• Title/Summary/Keyword: Spherical power

Search Result 307, Processing Time 0.021 seconds

ANALYTICAL AND NUMERICAL SOLUTIONS OF A CLASS OF GENERALISED LANE-EMDEN EQUATIONS

  • RICHARD OLU, AWONUSIKA;PETER OLUWAFEMI, OLATUNJI
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.26 no.4
    • /
    • pp.185-223
    • /
    • 2022
  • The classical equation of Jonathan Homer Lane and Robert Emden, a nonlinear second-order ordinary differential equation, models the isothermal spherical clouded gases under the influence of the mutual attractive interaction between the gases' molecules. In this paper, the Adomian decomposition method (ADM) is presented to obtain highly accurate and reliable analytical solutions of a class of generalised Lane-Emden equations with strong nonlinearities. The nonlinear term f(y(x)) of the proposed problem is given by the integer powers of a continuous real-valued function h(y(x)), that is, f(y(x)) = hm(y(x)), for integer m ≥ 0, real x > 0. In the end, numerical comparisons are presented between the analytical results obtained using the ADM and numerical solutions using the eighth-order nested second derivative two-step Runge-Kutta method (NSDTSRKM) to illustrate the reliability, accuracy, effectiveness and convenience of the proposed methods. The special cases h(y) = sin y(x), cos y(x); h(y) = sinh y(x), cosh y(x) are considered explicitly using both methods. Interestingly, in each of these methods, a unified result is presented for an integer power of any continuous real-valued function - compared with the case by case computations for the nonlinear functions f(y). The results presented in this paper are a generalisation of several published results. Several examples are given to illustrate the proposed methods. Tables of expansion coefficients of the series solutions of some special Lane-Emden type equations are presented. Comparisons of the two results indicate that both methods are reliably and accurately efficient in solving a class of singular strongly nonlinear ordinary differential equations.

Changes in Accommodative Function of Young Adults in their Twenties following Smartphone Use (스마트폰 사용에 따른 20대 성인의 조절기능 변화)

  • Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.

A Study of Eye Refractive Error for High School Students in Tong-Du-Cheon Area ;(II) (동두천지역 고등학생의 안굴절상태 조사 및 연구 II)

  • Choi, Hae Jung;Cha, Jung Won;Park, Moon Chan;Chen, Ko Hsein
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.103-113
    • /
    • 1998
  • Until now, the study of eye refractive error examination for high school students are a few report that in Korea. In particular, there is few report about the visual power for same group during several years. We compared the study of refractive error done this year with that reported three years ago at the same high school. From the these data, the distribution of ammetropia was investigated. The study of refractive error for high school students was also compared with those reported before for the Adults and the middle school student. When the visual power is refered to spherical equivalent, the 36% of the whole students examined above had emmetropia and the other part of them fumed out to be ammetropia which is classify to 60.6% belonged to myopia and 4.4% belonged to hyperpia. The ratio of myopia for this year students is increased in comparision with the students in 1995. The ratio of emmetropia for this year students is 7.4% higher, and the ratio of myopia for this year students is 4% higher, but the ratio of hyperopia is very lower than that for the adults in 1997. In the kind of refractive error, it is classified that a simple myopia is shown to highest ratio as a 28.6% of 1212 eyes examined, a compound myopic astigmatism to the next high ratio as a 22.4%, a simple myopic astigmatism as 14.4%, a simple hyperopic astigmatism as 3.1%, a mixed astigmatism as a 1.7%, a simple astigmatism as 1.2%, a compound hyperopic astigmatism as 1.2%, respectively. The percentage of an astigmatism is a 76.7% of total eyes examined if Cyl-0.25 Dptr is included to an astigmatism. On the other hand, The percentage of an astigmatism is a 45.6% of total eyes examined if Cyl-0.25 Dptr is excluded to an astigmatism. In the kind of astigmatism, the number of students had an astigmatism with the rule is about 4.5 times than that of astigmatism against the rule. From the result of comparision the right eye with the left eye, the right eye of the students had more a myopic refractive error than the left eye, which is same as adults' case, there is no difference in a refractive error between the boy students and the girl students.

  • PDF

Manufacturing of Artificial Lightweight Aggregates using a Coal Fly Ash Discharged from Fluidized Bed Combustor (유동층(流動層) 연소기(撚燒器)로 부터 발생(發生)된 석탄(石炭) 비산(飛散)재를 이용(利用)한 인공경량골재(人工輕量骨材) 제조(製造))

  • Kang, Min-A;Kang, Seung-Gu
    • Resources Recycling
    • /
    • v.20 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • The spherical artificial aggregates (AAs) with a diameter of 8 mm, which contains fly ashes discharged from the fluidized bed combustion in a thermal power plant and clay were manufactured by direct sintering method at $1050{\sim}1250^{\circ}C$ for 10 minutes. The effect of fly ash contents on the bloating phenomenon in the AAs was analyzed. The AAs containing fly ash of the amount under 50 wt% showed the black-coring and bloating phenomena. The AAs containing fly ash of the amount over 5Owt%, however, the specific gravity was increased and the color of specimens fully changed to black. These color change phenomena were caused from the formation of FeO by the reduction reaction of almost $Fe_2O_3$ component by the excessive reducing atmosphere formed simultaneously with the rapid emission of the gases generated from the high contents of unburned carbon of with increasing the added fly ash amount. Specific gravity was decreased as fly ash contents increased in the case of sintering at the same temperature condition. Water absorption of all specimens except of the specimens containing 10 wt% fly ashes decreased with increasing sintering temperature. These were because a liquid phase was formed as the increasing the sintering temperature. In the case of the specimens manufactured in this study containing fly ashes discharged from the fluidized bed combustor in a the thermal power plant and 10~90 wt% of clay, the specific gravity was 0.9~1.8 and the water absorptivity was 8~60%, therefore it is considered that those results can be applied to the light or heavy aggregates.

Comparison of Stereopsis by Influence Factors in Induced Aniseikonia (유발 부등상시에서 영향인자에 따른 입체시의 비교)

  • Jung, Su A;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.465-471
    • /
    • 2013
  • Purpose: This study was conducted to research effects of influence factors on stereopsis of induced aniseikonia in emmetropia. Methods: 20 college students (a mean age of $22.50{\pm}2.72$ years, 14 males, 6 females) were selected as subjects and all of them had no ocular disease or systemic disease, the refractive correction of spherical equivalent within ${\pm}0.50$ D, the corrected visual acuity of 1.0 or better and the aniseikonia values less than 1% by AWAYA. Subject's dominant eye was checked by Hole in card method and contact lenses of -7.00 ~ +7.00D were fitted to cause anisometropia in dominant eye or non-dominant eye, respectively. And then aniseikonia was induced with spectacles to correct refractive error by contact lenses. Stereopsis was measured by Random Dot Stereo Acuity Test with LEA symbols$^{(R)}$ (Vision Assessment Corporation$^{TM}$, USA). Results: Stereopsis was remarkably reduced by inducing aniseikonia, with induced aniseikonia in dominant eye, with higher diopter of wearing contact lenses to induce anisometropia, with spectacles lenses correction of minus power after fitting contact lenses with plus power and in case of men. Conclusions: It should be considered to correct anisometropia that aniseikonia could cause reduction of stereopsis.

Clinical Evaluation of Prism-stabilized Toric Soft Contact Lens Fit (프리즘 안정화 디자인 토릭 소프트 콘택트렌즈 피팅에 대한 임상 평가)

  • Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • Purpose: This study was to evaluate the clinical performance of 1-Day disposable toric soft contact lenses (TSCL) and to compare the visual performance with glasses and TSCL. Methods: In a two-week investigation of 'prism ballast' designed TSCL, occular refractions in 15 (30 eyes) healthy subjects were within the range of -2.75 D TO -8.00 D spherical power and -0.75 DC to -2.25 DC cylinderical power (with-the-rule). Subjects were assessed the clinical performance (orientation, centration, movement, tightness, rotation recovery, symptoms) of TSCL and compared binocular vision and contrast sensitivity with corrected glasses and TSCL at initial and two-week follow-up visits. Results: The prism-ballast design TSCL achieved better orientation, rotation recovery and symptoms over 2 week period. There was no statistically significant difference between spectacles and TSCL with respect to measuring binocular vision and contrast sensitivity. Conclusions: The clinical performance was good with prism-ballast design toric soft contact lenses. Evaluation of binocular vision and contrast sensitivity did not show the differences between spectacles and TSCL correction. This study suggests that TSCL wearers can be achieved similar visual performance for spectacles wearers.

Properties of Carbon-Rich Particles and Purified Ash Obtained from Countercurrent Column Flotation (부유분리법에 의해 분리한 고순도 정제석탄회와 고탄소 석탄회의 특성)

  • 이정언;안영철;김성찬;구재현;나성수;신진혁;이재근
    • Resources Recycling
    • /
    • v.8 no.4
    • /
    • pp.11-19
    • /
    • 1999
  • Fly ash generated from (he pulverized coal power plant have caused the serious ocean pollution due to the disposal in the ash pond, the life reduction of a power plant and the waste of re-utilizable resource The research to reuse the unburned carbon and mineral composing of the ash has been progressed. In this study. the physical and chemical characteristics of high grade ash and unburned carbon particles obtained from countercurrent column flotation are investigated. The cleaned ash of the less 0,5% loss on Ignition(LOI) in carbon content is a spherical sphere and 39.8${\mu}m$ in size of MMD(Mass Median Diameter). 2.22 $m^2/g$ of specific area. The morphology of high LOI carbon particles is a amorphousness, 76.6 ${\mu}m$ of particle size and 15.2 $m^2/g$ of specific The high grade cleaned ash and the high LOI ash have some difference in the light of physical. chemical and morphological characteristics

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF

Effect on Myopia Progression Wearing Eye-glasses for School Children (학령기 아동의 안경착용이 근시진행에 미치는 영향)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.195-200
    • /
    • 2011
  • Purpose: We analyzed the influence of myopic's eye-glasses wearing on myopia progress after cycloplegic refraction. Methods: The 33 people (66 eyes) were school children from 8 years to 12 years having no experience eye-glasses wearing, they were taken cycloplegic refraction at the 100th, the 200th and 300th days in order to evaluate myopia progression. We investigated the eye-glasses wearing group (experimental group, 32 eyes) and the non-eye-glasses wearing group (control group, 34 eyes). The eye-glasses power of the experimental group were -0.50 D, -0.75 D, -1.00 D, -1.25 D and -1.50 D. We compared experimental group with control group for myopia progress according to period, age, and refraction error and investigated the myopia progress according to the eye-glasses power of experimental group. Results: At the 300th day from the first cycloplegic refaction, spherical equivalent for the experimental group increased as -1.03${\pm}$0.43 D (t=13.36, p<0.001) and for the control group increase as -0.61${\pm}$0.35 D (t=10.05, p<0.001) and two groups were statistical difference. Myopia power for experimental group increased 60.75%, for control group increased 56.66% at the 300 days. According to eye-glasses power increased 41.19${\pm}$15.25% at -1.50 D, 36.74${\pm}$19.29% at -1.25 D, 56.57${\pm}$20.21% at -1.00 D, 87.26${\pm}$49.38% at -0.75 D and 106.69${\pm}$59.60% at -0.50 D. Conclusions: The myopia power for the eye-glasses wearing group was 0.46 D faster than the non-eye-glasses wearing group at the 300th day from the first cycloplegic refraction. We will consider the effect of non-eye-glasses wearing to protect the progressing myopia and prescribe the under correction for school children having no experience eye-glasses wearing.