• Title/Summary/Keyword: Spinal column

Search Result 84, Processing Time 0.034 seconds

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

Homeopathy - A Safe, Much Less Expensive, Non-Invasive, Viable Alternative for the Treatment of Patients Suffering from Loss of Lumbar Lordosis

  • Haque, Saiful;Das, Debarsi;Bhattacharya, Saugato;Sarkar, Tathagato;Khuda-Bukhsh, Anisur Rahman
    • Journal of Pharmacopuncture
    • /
    • v.19 no.4
    • /
    • pp.359-362
    • /
    • 2016
  • Objectives: Loss of lumbar lordosis causing pain and curvature of the vertebral skeleton to one side is a relatively uncommon disease. To our knowledge, successful treatment of loss of lumbar lordosis with any potentized homeopathic drug diluted above Avogadro's limit (that is, above a potency of 12C) has not been documented so far. In this communication, we intend to document a relatively rare case of loss of lumbar lordosis with osteophytic lippings, disc desiccation, and protrusion, causing a narrowing of secondary spinal canal and a bilateral neural foramina, leading to vertebral column curvature with acute pain in an adolescent boy. Methods: The patient had undergone treatment with orthodox Western medicines, but did not get any relief from, or cure of, the ailment; finally, surgery was recommended. The patient's family brought the patient to the Khuda-Bukhsh Homeopathic Benevolent Foundation where a charitable clinic is run every Friday with the active participation of four qualified homeopathic doctors. A holistic method of homeopathic treatment was adopted by taking into consideration all symptoms and selecting the proper remedy by consulting the homeopathic repertory, mainly of Kent. Results: The symptoms were effectively treated with different potencies of a single homeopathic drug, Calcarea phos. X-ray and magnetic resonance imaging (MRI) supported recovery and a change in the skeletal curvature that was accompanied by removal of pain and other acute symptoms of the ailment. Conclusion: Homeopathy can be a safe, much less expensive, non-invasive, and viable alternative for the treatment of such cases.

Posterior Thoracic Cage Interbody Fusion Offers Solid Bone Fusion with Sagittal Alignment Preservation for Decompression and Fusion Surgery in Lower Thoracic and Thoracolumbar Spine

  • Shin, Hong Kyung;Kim, Moinay;Oh, Sun Kyu;Choi, Il;Seo, Dong Kwang;Park, Jin Hoon;Roh, Sung Woo;Jeon, Sang Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.922-932
    • /
    • 2021
  • Objective : It is challenging to make solid fusion by posterior screw fixation and laminectomy with posterolateral fusion (PLF) in thoracic and thoracolumbar (TL) diseases. In this study, we report our experience and follow-up results with a new surgical technique entitled posterior thoracic cage interbody fusion (PTCIF) for thoracic and TL spine in comparison with conventional PLF. Methods : After institutional review board approval, a total of 57 patients who underwent PTCIF (n=30) and conventional PLF (n=27) for decompression and fusion in thoracic and TL spine between 2004 and 2019 were analyzed. Clinical outcomes and radiological parameters, including bone fusion, regional Cobb angle, and proximal junctional Cobb angle, were evaluated. Results : In PTCIF and conventional PLF, the mean age was 61.2 and 58.2 years (p=0.46), and the numbers of levels fused were 2.8 and 3.1 (p=0.46), respectively. Every patient showed functional improvement except one case of PTCIF. Postoperative hematoma as a perioperative complication occurred in one and three cases, respectively. The mean difference in the regional Cobb angle immediately after surgery compared with that of the last follow-up was 1.4° in PTCIF and 7.6° in conventional PLF (p=0.003), respectively. The mean durations of postoperative follow-up were 35.6 months in PTCIF and 37.3 months in conventional PLF (p=0.86). Conclusion : PTCIF is an effective fusion method in decompression and fixation surgery with good clinical outcomes for various spinal diseases in the thoracic and TL spine. It provides more stable bone fusion than conventional PLF by anterior column support.

Retroperitoneal Extrapleural Approach for Corpectomy of the First Lumbar Vertebra : Technique and Outcome

  • Zidan, Ihab;Khedr, Wael;Fayed, Ahmed Abdelaziz;Farhoud, Ahmed
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.61-70
    • /
    • 2019
  • Objective : Corpectomy of the first lumbar vertebra (L1) for the management of different L1 pathologies can be performed using either an anterior or posterior approach. The aim of this study was to evaluate the usefulness of a retroperitoneal extrapleural approach through the twelfth rib for performing L1 corpectomy. Methods : Thirty consecutive patients underwent L1 corpectomy between 2010 and 2016. The retroperitoneal extrapleural approach through the 12th rib was used in all cases to perform single-stage anterior L1 corpectomy, reconstruction and anterior instrumentation, except for in two recurrent cases in which posterior fixation was added. Visual analogue scale (VAS) was used for pain intensity measurement and ASIA impairment scale for neurological assessment. The mean follow-up period was 14.5 months. Results : The sample included 18 males and 12 females, and the mean age was 40.3 years. Twenty patients (67%) had sensory or motor deficits before the surgery. The pathologies encountered included traumatic fracture in 12 cases, osteoporotic fracture in four cases, tumor in eight cases and spinal infection in the remaining six cases. The surgeries were performed from the left side, except in two cases. There was significant improvement of back pain and radicular pain as recorded by VAS. One patient exhibited postoperative neurological deterioration due to bone graft dislodgement. All patients with deficits at least partially improved after the surgery. During the follow-up, no hardware failures or losses of correction were detected. Conclusion : The retroperitoneal extrapleural approach through the 12th rib is a feasible approach for L1 corpectomy that can combine adequate decompression of the dural sac with effective biomechanical restoration of the compromised anterior loadbearing column. It is associated with less pulmonary complication, no need for chest tube, no abdominal distention and rapid recovery compared with other approaches.

Evaluation of the accuracy of mobile cone-beam computed tomography after spinal instrumentation surgery

  • Eom, Ki Seong;Park, Eun Sung;Kim, Dae Won;Park, Jong Tae;Yoon, Kwon-Ha
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.12-18
    • /
    • 2022
  • Purpose: Pedicle screw fixation provides 3-column stabilization, multidimensional control, and a higher rate of interbody fusion. Although computed tomography (CT) is recommended for the postoperative assessment of pedicle screw fixation, its use is limited due to the radiation exposure dose. The purpose of this preliminary retrospective study was to assess the clinical usefulness of low-dose mobile cone-beam CT (CBCT) for the postoperative evaluation of pedicle screw fixation. Methods: The author retrospectively reviewed postoperative mobile CBCT images of 15 patients who underwent posterior pedicle screw fixation for spinal disease from November 2019 to April 2020. Pedicle screw placement was assessed for breaches of the bony structures. The breaches were graded based on the Heary classification. Results: The patients included 11 men and four women, and their mean age was 66±12 years. Of the 122 pedicle screws, 34 (27.9%) were inserted in the thoracic segment (from T7 to T12), 82 (67.2%) in the lumbar segment (from L1 to L5), and six (4.9%) in the first sacral segment. Although there were metal-related artifacts, the image of the screw position (according to Heary classification) after surgery could be assessed using mobile CBCT at all levels (T7-S1). Conclusions: Mobile CBCT was accurate in determining the location and integrity of the pedicle screw and identifying the surrounding bony structures. In the postoperative setting, mobile CBCT can be used as a primary modality for assessing the accuracy of pedicle screw fixation and detecting postoperative complications.

Analysis of the Risk Factors for Unfavorable Radiologic Outcomes after Fusion Surgery in Thoracolumbar Burst Fracture : What Amount of Postoperative Thoracolumbar Kyphosis Correction is Reasonable?

  • Seo, Dong Kwang;Kim, Chung Hwan;Jung, Sang Ku;Kim, Moon Kyu;Choi, Soo Jung;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.96-105
    • /
    • 2019
  • Objective : The aims in the management of thoracolumbar spinal fractures are not only to restore vertebral column stability, but also to obtain acceptable alignment of the thoracolumbar junction (T-L junction) to prevent complications. However, insufficient surgical correction of the thoracolumbar spine would be likely to cause late progression of abnormal kyphosis. Therefore, we identified the surgical factors that affected unfavorable radiologic outcomes of the thoracolumbar spine after surgery. Methods : This study was conducted in a single institution from January 2007 to December 2013. A total of 98 patients with unstable thoracolumbar spine fracture were included. In these patients, fixation was done through transpedicular screws with rods by three surgical patterns. We reviewed digital radiographs and analyzed the images preoperatively and postoperatively during follow-up visits to compare the change of the thoracolumbar Cobb angle with radiologic parameters and clinical outcomes. The unfavorable radiologic group was defined as the patients who were measured as having greater than 20 degrees of thoracolumbar Cobb angle on the last follow-up, or who underwent kyphotic progression of thoracolumbar Cobb angle greater than 10 degrees from the immediate postoperative state to final follow-up, or who had overt instrument failure with/without additional surgery. We assessed the risk factors that affected the unfavorable radiologic outcomes. Results : We had 43 patients with unfavorable radiologic outcomes, including 35 abnormal thoracolumbar alignments and 14 instrumental failures with/without additional surgery. The multivariate logistic regression test showed that immediate postoperative T-L junction Cobb angle less than 10.5 degrees was a statistically significant risk factor, as well as the presence of osteoporosis (p=0.017 and 0.049, respectively). Conclusion : Insufficient correction of thoracolumbar kyphosis was considered to be a major factor of an unfavorable radiological outcome. The spinal surgeon should consider that having a T-L junction Cobb angle larger than 10.5 degrees immediately after surgery could result in an unfavorable radiological outcome, which is related to a poor clinical outcome.

Dual control of the vestibulosympathetic reflex following hypotension in rats

  • Park, Sang Eon;Jin, Yuan-Zhe;Park, Byung Rim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.6
    • /
    • pp.675-686
    • /
    • 2017
  • Orthostatic hypotension (OH) is associated with symptoms including headache, dizziness, and syncope. The incidence of OH increases with age. Attenuation of the vestibulosympathetic reflex (VSR) is also associated with an increased incidence of OH. In order to understand the pathophysiology of OH, we investigated the physiological characteristics of the VSR in the disorder. We applied sodium nitroprusside (SNP) to conscious rats with sinoaortic denervation in order to induce hypotension. Expression of pERK in the intermediolateral cell column (IMC) of the T4~7 thoracic spinal regions, blood epinephrine levels, and blood pressure were evaluated following the administration of glutamate and/or SNP. SNP-induced hypotension led to increased pERK expression in the medial vestibular nucleus (MVN), rostral ventrolateral medullary nucleus (RVLM) and the IMC, as well as increased blood epinephrine levels. We co-administered either a glutamate receptor agonist or a glutamate receptor antagonist to the MVN or the RVLM. The administration of the glutamate receptor agonists, AMPA or NMDA, to the MVN or RVLM led to elevated blood pressure, increased pERK expression in the IMC, and increased blood epinephrine levels. Administration of the glutamate receptor antagonists, CNQX or MK801, to the MVN or RVLM attenuated the increased pERK expression and blood epinephrine levels caused by SNP-induced hypotension. These results suggest that two components of the pathway which maintains blood pressure are involved in the VSR induced by SNP. These are the neurogenic control of blood pressure via the RVLM and the humoral control of blood pressure via epinephrine release from the adrenal medulla.

Distribution and Excretion of Radioactivity Following Intraportal Administration of $^{166}$ 7Ho-Chitosan Complex to Rats (흰쥐의 간문맥으로 투여한 $_{166}$ Holmium-chitosan의 분포와 배설)

  • BAEK, Min Sun;PARK, Kyung Bae;KIM, Dong Hyun
    • Biomolecules & Therapeutics
    • /
    • v.5 no.3
    • /
    • pp.233-238
    • /
    • 1997
  • The distribution and excretion of radioactivity were examined after intraportal administration of sup 166/Ho-chitosan complex at a dose of 1 mcitg (10 mg chitosan/kg) to rats. Whole body macroautoluminographs showed that the radioactivity after an administration was concentrated in liver and perfused primarily to organs including kidney, spleen, and bone marrow, then to muscle and brain. Similar profiles were observed from 2 hr to 168 hr after the administration. The relative percentage of radioactivity in bone and spinal column increased with time, suggesting that free $^{166}$ Ho, released from chitosan complex deposited in the liver, selectively binds to these tissues. $^{166}$ Ho-chitosan complex administered intraportally was excreted less than 4% through urine (2.7$\pm$0.8%) and feces (0.65 $\pm$ 0.4%) up to seven days. These results demonstrate that the radio-activity of $_{166}$ Ho-chitusan complex when administered intraportally, mainly localizes in liver without affec-ting other tissues and organs. Considering the short half life of $^{166}$ Ho and the localization to the liver, $^{166}$ Ho-chitosan complex might be a useful agent in the treatment of hepatic carcinoma.

  • PDF

Development of a Special Program for Automatic Generation of Scoliotic Spine FE Model with a Normal Spine Model (정상 척추체 모델을 이용한 척추측만증 모델 자동 생성 프로그램 개발)

  • Ryu Han-Kyu;Kim Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.187-194
    • /
    • 2006
  • Unexpected postoperative changes, such as growth in rib hump and shoulder unbalance, have been occasionally reported after corrective surgery for scoliosis. However there has been neither experimental data fer explanation of these changes, nor the suggestion of optimal correction method. Therefore, the numerical study was designed to investigate the post-operative changes of vertebral rotation and rib cage deformation after the corrective surgery of scoliosis. A mathematical finite element model of normal spine including rib cage, sternum, both clavicles, and pelvis was developed with anatomical details. In this study, we also developed a special program which could convert a normal spine model to a desired scoliotic spine model automatically. A personalized skeletal deformity of scoliosis model was reconstructed with X-ray images of a scoliosis patient from the normal spine structures and rib cage model. The geometric mapping was performed by translating and rotating the spinal column with an amount analyzed from the digitized 12 built-in coordinate axes in each vertebral image. By utilizing this program, problems generated in mapping procedure such as facet joint overlapping, vertebral body deformity could be automatically resolved.

Radicular Pain due to Subsidence of the Nitinol Shape Memory Loop for Stabilization after Lumbar Decompressive Laminectomy

  • Son, Byung-Chul;Kim, Deog-Ryeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.61-64
    • /
    • 2015
  • A number of dynamic stabilization systems have been used to overcome the problems associated with spinal fusion with rigid fixation recently and the demand for an ideal dynamic stabilization system is greater for younger patients with multisegment disc degeneration. Nitinol, a shape memory alloy of nickel and titanium, is flexible at low temperatures and regains its original shape when heated, and the Nitinol shape memory loop (SML) implant has been used as a posterior tension band mostly in decompressive laminectomy cases because the Nitinol implant has various characteristics such as high elasticity and a tensile force, flexibility, and biological compatibility. The reported short-term outcomes of the application of SMLs as posterior column supporters in cervical and lumbar decompressive laminectomies seem to be positive, and complications are minimal except for the rare occurrence of pullout and fracture of the SML. However, there was no report of neurological complications related to neural compression in spite of the use of the loop of SML in the epidural space. The authors report a case of delayed development of radiating pain caused by subsidence of the SML resulting epidural compression.