisection of the gluteus maximus muscle was done at the midpoint thickness to create a plane for implant insertion, which is called the sandwich plane. Results: The 8 cases were performed safely without major complications. However one patient had minor wound dehiscence, and was managed with conservative treatment. Another patient had a discomfort on the buttocks for a long time. The patients were followed up for average 6 months. All patients were satisfied with the aesthetic results. Conclusion: In performing the XYZ technique for gluteal augmentation, the surgeon must split the muscle into two equal halves with anatomical reference points to guide the muscle detachment in a symmetrical way at an adequate depth. This method provides a guideline for the surgeon in determining the ideal plane during intramuscular dissection and gives predictable results with low complication rates. Intramuscular gluteoplasty with gluteal implants offers predictable, aesthetically pleasing results without contour irregularities and only a low incidence of major complications.

THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT (3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구)

  • Lee, Sang-Han;Nam, Jeong-Hun;Jung, Chang-Wook;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

Accurate transfer of bimaxillary orthognathic surgical plans using computer-aided intraoperative navigation

  • Chen, Chen;Sun, Ningning;Jiang, Chunmiao;Liu, Yanshan;Sun, Jian
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.321-328
    • /
    • 2021
  • Objective: To examine the accuracy of computer-aided intraoperative navigation (Ci-Navi) in bimaxillary orthognathic surgery by comparing preoperative planning and postoperative outcome. Methods: The study comprised 45 patients with congenital dentomaxillofacial deformities who were scheduled to undergo bimaxillary orthognathic surgery. Virtual bimaxillary orthognathic surgery was simulated using Mimics software. Intraoperatively, a Le Fort I osteotomy of the maxilla was performed using osteotomy guide plates. After the Le Fort I osteotomy and bilateral sagittal split ramus osteotomy of the mandible, the mobilized maxilla and the distal mandibular segment were fixed using an occlusal splint, forming the maxillomandibular complex (MMC). Real-time Ci-Navi was used to lead the MMC in the designated direction. Osteoplasty of the inferior border of the mandible was performed using Ci-Navi when facial symmetry and skeletal harmony were of concern. Linear and angular distinctions between preoperative planning and postoperative outcomes were calculated. Results: The mean linear difference was 0.79 mm (maxilla: 0.62 mm, mandible: 0.88 mm) and the overall mean angular difference was 1.20°. The observed difference in the upper incisor point to the Frankfort horizontal plane, midfacial sagittal plane, and coronal plane was < 1 mm in 40 cases. Conclusions: This study demonstrates the role of Ci-Navi in the accurate positioning of bone segments during bimaxillary orthognathic surgery. Ci-Navi was found to be a reliable method for the accurate transfer of the surgical plan during an operation.

Theory and Practice in the Tensile Strength Test for Split Ring Shaped Rock Specimen (터진고리 형태의 암석시편에 대한 인장강도 시험의 이론과 실제)

  • Choi, Byung-Hee;Lee, Youn-Kyou;Park, Chan;Park, Chulwhan
    • Explosives and Blasting
    • /
    • v.38 no.1
    • /
    • pp.30-37
    • /
    • 2020
  • In this study the split ring (SR) test was investigated for its applicability to the measurement of the tensile strength of rock specimen of NX size. The concept of the SR test is the same as the half ring (HR) test (Choi et al., 2019) except that the expected fracture plane is perpendicular to the loading direction. Because of this perpendicularity, however, it was believed that the SR test could be more accurate than the HR test. Like the HR specimen, the SR specimen is a curved prismatic bar with a uniform section. Appealing to a basic bending theory in strength of materials, the tensile strength for the special bar can be calculated analytically. Numerical simulations using LS-DYNA revealed, as expected, that the strength errors were 1% and 5% for the tensional and compressional SR tests, respectively, which were much lower than that (12%) of the HR test. To identify the performance of the two SR tests, laboratory experiments were conducted. The HR and Brazilian tests were also performed for comparison. The experiments showed that the ratios of the tensional and compressional SR to Brazilian strengths were 1.2~1.4 and 1.1~1.2, respectively, which are too small compared to empirical values in ordinary bend tests. Consequently, it is concluded that the SR test is not appropriate for use in tensile strength test of rock specimen of NX size. But the ratio of the HR to Brazilian strengths was within 1.7~2.0 for both the previous and present studies, showing a good consistency in their test results.