• Title/Summary/Keyword: Spherical power

Search Result 307, Processing Time 0.031 seconds

Analysis on Ocular Components Variation with the Difference of Both Refractive Errors (양안 굴절이상 차이에 의한 안광학상수 변화도 분석)

  • Lee, Hae-Jung;Lee, Eun-Hee;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.14 no.11
    • /
    • pp.435-440
    • /
    • 2016
  • The aim of study was to provide the preliminary data to find out characteristics of the difference between both refractive errors through analysis of ocular components variation. We measured spherical equivalent power and corneal radius with KR-8800, and axial length and anterior chamber depth with IOL Master, and the difference of measuring values between the right eye and left eye was applied as the absolute values in 100 adults aged 20~59 years. In all participants, the most common results showed that spherical equivalent power was $-1.83{\pm}2.17D$, axial length was 23.00~24.99mm, corneal radius was 7.50~7.89mm, and anterior chamber depth was 3.60~4.09mm. There are significant correlations between both eyes in axial length and anterior chamber depth with the difference of both spherical equivalent power. The difference of both axial lengths was the biggest with the difference of both refractive errors, and shown the highest correlation. The convergence complex study through classification by aspects is needed since the difference of both refractive errors is closely related with ocular components variation, and poor visual function would be caused by the difference of both refractive errors.

Thoracic Outlet Syndrome: The Effects of Scalenus Stretching Exercise (흉곽출구증후군: 사각근 신장운동의 효과)

  • Lee, Mun-Hwan
    • Physical Therapy Korea
    • /
    • v.13 no.2
    • /
    • pp.43-51
    • /
    • 2006
  • The term thoracic outlet syndrome (TOS) is used to describe patients with compressed subclavian arteries, veins, and brachial plexuses in the region of the thoracic outlet. The objective of this study was to evaluate a scalenus stretching exercise that aims to restore normal function to patients with TOS. This study consisted of 60 patients with symptoms of TOS, and divided the patients into 3 groups: one that received manual therapy, one that practiced self stretching, and a control group. Each group consisted of 20 patients. This study assessed the efficacy of scalenus stretching exercise by examining the resting pain, tenderness, spherical grip power, and pinch grip power of patients. The data were analyzed using one-way ANOVA, Scheffe post hoc test, and independent t-test. The results showed that resting pain was statistically significant within the manual therapy and self stretching groups (p<.05), and that the resting pain of the manual therapy group was more statistically significant than that of the self stretching group (p<.05). Tenderness, spherical grip power, and pinch grip were statistically significant within the manual therapy and self stretching groups (p<.05), but there was no statistically significant difference between the two groups (p>.05). Finally I could see that there were no statistical differences between manual therapy and self stretching to improve the symptoms of the patients with TOS. These results imply that self stretching by patients is as important as manual therapy by a physical therapist.

  • PDF

Preparation and Luminescence Properties of Spherical Sr4Al14O25:Eu2+ Phosphor Particles by a Liquid Synthesis (액상법을 이용한 구상의 Sr4Al14O25:Eu2+ 형광체의 합성 및 발광 특성)

  • Lee, Jeong;Choi, Sungho;Nahm, Sahn;Jung, Ha-Kyun
    • Korean Journal of Materials Research
    • /
    • v.24 no.7
    • /
    • pp.351-356
    • /
    • 2014
  • A spherical $Sr_4Al_{14}O_{25}:Eu^{2+}$ phosphor for use in white-light-emitting diodes was synthesized using a liquid-state reaction with two precipitation stages. For the formation of phosphor from a precursor, the calcination temperature was $1,100^{\circ}C$. The particle morphology of the phosphor was changed by controlling the processing conditions. The synthesized phosphor particles were spherical with a narrow size-distribution and had mono-dispersity. Upon excitation at 395 nm, the phosphor exhibited an emission band centered at 497 nm, corresponding to the $4f^65d{\rightarrow}4f^7$ electronic transitions of $Eu^{2+}$. The critical quenching-concentration of $Eu^{2+}$ in the synthesized $Sr_4Al_{14}O_{25}:Eu^{2+}$ phosphor was 5 mol%. A phosphor-converted LED was fabricated by the combination of the optimized spherical phosphor and a near-UV 390 nm LED chip. When this pc-LED was operated under various forward-bias currents at room temperature, the pc-LED exhibited a bright blue-green emission band, and high color-stability against changes in input power. Accordingly, the prepared spherical phosphor appears to be an excellent candidate for white LED applications.

Spherical Slepian Harmonic Expression of the Crustal Magnetic Vector and Its Gradient Components (구면 스레피안 함수로 표현된 지각 자기이상값과 구배 성분)

  • Kim, Hyung Rae
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.269-280
    • /
    • 2016
  • I presented three vector crustal magnetic anomaly components and six gradients by using spherical Slepian functions over the cap area of $20^{\circ}$ of radius centered on the South Pole. The Swarm mission, launched by European Space Agency(ESA) in November of 2013, was planned to put three satellites into the low-Earth orbits, two in parallel in East-West direction and one in cross-over of the higher altitude. This orbit configuration will make the gradient measurements possible in North-South direction, vertical direction, as well as E-W direction. The gravity satellites, such as GRACE and GOCE, have already implemented their gradient measurements for recovering the accurate gravity of the Earth and its temporal variation due to mass changes on the subsurface. However, the magnetic gradients have little been applied since Swarm launched. A localized magnetic modeling method is useful in taking an account for a region where data availability was limited or of interest was special. In particular, computation to get the localized solutions is much more efficient and it has an advantage of presenting high frequency anomaly features with numbers of solutions fewer than the global ones. Besides, these localized basis functions that were done by a linear transformation of the spherical harmonic functions, are orthogonal so that they can be used for power spectrum analysis by transforming the global spherical harmonic coefficients. I anticipate in scientific and technical progress in the localized modeling with the gradient measurements from Swarm and here will do discussion on the results of the localized solution to represent the three vector and six gradient anomalies over the Antarctic area from the synthetic data derived from a global solution of the spherical harmonics for the crustal magnetic anomalies of Swarm measurements.

Study of a Photovoltaic System as an Emergency Power Supply for Offshore Plant Facilities (해양플랜트 설비의 비상전원공급을 위한 태양광 발전시스템 연구)

  • Choi, Gun Hwan;Lee, Byung Ho;Jung, Rho-Taek;Shin, Kyubo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.279-286
    • /
    • 2018
  • The use of eco-friendly energy in the offshore plant system is expanding because conventional generators are operated by fossil fuel or natural gas. Eco-friendly energy, which replaces existing power generation methods, should be capable of generating the power for lighting protection equipment, airborne fault indication, parameter measurement, and others. Most of the eco-friendly energy used in offshore plant facilities is solar and wind power. In the case of using photovoltaic power, because the structure must be constructed based as flat solar panels, it can be damaged easily by the wind. Therefore, there is a need for a new generation system composed of a spherical structure that does not require a separate structure and is less influenced by the wind. Considering these characteristics, in this study we designed, fabricated, and tested a unit that could provide the most efficient spherical photovoltaic power generation considering wind direction and wind pressure. Our test results indicated that the proposed system reduced costs because it did not require any separate structure, used eco-friendly energy, reduced carbon dioxide emissions, and expanded the proportion of eco-friendly energy use by offshore plant facilities.

Survey on the Refractive Errors Status in the First Wearing Glasses (최초 안경착용시의 굴절이상 상태 조사)

  • Kim, Hye-Ran;Jang, Seong-Ju;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: This study is to survey that uncomfortable feeling of visual acuity in the first wearing glasses, the number of visiting in age, above vision ranging and refractive errors, astigmatism, and anisometropia. Methods: Automatic refraction and naked visual acuity test executed to receive prescription glasses that the man 509 and women's 499 people visited for the first time, among 3~15 years old who visited an ophthalmoiogical hospital, from January to December, 2003. Results: The first wearing glasses started 3 years old and the most cases was 8~9 years old when they were visited visual acuity 0.5 to 0.7 in most cases. Refractive errors appeared 8 years old and its most plentifully with 20.4%, 92.2% was myopia and 5.2% was hyperopia for the man. Also cases of women was 91.9% for myopia and 5.1% for the hyperopia. Spherical equivalent power was S-1.50${\pm}$1.10D and appeared 62.3% for the low myopia. Astigmatism was appeared 44.6% for the with the rule astigmatism and 75% was cylinder power lower than 1.00D. Cases of simple astigmatism need to glass when was cylinder power C-1.37${\pm}$1.01D, and C-0.50D appeared most distribution. More than 2.00D anisometropia appeared 2.3% for the whole subjective. Conclusions: Of the first wearing glasses visual acuity is 0.5~0.7, spherical equivalent power is S-1.50${\pm}$1.10D, cylinder power of simple astigmatism is C-1.37${\pm}$1.01D.

  • PDF

Comparison of the Refracting Power and Aberration according to the Measurement Change in Illumination and Area of the Pupils (조도와 동공 영역의 측정 변화에 따른 굴절력과 수차의 비교)

  • Kim, Bong-Hwan;Han, Seon-Hee;Park, Byeong-Gyu;Hwang, Hyeon-Ju;Bae, Ye-Sol;Seo, Jeong-Bin;Yeo, Ye-Eun;Yoon, Min-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.2
    • /
    • pp.550-555
    • /
    • 2016
  • Purpose. We compared with the refracting power and aberration according to the measurement change in illumination and the pupils area by using the auto refraction instruments. Methods. In this study it were examined 64 eyes without eye disease, 21.4 (${\pm}2.54$) age, 32 (male 10, female 22) patients. Experiments in general illumination using the auto refraction instruments (HRK-8000A, Huvitz, Korea) was measured in both eyes 3 times and after scotopic for 30 minutes in a dark room blocked the light was measured in the same way. Aberration were measured coma, spherical aberration, high and low order aberrations in a general illumination (3500 lux) and low illumination (5 lux) of the pupil area 3.96 mm and 5.96 mm. Results. In the general illumination for measuring of the pupil area, the refractive power, coma, spherical aberration and low order aberration was no significant difference. In the low illumination, spherical aberration of the pupil area was $0.005({\pm}0.015){\mu}m$ in a 3.96mm, $0.014({\pm}0.020){\mu}m$ in a 5.96 mm and appeared a significant difference(p = 0.003). In general and low illumination on the results of comparing the measured values of the refractive power and aberration at the pupil area 3.96 mm, high order aberrations was $0.205({\pm}0.145){\mu}m$ in general illumination, $0.132({\pm}0.075){\mu}m$ in low illumination and appeared a significant differences(p = 0.001). High order aberrations at the pupil area 5.96 mm was $0.278({\pm}0.244){\mu}m$ in general illumination, $0.150({\pm}0.092){\mu}m$ in low illumination and appeared a significant differences(p = 0.000). Conclusions. When the eye refractive power measured by the automatic refraction does not depend on the illumination conditions and size of the observation pupil area, it was found that aberrations are affected by the illumination and the observation pupil area. It was found that the eye examination chamber illumination to obtain accurate measurement produces better results to decrease than to increase.

A Study of Eye Refraction State on Male Old Age (노인 남성의 안굴절 상태에 대한 연구)

  • Yoo, Jae Tae;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.21-25
    • /
    • 2000
  • The old age may experienced the visual acuity decrease according to refraction abnormality and they have a inconvenient real life style on viewing condition. So that, This study can provide the accurate information on the treatment of visual acuity of a male old ages by test of eye refraction state. The test was performed the visual acuity test by the object and subject methods.and the subjects was the Korean male over 55 old age. The eye types were 0.8 % positive for emmetropia, 15.2 % for myopia, and 84 % for hyperopia, respectively. The abnormal refraction eyes were 1.3 % positive for simple myopic astigmatism, 13.9 % for compound myopic astigmatism. 3.4 % for simple hyperopia and 3.1 % for simple hyperopic astigmatism, 77.5 % for mixed astigmatism, respectively. The asix of astigmatisms were 62% positive for against-the-rule astigmatism, 6% for with-the rule astigmatism, and 32 % for oblique astigmatism, respectively. On the total myopic spherical power, the $-0.50{\leq}$spheric equivalent <-2.00 diopter was 84.3%, the $-2.00{\leq}$spherical equivalent <-6.00.diopter was 15.7%. On the total hyperopic spherical power, the $+0.50{\leq}$spheric equivalent <+2.00 diopter was 74.2%, the $+2.00{\leq}$spherical equivalent <+6.00 diopter was 24.8%, and anything over the +6.00 diopter was 1%. On the astigmatic power, the $0.5{\leq}$cylinder <1.00 diopter was 54.1%, the $1.00{\leq}$cylinder <2.00 diopter was 32.4%, and anything over the 2.00 cylinder diopter was 13.5%.

  • PDF

Comparative Analysis of Refractive Power on Trial Case Lenses (검안렌즈의 굴절력 비교 분석)

  • Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.321-334
    • /
    • 2012
  • Purpose: In this study, the distribution and differences in refractive powers on trial case lenses were investigated. Methods: We measured refractive powers at optical center and periphery using 4 trial case lens sets. According to international standards, the distribution and uniformity in refractive powers were investigated. Results: The lens shapes were different in different kinds of trial case lenses and some of lenses were out of tolerance according international standards. In some cases, the power differences were found between front and back side as well as between optical center and peripheral regions and also the cylindrical power on spherical lens and spherical power on the cylindrical lens were measured. Conclusions: Trial case lens are used to assess the refractive error, therefore, more precise control of the manufacturing process for trial case lenses and more thorough quality control will be required to offer an accurate vision test. More careful attention in using trial case lens is also required.

Optical constant of the reduced eye based on theoretical finite model eye (이론적 정밀모형안에 기초한 환산모형안의 광학상수)

  • 김상기
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.268-273
    • /
    • 2004
  • A finite model eye based on longitudinal spherical aberration is designed by an optimization method. Longitudinal spherical aberration for pupil diameter between 1 mm and 8 mm is graphed theoretically and compared with other model eyes. The chromatic dispersions are adjusted to fit experimentally observed chromatic aberration of the eye. This is a finite model eye with four a spheric refracting surfaces. It has an effective focal length of 15.842 mm. A designed reduced eye has an equivalent power of 63.12 Diopter, curvature radius of 5.281 mm, index of 1.33333, and axial length of 21.123 mm.