• 제목/요약/키워드: Spherical power

검색결과 307건 처리시간 0.022초

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • 제20권4호
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

A Comparative Study on the Ametropias of Philippines and Koreans (한국인과 필리핀인의 굴절이상에 대한 연구)

  • Lee, Hark-Jun;Kwen, Man-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제17권4호
    • /
    • pp.477-482
    • /
    • 2012
  • Purpose: This study is aimed at finding the conditions of ametropia of adults in the Philippines and the South Korean. Methods: The study objects were 7,695(15,390 eyes) Koreans and 2,256(4,512 eyes) Philippines who visited optic clinics and took refraction test. The distributions of their hypermetropias and myopias about astigmatisms were examined, using the method of equivalent spherical power. When astigmatisms were marked in S-C, cylinder lens diopter and astigmatism axis, presbyopic additions and pupillary distances were analyzed by comparison respectively. Results: Among ametropias of Koreans myopias and hypermetropias were 93.69% and 6.31% respectively and about ametropias of Philippines myopia and hypermetropias were 73.43% and 26.57% respectively. As for spherical equivalent power about Koreans, the results showed that Koreans marked -3.352 D about myopia and Philippines marked -2.213 D about it. There is a gap of -1.139 D between them. About hypermetropia Koreans marked 1.147 D and Philippines, 1.251 D and their gap is 0.104 D. As for ametropia of Koreans there is 49.86% in middle myopia, 32.28% about low myopia, 11.55% about high myopia, and 5.54% about low hypermetropia, 0.75% about middle hypermetropia. As for it about Philippines there is 44.53% in low myopia, 25.11% about middle myopia, 3.79% high myopia and 23.03% low hypermetropia, and 3.51% low hypermetropia respectively. As for cylinder lens there is differences of 0.194 D and 0.22 D between Korean and Philippine for both sexes. Totally Koreans have higher cylinders of 0.175 D than Philippines. As for astigmatism, Koreans have direct astigmatism, inverse astigmatism, and oblique astigmatism in their suffering sequence. As for Philippines, they have direct astigmatism, inverse stigmatism, and oblique astigmatism in their abnormal sequence, and they have higher oblique stigmatism than Koreans. As for presbyopic addition, Philippines have higher distributions than Koreans, and 0.296 D is higher in average. As for pupillary distance, Koreans have longer distance of 0.97 mm in man and 0.63 mm in women than Philippines. Conclusions: As for ametropia, Koreans and Philippines have more myopias than hypermetropias, but Philippines have more rates of hypermetropias than Koreans. And Philippines have more presbyopic additions. Koreans have higher morbidity of inverse astigmatism, and Philippines have higher morbidity of oblique astigmatism comparatively. As for pupillary distance, Koreans have longer length in the body characteristics. This shows that geographical circumstances have much to do with refraction conditions of eyes.

A Study on the Measurement of Dynamic Visual Acuity according to the Change of Accommodative Stimulus (조절자극 변화에 따른 동체시력(Dynamic visual acuity) 측정에 관한 연구)

  • Jin, Moon-Seog;Jeon, In-Chul
    • The Korean Journal of Vision Science
    • /
    • 제20권4호
    • /
    • pp.523-530
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the difference in the dynamic visual acuity between (DVA) the distance and near and the effect of change of accommodative stimulus on the dynamic visual acuity by the addition of the plus lens. Methods : The study involved 40 male and female adults ($22.84{\pm}2.43$ years old) with over 1.0 of visual acuity and without systemic disease or ocular disease. We compared the distance and near DVA and the change of DVA induced by the addition of the plus lens(+0.50D, +1.00D, +1.50D). Results : The distance DVA and near DVA are $78.86{\pm}19.46deg/sec$ and $76.90{\pm}18.05deg/sec$ respectively. The distance DVA was slightly higher(p=0.04). The higher the distance DVA, the higher the positive correlation with the near DVA and distance DVA, and distance DVA was higher in those who had higher the near DVA(r=0.95, p=0.00, Fig. 4). The near DVA according to the change of accommodative stimulus was $75.95{\pm}18.85deg/sec$ in full correction and the near DVA with +0.50D spherical power was $76.95{\pm}16.45$ but there was no statistically significant differences(p>0.05). However, the near DVA with +1.00D spherical power was $79.02{\pm}13.51deg/sec$ and it was slightly higher. Also, the near DVA with +1.50D spherical power was $84.28{\pm}18.96deg/sec$, there and it was statistically significant difference(p<0.05). Conclusion : There is no difference between distance and near DVA, but near DVA is also excellent if distance DVA is good. The DVA increases as added a plus lens for controlled accommodative stimulation changes.

The Dioptric Differences between Both Eyes by Dioptric Power Matrix (굴절력 매트릭스에 의한 양안의 굴절력 차이)

  • Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제8권2호
    • /
    • pp.71-76
    • /
    • 2003
  • This study was performed to survey dioptric differences between the refractive states of both eyes from 1,100 patients who were given their prescriptions in spectacles. The differences were obtained by using dioptric power matrix. The prevalence of anisometropia was 96.9% for isoanisometropia, 2.9% for simple anisometropia, 0.2% for antimetropia. Spherical anisometropia was 22.1%, cylindrical anisometropia was 10.9%, spherocylindrical anisometropia was 46.5%, and no anisometropia was 20.5%. Anisometropia was more in thirties and forties than in other groups. In distribution of only spherical diopter differences, 76.1% were less than 0.50D, 91.7% were under 1.00D, only 2.5% were over 2.00D. In cylindrical diopter differences alone, 93.3% had under 0.50D, 1.7% had more than 1.00D. In spherocylindrical anisometropia, 52.8% were less than 0.50D, 78.6% were under 1.00D, 5.1% were more than 2.00D. In axis differences, with-the-rule type was 29.9%, against-the-rule type was 29.8%, oblique type was 40.3%.

  • PDF

Repeatability Assessment of Autorefractor and Accuracy Analysis of Refraction Measurements by Fourier Analysis (자동굴절검사기의 신뢰성 평가 및 Fourier analysis에 의한 정확도 분석)

  • Kim, Tae-Hun;Ye, Ki-Hun;Kim, Jae-Kwang;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제13권2호
    • /
    • pp.29-36
    • /
    • 2008
  • Purpose: We have evaluated both the reliability and accuracy of refractive measurement from autorefractor by comparing with subjective refraction data. Methods: Measurements of refractive error were performed on 198 eyes of 99 subjects in noncycloplegic condition. Also we analyzed refraction results and evaluated repeatability and accuracy of subjective refraction and autorefraction. Furthermore we analyzed accuracy of autorefractor by Fourier analysis. Results: Reliability coefficient of the autorefraction for the right eye were determined to by 0.993, 0.974 and 0.925 respectively, in the spherical, cylinderical component and cylinderical Axis. Also, the reliability coefficient of the autorefraction for the left eye were found to be 0.991, 0.948 and 0.886, respectively, in the spherical, cylinderical component and cylinderical Axis. From the Fourier analysis no statistically significant differences in $J_{0}$ component were found between the auto and subjective refraction measurements (p>0.05) whereas difference of refractive power of $J_{45}$ component when compared with the subjective refraction were -0.019, -0.164. Conclusions: We conclude that autorefractormeter can be effectively used to measure the refractive power within the error limits.

  • PDF

A Study for the Refractive Error in Middle and High School Pupils on the Basis of Their Glasses Power (안경도수를 근거로 한 중·고등학생의 굴절이상에 관한 연구)

  • Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제8권2호
    • /
    • pp.169-175
    • /
    • 2003
  • This research reviewed that 83 male subjects. 89 female subjects of middle and high school visited D Optical shop at the downtown of Daegu more than twice from January, 1999 to January, 2003 and obtained the following results by using the visual acuity prescription of them for which D Optical shop was keeping. 1. The classification of correction power for 190 myopia eyes was examined (87 male eyes, 103 female eyes) showed 89 eyes(46.82%) between $0.25D{\leq}3.00D$, 86 eyes(45.26%) between $3.25D{\leq}6.00D$, 15 eyes(7.89%) for over 6.25D. 2. The kind of 154 astigmatism subjects(79 male eyes, 75 female eyes) was direct astigmatism 83.77%, reverse astigmatism 11.69%, oblique astigmatism 4.55%. The cylindrical correction power for astigmatic eyes was 61 eyes(39.61%) between $0.25D{\leq}0.50D$, 60 eyes(38.96%) between 0.50D<1.00D, 121 eyes(78.57%) for less than 1.06D, 6 eyes(0.65%) for over 3.00D. 3. The variation of spherical power showed 161 eyes(46.80%) between $0.00D{\leq}0.50D$, 109 eyes(31.69%) between $0.51D{\leq}1.00D$, 17 eyes(4.94%) for over 2.01D variation. 4. The variation of astigmatic power showed 92 eyes(59.74%) between $0.00D{\leq}0.50D$, 39 eyes(25.32%) between $0.26D{\leq}0.50D$, 10eyes (6.49%) between $0.51D{\leq}0.75D$, 13 eyes(8.44 %) for over 0.76D astigmatic variation. 5. The variation of equivalent spherical power showed 137 eyes(39.83%) between $0.00D{\leq}0.50D$, 126 eyes(36.63%) between $0.51D{\leq}1.00D$, 40 eyes(11.63%) between $1.01D{\leq}1.50D$, 21 eyes(6.10%) between $1.51D{\leq}2.00D$, 20 eyes(5.81%) for over 2.01D variation.

  • PDF

The Influence of the Front Surface Power and the Refraction Index on RMS Spot Diameter (전면 굴절력과 굴절률이 착락원의 크기에 미치는 영향)

  • Park, Seong-Jong;Shin, Cheol-Guen;Ju, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제8권2호
    • /
    • pp.57-63
    • /
    • 2003
  • To investigate the RMS SD(Root Mean Square Spot Diameter) in a back focal plane as the front surface power, the center thickness, and the refraction index vary, we use programs which are Cove V and LOSA 2.0, and consider a spectacle lens with back vertex power of -4.00D and diameter of 70 mm. We also consider the front surface power varied from 0.00 to 10.00D, the center thickness varied from 1.1 to 2.0 mm, and the indices which are $n_d$ = 1.498, 1.523, 1.586, and 1.660, respectively. As the front surface power increases the RMS SD in the back focal plane increase rapidly. When the refraction index increases, the RMS SD in the back focal plane decrease and the variation of RMS SD in the back focal plane decreases as the front surface power increases. When the center thickness of spectacle lens increases, the RMS SD in the back focal plane is constant and the edge thickness of that increases. We know from these results that the image in the back focal plane of a spherical spectacle lens improves as the front surface power increases and the refraction index decreases.

  • PDF

Treatment of Spent ion-Exchange Resins from NPP by Supercritical Water Oxidation(SCWO) Process (초임계수 산화공정에 의한 원전 폐수지 처리기술)

  • Kim, Kyeong-Sook;Son, Soon-Hwan;Song, Kyu-Min;Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제7권3호
    • /
    • pp.175-182
    • /
    • 2009
  • The spent cationic exchange resins and anionic exchange resins were separated from mixed spent exchange resins by a fluidized bed gravimetric separator. The separated resins were identified by an elemental analysis and thermogravimetric analysis. The each test sample was prepared by diluting the slurry made by wet ball milling the cationic exchange resins and the anionic exchange resins separated as a spherical granular form for 24 hours. The resulting test samples showed a slurry form of less than $75{\mu}m$ of particle size and 25,000ppm of $COD_{cr}$. The decomposition conditions of each test samples from a thermal power plant were obtained with a lab-scale(reactor volume : 220mL) supercritical water oxidation(SCWO) facility. Then pilot plant(reactor volume : 24 L) tests were performed with the test samples from a thermal power plant and a nuclear power plant successively. Based on the optimal decomposition conditions and the operation experiences by lab-scale facility and the pilot plant, a commercial plant(capacity : 150kg/h) can be installed in a nuclear power plant was designed.

  • PDF

A Study for the Refractive Error on the Basis of Their Glasses Power (안경도수를 근거로 한 굴절이상에 관한 연구)

  • Jung, Han-Sub;Hong, Dong-Gyun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제9권2호
    • /
    • pp.431-437
    • /
    • 2004
  • This research reviewed the objects of 384 persons (male:86, female:298) from 6 to 50 years old visited the S. Optical shop at Mokpo over two times from Mar. 2002 to Feb. 2004. We obtained the following results by analyzing the visual acuity prescription to keeping at S. Optical shop. 1. The abnormal refraction eyes were 191 persons(49.74%) for simple myopia, 2 persons(0.52%) for myopic simple astigmatism, 180 persons(46.88%) for myopic compound astigmatism, and 1 person(0.26%) for simple hyperopia, 2 persons(0.52%) for hyperopic simple astigmatism, 8 persons(2.08%) for hyperopic compound astigmatism, respectively. 2. Classifying of correction power for 373 persons (male:84, female:289) myopia, so that showed 166 persons(male:36, female) between $$0.25D{\leq_-}2.00D$$, 194 persons(male:46, female:148) between $$2.25D{\leq_-}6.00D$$, 13 persons(male:2, female:11) for over 6.250 respectively. 3. According to the kinds of 192 persons astigmatism subjects(male:53, female:148), direct astigmatism was 145 persons(male:32, female:113), oblique astigmatism 33 persons (male:12, female:21), reverse astigmatism 14 persons(male:5, female:9). 4. The variation of spherical power for myopia showed 299 persons(male:71, female:228) between $$0.00D{\leq_-}0.50D$$, 64 persons(male:11, female:53) between $$0.51D{\leq_-}1.00D$$, 9 persons(male:2, female:7) between $$1.01D{\leq_-}1.50D$$, 1 person(male:0, female:1) between $$1.51D{\leq_-}2.00D$$ variation respectively. Hyperopia showed 8 persons(male:1, female:7) between $$0.00D{\leq_-}0.50D$$, 3 persons(male:1, female:2) between $$0.51D{\leq_-}1.00D$$ variation respectively. 5. The variation of astigmatism power showed 181 persons(male:48 female:113) between $$0.00D{\leq_-}0.25D$$, 25 persons(male:9, female:16) between $$0.26D{\leq_-}0.50D$$, 6 persons(male:0, female:6) between $$0.51D{\leq_-}0.75D$$ astigmatism variation respectively.

  • PDF

Plasma Engineering for Nano-Materials

  • Kim, Seong-In;Shin, Myoung-Sun;Son, Byung-Koo;Song, Seok-Kyun;Choi, Sun-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.79-79
    • /
    • 2012
  • A high temperature and a low temperature plasma process technologies were developed and demonstrated for synthesis, hybrid formation, surface treatment and CVD engineering of nano powder. RF thermal plasma is used for synthesis of spherical nano particles in a diameter ranged from 10 nm to 100 nm. A variety of nano particules such as Si, Ni, has been synthesized. The diameter of the nano-particles can be controlled by RF plasma power, pressure, gas flow rate and raw material feed rate. A modified RF thermal plasma also produces nano hybrid materials with graphene. Hemispherical nano-materials such as Ag, Ni, Si, SiO2, Al2O3, size ranged from 30 to 100 nm, has been grown on graphene nanoplatelet surface. The coverage ranged from 0.1 to 0.7 has been achieved uniformly over the graphene surface. Low temperature AC plasma is developed for surface modification of nano-powder. In order to have a three dimensional and lengthy plasma treatment, a spiral type of reactor has been developed. A similar plasma reactor has been modfied for nano plasma CVD process. The reactor can be heated with halogen lamp.

  • PDF