• 제목/요약/키워드: Spiral Tube

검색결과 87건 처리시간 0.024초

운전조건에 따른 펌프 터빈 시스템의 안정성 연구 (Reliability Investigation of a Pump-Turbine System at Various Operating Conditions)

  • 천청청;패트릭마크싱;최영도
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.46-52
    • /
    • 2015
  • Pump-turbine system is widely used by the hydropower industry for stabilizing the electrical grid in the vast growing economy of most developed countries. This study only investigates the Fluid-structure Interaction (FSI) analysis of the pump-turbine system at various operating conditions. The FSI analysis can show how reliable each component of the system is by providing the engineer with a better understanding of high stress and deformation points, which could reduce the lifespan of the pump-turbine. Pump-turbine components are categorized in two parts, pressurized static parts and movable stressed parts. The fixed parts include the spiral casing, top and bottom cover, stay vane and draft tube. The movable parts include guide vanes and impeller blades. Fine hexahedral numerical grids were used for CFD calculation and fine tetrahedral grids were used for structural analysis with imported load solution mapping greater than 90 %. The maximum equivalent stress are much smaller than the material yield stress, and the maximum equivalent stress showed an increasing tendency with the varying of operating conditions from partial to excessive at both modes. In addition, the total deformation of all the operating conditions showed a small magnitude, which have quite small influence on the structural stability. It can be conjectured that this system can be safely implemented.

이매패류 3종 (꼬막, 지중해담치, 개조개) 의 당면체 형태 (Crystalline Style Morphology in Three Species of Bivalve (Tegillarca granosa, Mytilus galloprovincialis and Saxidomus purpuratus))

  • 주선미;박지선;이정식
    • 한국패류학회지
    • /
    • 제26권2호
    • /
    • pp.165-170
    • /
    • 2010
  • 서식지가 서로 다른 이매패류 3종 (꼬막, 지중해담치 및 개조개)의 당면체낭의 위치와 당면체를 형태학적인 측면에서 기재하였다. 당면체낭은 후위와 연결되어 있었으며, 당면체는 당면체낭에 위치하고 있었다. 3종의 당면체는 반투명의 젤라틴 형태의 긴 원뿔형으로 탄성을 가지고 있었다. 꼬막과 지중해담치의 당면체 내부에는 적황색의 나선형 필라멘트가 존재하며, 개조개의 당면체에는 기저부에서부터 말단부까지 희고 긴 관이 존재하였다. 각장에 대한 당면체의 상대길이비는 꼬막은 47.69, 개조개는 64.20%였으며, 지중해담치의 각고에 대한 상대길이비는 48.97%였다. 육중량에 대한 당면체의 상대무게비는 꼬막과 지중해담치는 0.54%였으며, 개조개는 0.39%였다.

한국형발사체 3단 터빈배기부 개념설계 (Conceptual Design of Turbine Exhaust System for 3rd stage of Launch Vehicle)

  • 신동순;김경석;한상엽;방정석;김현웅;조동혁
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1068-1071
    • /
    • 2017
  • 3단 터빈배기부 구성은 터빈 플랜지, 열교환기, 배기덕트와 추력노즐로 이루어진다. 냉가스 가압 방식에 비하여 열교환기 가압 방식을 사용함으로서 추진제탱크 가압을 위한 헬륨가스 자체 무게와 저장 탱크 무게가 감소하는 장점이 있기 때문에 발사체에 열교환기를 사용한다. 가스발생기는 추진제 연료과농 조건에서 연소가 이루어지며, 연소가스 중에 그을음이 많이 포함되어 있기 때문에 열교환 효율이 감소하는 것을 고려하여 열교환기를 설계해야 한다. 본 논문에서는 터빈배기부 구성품 배치, 열교환기 내부 구조 및 제작성을 고려한 설계기법, 기 설계된 노즐 설계를 바탕으로 3단 터빈배기부 재 노즐 설계 형상에 대한 장점을 기술하였다.

  • PDF

Evolution of Interferon-Gamma Release Assay Results and Submillisievert Chest CT Findings among Close Contacts of Active Pulmonary Tuberculosis Patients

  • Yoon, Soonho;Mihn, Do-CiC;Song, Jin-Wha;Kim, Sung A;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권4호
    • /
    • pp.283-288
    • /
    • 2020
  • Background: Latent tuberculosis (TB) infection among TB contacts is diagnosed using plain chest radiography and interferon-gamma release assays (IGRAs). However, plain chest radiographs often miss active TB, and the results of IGRA could fluctuate over time. The purpose of this study was to elucidate changes in the results of the serial IGRAs and in the findings of the serial submillisievert chest computed tomography (CT) scans among the close contacts of active pulmonary TB patients. Methods: Patients age 20 or older with active pulmonary TB and their close contacts were invited to participate in this study. Two types of IGRA (QuantiFERON-TB Gold In-Tube assay [QFT-GIT] and the T-SPOT.TB test [T-SPOT]) and submillisievert chest CT scanning were performed at baseline and at 3 and 12 months after enrollment. Results: In total, 19 close contacts participated in this study. One was diagnosed with active pulmonary TB and was excluded from further analysis. At baseline, four of 18 contacts (22.2%) showed positive results for QFT-GIT and T-SPOT; there were no discordant results. During the follow-up, transient and permanent positive or negative conversions and discordant results between the two types of IGRAs were observed in some patients. Among the 17 contacts who underwent submillisievert chest CT scanning, calcified nodules were identified in seven (41.2%), noncalcified nodules in 14 (82.4%), and bronchiectasis in four (23.5%). Some nodules disappeared over time. Conclusion: The results of the QFT-GIT and T-SPOT assays and the CT images may change during 1 year of observation of close contacts of the active TB patients.

파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화 (Volume Change of Spiral Computed Tomography due to the Changed in the Parameters)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.307-311
    • /
    • 2013
  • 본 논문에서는 피폭선량 절감을 위해 기존의 선량보다 낮은 선량으로 CT검사를 했을 경우에 병변의 유무를 충분히 가릴 수 있는지 scan parameter(절편두께, Helical Pitch)와 3차원으로 영상재구성시 threshold값의 설정에 따른 영상의 변화정도를 3차원 영상화를 통하여 시료의 체적 변화를 알아보고, 피폭선량절감을 위한 CT에서 허용 가능한 scan parameter를 찾고자 연구를 시도하였다. 실험방법으로는 실리콘을 이용하여 시료를 제작하였으며, 이때 시료의 크기는 직경이 50, 40, 30, 20, 10mm로 10mm 간격으로 5개의 구형 모형을 제작하였고, 5개의 시료를 관전압, 관전류를 각각 120Kvp, 50mA로 고정하고, 단면두께(1.0, 2.0, 3.0, 5.0, 7.0mm), Helical Pitch(1.5, 2.0, 3.0)를 각각 변화시켜 Scan 하고 영상 간의 interval은 (1.0, 2.0, 3.0, 5.0, 7.0mm)로 구성하여, 영상을 workstation으로 전송하고, Volume Rendering Technique를 사용하여 threshold(-200,-50,50 ~1,000) 값을 변화시키면서 3차원 영상으로 재구성하고, 시료의 체적을 측정하였다. 실험결과 Helical pitch가 1.5일 때 체적변화가 가장 적었고, Helical pitch가 3.0일 때 체적변화가 가장 많이 감소하였으며, 절편두께가 증가할수록 시료의 체적도 실측치보다 감소한다는 것을 실험을 통해 확인 할 수 있었다. 또한 3차원 영상재구성시 threshold 범위를 -200~1,000으로 설정한 경우, 시료의 체적의 변화가 가장 적은 것으로 나타났다.

Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정 (Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test)

  • 김철웅;임세호;신동록;이지영;박재한;안윤희;고광백
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

체질량지수에 따른 심장 CT검사의 수동노출조절 방법과 자동노출조절 방법의 방사선량 및 화질 평가 (Evaluation of Radiation Dose and Image Quality Between Manual and Automatic Exposure Control Mode According to Body Mass Index in Cardiac CT)

  • 김형진;문일봉;한재복;최남길;장성주
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.290-299
    • /
    • 2013
  • 건강검진 목적으로 심장 CT검사를 시행한 198명의 대상자 중 수동노출조절 방법(n=123)의 대조군과 자동노출조절 방법(n=75)의 실험군으로 BMI에 따라 Grade 1(BMI < 23kg/$m^2$), Grade 2(23 $$\leq_-$$ BMI < 25kg/$m^2$), Grade 3(25 $$\leq_-$$ BMI < 30kg/$m^2$), Grade 4(30 $$\leq_-$$ BMI kg/$m^2$)로 분류하고 영상의 질을 객관적, 주관적 평가로 분석하였고 방사선량을 비교하였다. 자동노출조절 방법을 사용하였을 때 모든 Grade에서 관전압이 유의하게 감소하였고, $CTDI_{vol}$, effective dose 값은 Grade 2에서는 통계적으로 유의하지 않게 감소하였으나 Grade 1, 3, 4에서는 유의하게 감소하였다(p<0.05). SNR은 Grade 1에서 유의하게 감소하였고 Grade 3에서는 유의하게 증가하였지만(p<0.05) Grade 2와 4에서는 유의한 차이가 없었다(p>0.05). CNR은 Grade 1에서 유의하게 감소하였고(p<0.05), Grade 2, 3, 4에서는 유의한 차이는 없었다(p>0.05). 영상의 주관적인 평가에서도 두 그룹간의 모든 Grade에서 유의한 차이가 없었다(p>0.05). 결론적으로 자동노출조절 방법은 수동노출조절 방법에 비해 영상의 주관적 평가는 변하지 않으면서도 피폭선량을 줄일 수 있는 유용한 방법으로 나타났다.