• Title/Summary/Keyword: Spiral tests

Search Result 61, Processing Time 0.028 seconds

A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer - (터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 -)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

Effect of Vertically Rising Pressure Providing Spinal Canal Segment Motion on Symptom Relief in Patients with Parkinson's Disease (척추관 분절운동을 제공하는 수직 상승 압력이 파킨슨병 환자의 증상 완화에 미치는 영향)

  • Do-Hyun, Ahn;Hyeun-Woo, Choi;Kyung-Mi, Jung;Na-Young, Kim;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.787-797
    • /
    • 2022
  • The purpose of this study was to confirm the reduction of pain and symptom relief of Parkinson's disease by vertically stimulating the spine through the application of a mechanical bed capable of thermal and massage stimulation. For this purpose, after confirming the segmental motion of the spine due to the use of a medical combination stimulation bed for Parkinson's disease patients, VAS, ODI, gait ability, and spiral drawing tests were performed, and the relationship between the variables was identified. In the 10-day visual analog scale and evaluation of low back pain dysfunction, the average trend of decreasing after bed use was confirmed. For walking ability, a decrease in the moving time and an increase in the moving distance were observed. In the spiral drawing test, the mean test time after using bed was significantly lower than before. As a result, it suggested the possibility of using it as an auxiliary method for recovery and pain relief of Parkinson's disease patients due to spinal segmental movement with mechanical heating and massage. However, this study is a preliminary study, and there is a small number of subjects, so additional research is needed that considers the number and condition of future subjects in detail.

Design Improvement of Baffle Injector Using Conjugate Heat Transfer Analysis (복합열전달 해석을 이용한 배플 분사기 설계 개선)

  • Kim, Seong-Ku;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.4
    • /
    • pp.395-402
    • /
    • 2010
  • Baffle injectors are protruded into the combustion chamber and form an anti-pulsating baffle to prevent high-frequency combustion instabilities in transverse modes. Being exposed to a high heat-flux environment, the baffle injector has self-cooling passages through which kerosene is convected and heated. The baffle injector with 20 spiral cooling channels has been developed and successfully applied to 30 $ton_f$-class combustors without any performance loss due to an additional cooling. In this work, numerical analysis of conjugate heat transfer in baffle injectors with various cooling channel designs has been performed in order to reduce the fabrication cost which would be considerably increased for the 75 $ton_f$-class combustor. Prior to the application to a full-scale combustor, the thermal durability of the modified design has been verified through the subscale hot-firing tests.

Evolution of Interferon-Gamma Release Assay Results and Submillisievert Chest CT Findings among Close Contacts of Active Pulmonary Tuberculosis Patients

  • Yoon, Soonho;Mihn, Do-CiC;Song, Jin-Wha;Kim, Sung A;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.4
    • /
    • pp.283-288
    • /
    • 2020
  • Background: Latent tuberculosis (TB) infection among TB contacts is diagnosed using plain chest radiography and interferon-gamma release assays (IGRAs). However, plain chest radiographs often miss active TB, and the results of IGRA could fluctuate over time. The purpose of this study was to elucidate changes in the results of the serial IGRAs and in the findings of the serial submillisievert chest computed tomography (CT) scans among the close contacts of active pulmonary TB patients. Methods: Patients age 20 or older with active pulmonary TB and their close contacts were invited to participate in this study. Two types of IGRA (QuantiFERON-TB Gold In-Tube assay [QFT-GIT] and the T-SPOT.TB test [T-SPOT]) and submillisievert chest CT scanning were performed at baseline and at 3 and 12 months after enrollment. Results: In total, 19 close contacts participated in this study. One was diagnosed with active pulmonary TB and was excluded from further analysis. At baseline, four of 18 contacts (22.2%) showed positive results for QFT-GIT and T-SPOT; there were no discordant results. During the follow-up, transient and permanent positive or negative conversions and discordant results between the two types of IGRAs were observed in some patients. Among the 17 contacts who underwent submillisievert chest CT scanning, calcified nodules were identified in seven (41.2%), noncalcified nodules in 14 (82.4%), and bronchiectasis in four (23.5%). Some nodules disappeared over time. Conclusion: The results of the QFT-GIT and T-SPOT assays and the CT images may change during 1 year of observation of close contacts of the active TB patients.

Experimental and numerical research on the behavior of steel-fiber-reinforced-concrete columns with GFRP rebars under axial loading

  • Iman Saffarian;Gholam Reza Atefatdoost;Seyed Abbas Hosseini;Leila Shahryari
    • Structural Engineering and Mechanics
    • /
    • v.86 no.3
    • /
    • pp.399-415
    • /
    • 2023
  • This paper presents the experimental and numerical evaluations on the circular SFRC columns reinforced GFRP rebars under the axial compressive loading. The test programs were designed to inquire and compare the effects of different parameters on the columns' structural behavior by performing experiments and finite element modeling. The research variables were conventional concrete (CC), fiber concrete (FC), types of longitudinal steel/GFRP rebars, and different configurations of lateral rebars. A total of 16 specimens were manufactured and categorized into four groups based on different rebar-concrete arrangements including GRCC, GRFC, SRCC, and SRFC. Adding steel fibers (SFs) into the concrete, it was essential to modify the concrete damage plastic (CDP) model for FC columns presented in the finite element method (FEM) using ABAQUS 6.14 software. Failure modes of the columns were similar and results of peak loads and corresponding deflections of compression columns showed a suitable agreement in tests and numerical analysis. The behavior of GFRP-RC and steel-RC columns was relatively linear in the pre-peak branch, up to 80-85% of their ultimate axial compressive loads. The axial compressive loads of GRCC and GRFC columns were averagely 80.5% and 83.6% of axial compressive loads of SRCC and SRFC columns. Also, DIs of GRCC and GRFC columns were 7.4% and 12.9% higher than those of SRCC and SRFC columns. Partially, using SFs compensated up to 3.1%, the reduction of the compressive strength of the GFRP-RC columns as compared with the steel-RC columns. The effective parameters on increasing the DIs of columns were higher volumetric ratios (up to 12%), using SFs into concrete (up to 6.6%), and spiral (up to 5.5%). The results depicted that GFRP-RC columns had higher DIs and lower peak loads compared with steel-RC columns.

Susceptibility of various Helicobacter pyloris to New Antiulcer Agents

  • Tae W. Woo;Han Y. Yoo;Man S. Chang;Young K. Chung;Kim, Kyu B.;Sang K. Son;Kim, Sung K.;Dae P. Kang;Park, Whan S.
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.197-197
    • /
    • 1996
  • Helicobacter pylori (H. pylori) is a microaerophilic spiral bacterium and infection by it in the human stomach causes gastritis, furthermore, it is considered to be involved in the pathogenesis of peptic ulcers and the development of gastric carcinoma. We assessed the inhibitory activity of new antiulcer drugs against Helicobacter pylori. The activities of new antiulcer agents against Helicobacter pylori strains were determined by the standard agar dilution method with blood agar base #2, supplemented with 5% sheep blood and 4 antibiotics to support growth of these organisms. They were inoculated by multipoint inoculator and incubated at 37$^{\circ}C$ for 3 days under microaerophilic atmosphere. The MIC of antiulcer agents was the lowest concentration that inhibited visible growth of these organisms. According to results of various biochemical tests, these bacteria were identified as Helicobacter pylori strains. And the MIC results showed that the strains were very susceptible to omeprazole and YJA20379s. Some of YJA20379s were more potent than omeprazole. These results suggest that our new antiulcer drugs have potent inhibitory activity against Helicobacter pylori, so that our new antiulcer drugs might be useful for the clinical eradication of gastrointestinal Helicobacter pylori.

  • PDF

Experimental research on the behavior of circular SFRC columns reinforced longitudinally by GFRP rebars

  • Iman Saffarian;Gholam Reza Atefatdoost;Seyed Abbas Hosseini;Leila Shahryari
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.513-525
    • /
    • 2023
  • This research presents the experimental and theoretical evaluations on circular steel-fiber-reinforced-concrete (SFRC) columns reinforced by glass-fiber-reinforced-polymer (GFRP) rebar under the axial compressive loading. Test programs were designed to investigate and compare the effect of different parameters on the structural behavior of columns by performing tests. Theses variables included conventional concrete (CC), fiber concrete (FC), steel/GFRP longitudinal rebars, and transversal rebars configurations. A total of 16 specimens were constructed and categorized into four groups in terms of different rebar-concrete configurations, including GFRP-rebar-reinforced-CC columns (GRCC), GFRP-rebar-reinforced-FC columns (GRFC), steel-rebar-reinforced-CC columns (SRCC) and steel-rebar- reinforced-FC columns (SRFC). Experimental observations displayed that failure modes and cracking patterns of four groups of columns were similar, especially in pre-peak branches of load-deflection curves. Although the average ultimate axial load of columns with longitudinal GFRP rebars was obtained by 17.9% less than the average ultimate axial load of columns with longitudinal steel rebars, the average axial ductility index (DI) of them was gained by 10.2% higher than their counterpart columns. Adding steel fibers (SFs) into concrete led to the increases of 7.7% and 6.7% of the axial peak load and the DI of columns than their counterpart columns with CC. The volumetric ratio had greater efficiency on peak loads and DIs of columns than the type of transversal reinforcement. A simple analytical equation was proposed to predict the axial compressive capacity of columns by considering the axial involvement of longitudinal GFRP rebars, volumetric ratio, and steel spiral/hoop rebar. There was a good correlation between test results and predictions of the proposed equation.

Effects of Flow Rate of Feed Kanjang and Volume Reduction Ratio of Retentate on the Permeate Flux and Rejection of Microbes Cells and Components in Kanjang during Ultrafiltration Operations (재래식 간장의 한외여과시 공급액의 주입속도와 잔류액의 용량감소율이 간장의 투과유속, 미생물균체 및 성분저지율에 미치는 영향)

  • Kwon, Kwang-Il;Lee, Jong-Gu;Choi, Jong-Dong;Chung, Hyun-Chae;Im, Moo-Hyeog;Kim, Ki-Ju;Kim, Woo-Seong;Sung, Jun-Hyun;Kwon, O-Jun;Kim, Young-Ji;Suh, Chung-Sik;Choi, Cheong;Choi, Kwang-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.72-76
    • /
    • 2003
  • Ultrafiltration (UF) tests performed on traditional soy sauce (kanjang) using UF flat membrane test cell unit with thin film laminar flow similar to the spiral type membrane module in batch operations revealed reduction in permeate flux is proportional to the logarithm values of volume reduction ratio of the retentate kanjang at different feed rate of kanjang. Feed rate of 1.5 L/min was found to be adequate for long-term UF operation of kanjang using the test unit attached with MW cut-off size of 200,000 dalton polyoleffin plastic membrane in batch operation with the least concentration polarization. The higher the feed rate of kanjang, the lower the permeability of total nitrogen and NaCl, resulting in lower optical density at 500 nm and lower permeability of minerals such as Cu, Mn, and Mg. Microbial cells were completely rejected regardless of the feed rate, whereas most free amino acids were not.

Clinical Usefulness of D-dimer Test with Semiquantitative Latex Agglutination Method in Pulmonary Embolism (폐색전증에서 반정량적 Latex 응집법으로 시행한 D-dimer 검사의 유용성에 관한 연구)

  • Kim, Dong Kyun;Chun, Kang Il;Kim, Yang-Ki;Lee, Young-Mok;Kim, Ki Up;Uh, Soo-taek;Kim, Yong Hoon;Park, Choon Sik;Park, No Jin;Choi, Tae Youn
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.651-655
    • /
    • 2005
  • Background : Diagnosing a pulmonary embolism is difficult because its presenting symptoms are nonspecific and there are limitations with all of the objective tests. The D-dimer is known to be a marker of the lysis of intravascular cross-linked fibrin as a result of the activation of the endogenous fibrinolytic pathways, and the D-dimer assay is these an objective method for diagnosing a pulmonary embolism. This study assessed the benefits of the D-dimer test for diagnosing a pulmonary embolism using semiquantitative latex agglutination. Methods : The latex agglutination results of 185 patients were retrospectively reviewed. The D-dimer test was performed at the time a pulmonary embolism was suspected. Ninety patients(group I) were diagnosis with PE through spiral chest CT or a chest CT angiogram, perfusion/ventilation scans, and/or pulmonary angiogram. Ninety-five patients (group II) were found not to have a pulmonary embolism through the above tests. Results : The male to female ratio and mean age in groups I and II was 37:55, and 57 years old to 50:45 and 52 years old, respectively. When the cut off value for a positive D-dimer assay was set to $500{\mu}g$, the sensitivity, positive predictive value, negative predictive value and specificity was 86.7%, 61.4%, 79.3%, and 48.4%, respectively. Conclusion : The semiquantitative latex agglutination method in the D-dimer test has a lower sensitivity and negative predictive value than the well known ELISA test particularly for small emboli. Therefore, this test is not a suitable screening test for excluding a pulmonary embolism.