• Title/Summary/Keyword: Spinal cord min]v

Search Result 18, Processing Time 0.02 seconds

Effects of GaAsAl laser on the spinal neuronal activity induced by noxious mechanical stimulation (GaAsAl 레이저가 물리적 통증반응과 관련된 척수내 신경세포의 활성에 미치는 영향)

  • Song, Young-Wha;Lee, Young-Gu;Lim, Jong-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.545-558
    • /
    • 2000
  • The present study was designed to investigate the effect of low power GaAsAl laser on Fos expression in the spinal cord induced by noxious mechanical stimulation. Noxious mechanical stimulation was applied to the right hind paw following 30min of low power laser treatment using different intensity and treatment point and the resulting Fos expression in the spinal cord dorsal horn was compared to that obtained in rats exposed only to the noxious mechanical stimulation. The results were summarized as follows: 1. In intact control rats, only a few Fos like immunoreactive(Fos-IR) neurons were evident in the lumbar spinal cord dorsal horn. Similarly, following prolonged inhalation anesthesia, Fos-IR neurons were absent in the dorsal horn of the lumbar spinal cord. In animals treated with noxious mechanical stimulation, neurons with nuclei exhibiting Fos immunostaining were distributied mainly in the medial half of ipsilateral laminae I-V at lumbar segments L3-5. These findings directly indicated that prolonged anesthesia used in this study did not affect the Fos expression in the spinal cord dorsal horn of intact animals and noxious mechanical stimulation treated animals. 2. In acupoint treated animals, 10mW of laser stimulation, not 3mW intensity, significantly reduced the number of Fos immunoreactive neurons in the spinal dorsal horn induced by noxious mechanical stimulation(P<.01). However, the supressive effect of low power laser stimulatin was not observed in 3m Wand 10m W of laser stimulation into non-acupoint. These data indicate that 10mW of low power laser stimulation into acupoint is capable of inhibiting the expression of Fos in the dorsal horn induced by noxious mechanical stimulation. In conclusion, these findings raise the possibility that low power laser stimulation into acupoint may be a promising alternative medicine therapy for the mechanical stimulation induced pain in the clinical field.

  • PDF

Effect of Electrical Stimulation of Peripheral Nerve on Pain Reaction (말초신경자극이 동통반응에 미치는 영향)

  • Paik, Kwang-Se;Chung, Jin-Mo;Nam, Taick-Sang;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.15 no.2
    • /
    • pp.73-81
    • /
    • 1981
  • Experiments were conducted in ischemic decerebrate cats to study the effects of electroacupuncture and electrical stimulation of peripheral nerve on pain reaction. Flexion reflex was used as an index of pain. The reflex was elicited by stimulating the sural nerve(20 V, 0.5 msec duration) and recorded as a compound action potential from the nerve innervated to the semitendinosus muscle. Electroacupuncture was performed, using a 23-gauge hyperdermic needle, on the tsusanli point in the lateral upper tibia of the ipsilateral hindlimb. The common peroneal nerve was selected as a peripheral nerve which may be associated with electroacupuncture action, as it runs through the tissue portion under the tsusanli point. Both for electroacupuncture and the stimulation of common peroneal nerve a stimulus of 20 V-intensity, 2 msec-duration and 2 Hz-frequency was applied for 60 min. The results are summerized as follows: 1) The electroacupuncture markedly depressed the flexion reflex; this effect was eliminated by systemic application of naloxone $(0.02{\sim}0.12\;mg/kg)$, a specific narcotic antagonist. 2) Similarly, the electrical stimulation of the common peroneal nerve significantly depressed the flexion reflex, the effect being reversed by naloxone. 3) When most of the afferent nerves excluding sural nerve in the ipsilateral hindlimb were cut, the effect of electroacupuncture on the flexion reflex was not observed. Whereas direct stimulation of the common peroneal nerve at the proximal end from the cut resulted in a significant reduction of the flexion reflex, again the effect was reversible by naloxone application. 4) Transection of the spinal cord at the thoracic 12 did not eliminate the effect of peripheral nerve stimulation on the flexion reflex and its reversal by naloxone, although the effect was significantly less than that in the animal with spinal cord intact. These results suggest that: 1) the analgesic effect of an electroacupuncture is directly mediated by the nervous system and involves morphine-like substances in CNS, 2) the site of analgesic action of electroacupuncture resides mainly in the brainstem and in part in the spinal cord.

  • PDF

Single-Channel Recording of TASK-3-like $K^+$ Channel and Up-Regulation of TASK-3 mRNA Expression after Spinal Cord Injury in Rat Dorsal Root Ganglion Neurons

  • Jang, In-Seok;La, Jun-Ho;Kim, Gyu-Tae;Lee, Jeong-Soon;Kim, Eun-Jin;Lee, Eun-Shin;Kim, Su-Jeong;Seo, Jeong-Min;Ahn, Sang-Ho;Park, Jae-Yong;Hong, Seong-Geun;Kang, Da-Won;Han, Jae-Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.12 no.5
    • /
    • pp.245-251
    • /
    • 2008
  • Single-channel recordings of TASK-1 and TASK-3, members of two-pore domain $K^+$ channel family, have not yet been reported in dorsal root ganglion (DRG) neurons, even though their mRNA and activity in whole-cell currents have been detected in these neurons. Here, we report single-channel kinetics of the TASK-3-like $K^+$ channel in DRG neurons and up-regulation of TASK-3 mRNA expression in tissues isolated from animals with spinal cord injury (SCI). In DRG neurons, the single-channel conductance of TASK-3-like $K^+$ channel was $33.0{\pm}0.1$ pS at - 60 mV, and TASK-3 activity fell by $65{\pm}5%$ when the extracellular pH was changed from 7.3 to 6.3, indicating that the DRG $K^+$ channel is similar to cloned TASK-3 channel. TASK-3 mRNA and protein levels in brain, spinal cord, and DRG were significantly higher in injured animals than in sham-operated ones. These results indicate that TASK-3 channels are expressed and functional in DRG neurons and the expression level is up-regulated following SCI, and suggest that TASK-3 channel could act as a potential background $K^+$ channel under SCI-induced acidic condition.

Evaluation of the hybrid-dynamic conformal arc therapy technique for radiotherapy of lung cancer

  • Kim, Sung Joon;Lee, Jeong Won;Kang, Min Kyu;Kim, Jae-Chul;Lee, Jeong Eun;Park, Shin-Hyung;Kim, Mi Young;Lee, Seoung-Jun;Moon, Soo-Ho;Ko, Byoung-Soo
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.241-247
    • /
    • 2018
  • Purpose: A hybrid-dynamic conformal arc therapy (HDCAT) technique consisting of a single half-rotated dynamic conformal arc beam and static field-in-field beams in two directions was designed and evaluated in terms of dosimetric benefits for radiotherapy of lung cancer. Materials and Methods: This planning study was performed in 20 lung cancer cases treated with the VERO system (BrainLAB AG, Feldkirchen, Germany). Dosimetric parameters of HDCAT plans were compared with those of three-dimensional conformal radiotherapy (3D-CRT) plans in terms of target volume coverage, dose conformity, and sparing of organs at risk. Results: HDCAT showed better dose conformity compared with 3D-CRT (conformity index: 0.74 ± 0.06 vs. 0.62 ± 0.06, p < 0.001). HDCAT significantly reduced the lung volume receiving more than 20 Gy (V20: 21.4% ± 8.2% vs. 24.5% ± 8.8%, p < 0.001; V30: 14.2% ± 6.1% vs. 15.1% ± 6.4%, p = 0.02; V40: 8.8% ± 3.9% vs. 10.3% ± 4.5%, p < 0.001; and V50: 5.7% ± 2.7% vs. 7.1% ± 3.2%, p < 0.001), V40 and V50 of the heart (V40: 5.2 ± 3.9 Gy vs. 7.6 ± 5.5 Gy, p < 0.001; V50: 1.8 ± 1.6 Gy vs. 3.1 ± 2.8 Gy, p = 0.001), and the maximum spinal cord dose (34.8 ± 9.4 Gy vs. 42.5 ± 7.8 Gy, p < 0.001) compared with 3D-CRT. Conclusions: HDCAT could achieve highly conformal target coverage and reduce the doses to critical organs such as the lung, heart, and spinal cord compared to 3D-CRT for the treatment of lung cancer patients.

Exocrine Pancreatic Secretion in Response to Electrical Stimulation of Dorsal Raphe Nucleus in Rats (흰쥐에서 배측 봉선핵의 전기자극이 췌장의 외분비기능에 미치는 영향)

  • Suh, Sang-Won;Park, Hyoung-Jin
    • The Korean Journal of Physiology
    • /
    • v.24 no.2
    • /
    • pp.403-411
    • /
    • 1990
  • The present investigation was performed to see a possible influence of the dorsal raphe nucleus (DRN) on pancreatic exocrine secretion in anesthetized rats since the DRN had been known to exert a regulatory mechanism on sympathetic activity which was known to be very important for pancreatic exocrine secretion, particularly in rats. Twenty-nine Sprague-Dawley rats fasted for 24 hours were anesthetized by i.p. injection of 1 g/kg of urethane. The pancreatic duct was cannulated to collect pancreatic juice while bile juice was diverted into the jejunum. The duodenopyloric junction was tightly ligated. After surgery for collection of pancreatic exocrine secretion and recording of carotid blood pressure, a coaxial electrode was stereotaxically inserted in the DRN with a guide of a brain atlas. And then, electrical stimulus of biphasic square wave with 2 v, 2 msec, 40 Hz was applied on the electrode for 10 minutes. Pancreatic volume flow and protein output secreted in 10 min were measured. Either bilateral cervical vagotomy or spinal cord transection at the level of $C4{\sim}C5$ was performed 20 min prior to stimulation of the DRN. 1) Electrical stimulation of the DRN resulted in significant (p<0.05) increase in pancreatic volume flow and protein output. These stimulatory effects were not affected by cervical vagotomy but completely abolished by cervical cord transection. 2) Electrical stimulation of the DRN also resulted in significant (p<0.05) rise of blood pressure of the carotid artery. The hypertensive effect was not affected by cervical vagotomy but completely abolished by cervical cord transection. The results strongly suggest that the DRN, a part of the central serotonergic system, could exert a stimulatory influence on pancreatic exocrine secretion by increasing the sympathetic activity in anesthetized rats.

  • PDF

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

An Improved FES System for Control of Paralyzed Upper Extremity

  • Ryoo, Young-Jae;Kim, Young-Min;Park, Chul-Soo;Park, Bong-Kee;Lim, Young-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.120-122
    • /
    • 1993
  • This paper describes an improved FES system to restore paralyzed extremities in spinal cord injury patients. For composing stimulus pattern which is suitable for each muscle, electrical stimulus pattern creating system is also developed by using IBM-PC. In the improved portable FES system using V40 microprocessor, muscle fatigue can be decreased by selecting the stimulus frequency which is proper to the response characteristics of each muscle. Driving softwares for the portable FES system and the stimulus pattern creating system are programmed with assembler and C language. A multichnnel portable FES system is designed to minimize the sire and weight using a D/A converter and 32 channel multiplexer.

  • PDF

Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC (비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가)

  • Lee, Sang-Bong;Park, Ki-Ju;Park, Du-Chan;Kim, Man-Wo;Kim, Jun-Gon;Noh, Sung-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.95-106
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the usefulness of an IMRT treatment plan according to whether there was a shell-type pseudo target during radiation therapy for patients in Stage III or IV of non-small cell lung cancer (NSCLC). Materials and Methods: After setting an IMRT (Intensity-Modulated Radiation Therapy, IMRT) plan for when there was a shell-type pseudo target (SPT) and when there was none (WSPT) with 22 patients in Stage III or IV of NSCLC, the investigator analyzed dose-volume histograms (DVHs) and made assessment with dosimetric comparisons such as homogeneity index (HI) inside the tumor target, conformity index (CI) of the tumor target, spinal cord maximum dose, Esophagus $V_{50%}$, mean lung dose (MLD), and $V_{40%}$, $V_{30%}$, $V_{20%}$, $V_{10%}$, $V_{5%}$. Results: The mean CI of WSPT and SPT was $1.22{\pm}0.04$ and $1.16{\pm}0.032$ ($.000^*$), respectively, and the mean HI of WSPT and SPT was $1.06{\pm}0.015$ and $1.07{\pm}0.014$ ($.000^*$), respectively. In SPT, the mean of each CI difference decreased by $-5.16{\pm}2.54%$, while HI increased by average $0.81{\pm}0.47%$. Esophagus $V_{50%}$ recorded $14.54{\pm}12.01%$ (WSPT) and $12.14{\pm}11.09%$ ($.000^*$, SPT) with the mean of SPT differences dropping by $-26.37{\pm}25.05%$. Mean spinal cord maximum dose was $3,898.44{\pm}1,075.0$ cGy (WSPT) and $3,810.8{\pm}1,134.9$ cGy ($.004^*$, SPT) with SPT dropping by average $-3.36{\pm}5.81%$. As for lung $V_{X%}$, the mean of $V_{5%}$ and $V_{10%}$ differences was $-1.62{\pm}2.29%$ ($.006^*$) and $-1.98{\pm}5.02%$ ($.005^*$), respectively with SPT making a decrease. The mean of V20%, V30%, and V40% differences was $-3.51{\pm}3.07%$ ($.000^*$), $-4.84{\pm}6.01%$ ($.000^*$), and $-6.16{\pm}8.46%$ ($.001^*$), respectively, with SPT making a decrease with statistical significance. In MLD assessment, SPT also dropped by average $-2.83{\pm}2.41%$ ($.000^*$). Those results show that SPT allows for mean 169 cGy (Max: 547 cGy, Min: 6.4 cGy) prescription dose. Conclusion: An IMRT treatment plan with SPT during radiation therapy for patients in Stage III or IV of NSCLC will help to reduce the risk of lung toxicity and radiation-induced pneumonia by cutting down radiation doses entering the normal lung, reduce the local control failure rate during radiation therapy due to increasing prescription doses to a certain degree, and increase treatment effects.

  • PDF

Physiological Responses to Maximal Exercise Loading in Spinal Cord Injured Paraplegia (척수손상으로 인한 하반신마비 환자의 최대운동부하시 생리학적 반응)

  • Yu, Byong-Kyu;Chung, Nak-Su
    • Physical Therapy Korea
    • /
    • v.6 no.2
    • /
    • pp.56-66
    • /
    • 1999
  • The purpose of this study focused how to show physiological responses comparing exercise group and non exercise group for progressive maximal wheelchair ergometer exercise loading in complete paraplegia. It also examined the various factors which would be influenced physiological responses. Sixteen subjects have been investigated in this study, and the subjects are divided into two groups as follows: 1) exercise group (7 subjects) 2) non exercise group (9 subjects). Each test was terminated by physical exhaustion and/or an inability to maintain a flywheel velocity. The results were as follows: 1) No difference was noted in pulmonary function test between two groups. 2) $\dot{v}$ Emax value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ Emax of exercise group was $69.67{\ell}/min$, non exercise group was $41.47{\ell}/min$. 3) $\dot{v}$ $O_2max$(${\ell}/min$) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$(${\ell}/min$) of exercise group was $1.72{\ell}/min$, non exercise group was $1.15{\ell}/min$. 4) $\dot{v}$ $O_2$ max(ml/kg/min) value during maximal exercise was significantly different between the groups (p<0.05). The mean $\dot{v}$ $O_2max$($ml/kg{\cdot}min$) of exercise group was $25.99ml/kg{\cdot}min$, non exercise group was $18.61{\ell}/min$. 5) Maximal heart rate(HRmax) value during maximal exercise was significantly different between the groups (p<0.05). The mean HRmax of exercise group was 180.43 beats/min, non exercise group was 175.00 beats/min. 6) $\dot{v}\;E/\dot{v}\;O_2$ value during maximal exercise was not significantly different between the groups (p>0.05). The mean $\dot{v}\;E/\dot{v}\;O_2$ of exercise group was $36.36{\ell}/{\ell}\;O_2$, non exercise group was $45.46{\ell}/{\ell}\;O_2$. Considering the results which explore the exercise group with paraplegia has shown the maximal aerobic power compared with non exercise group, regular and consistent physical training is highly assumed as a main factor to improve cardiopulmonary fitness.

  • PDF