• Title/Summary/Keyword: Spherical lens

Search Result 198, Processing Time 0.027 seconds

Spherical and Aspherical RGP Lens Fitting to Epithelium and Endothelium of Rabbit's Cornea -Scanning Electron Microscopy (구면과 비구면 RGP 렌즈 장기 착용시 각막 상피, 내피에 미치는 영향-주사전자현미경적 관찰)

  • Kim, In-Suk;Ryu, Gun-Chang;Chae, Soo-Chul;Jeon, Chang-Jin
    • Applied Microscopy
    • /
    • v.36 no.3
    • /
    • pp.227-234
    • /
    • 2006
  • To investigate the comparative effect of spherical and aspherical RGP lens were worn during 3 weeks on rabbit's cornea. Four white rabbits were worn right eyes with spherical lens and 4 white rabbits were worn right eyes with aspherical RGP lens. Left eyes were served as control. The rabbits were sacrificed at 3 weeks after fitting and observed morphological changes by scanning electron microscopy and also investigate proliferation rate of the corneal epithelium with RGP wearing. After spherical RGP lens wearing, the epithet layer damaged compared to aspherical lens. The superficial cell layer strip off seriously, cell size significantly changed abnormal. Both spherical and aspherical RGP lens fitting group showed so many bacteria and back surface of lens was found like a fern shape. The aspherical RGP lens original material type was some formal than spherical lens. We thought that these pattern was significantly altered with spherical lens by prohibited transmitter oxygen from atmosphere therefore the epithelium shape was changed. This suggested wearing the aspherical lens might be less physiologic than shperical lens fitting.

Verification for transcription of spherical radius and prediction of birefringence in injection molding optical lens (초정밀 광학렌즈의 복굴절 예측과 금형 전사성)

  • Ohmori Hitoshi;Kwak Tae Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.55-60
    • /
    • 2005
  • This paper has been focused in developing of plastic lens with ultra-precision and low birefringence ability using by injection molding simulation tools. The simulation tools, $3D-Timon^{TM}\;and\;Asu-Mold^{TM}$ were applied to visualize indirectly the flow pattern of melted polymer enter the mould and the simulation results are verified as compared with the experimental results. Birefringence and polarized light generated in injection molding process was also calculated for each injection conditions and compared with .the pictures of experimented optical lens go through the polarized light plates device. A spherical radius of plastic optical lens transcribed from profile of mould core surface was measured to estimate the geometrical accuracy fer the each injection conditions. It is confirmed that the simulation results about flow pattern and polarized light area coincided in experimental results. It is known that increasing in thickness shrinkage at center of lens, the spherical radius is larger from comparing the graph measured spherical radius and the thickness shrinkage at center of lens

Changes of Stereoacuity with Correction in Induced Anisometropia (유발된 부동시의 교정에 따른 입체시 변화)

  • Choi, Jin Young;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.121-126
    • /
    • 2008
  • Purpose: To study the minimum diopter of spherical lens with normal binocular function in induced anisometropia by over-correction or under-correction in single eye. Methods: Stereoacuity of subjects without ophthalmic disease history in their twenties was measured by using Titmus-fly stereotest at 40 cm after overcorrection or under-correction in non-dominant eye or dominant eye, respectively. Results: In induced anisometropia, the stereoacuity decreased with increase of the power of added spherical lens in either nondominant eye or dominant eye. And the first reduction of stereoacuity was more prominent with the addition of (+) spherical lens than (-) spherical lens. In addition, there was more strikingly decrement of stereoacuity with addition of spherical lens to dominant eye than non-dominant eye. Conclusions: In induced anisometropia, the most outstanding reduction of stereoacuity was obtained with increment of the power of added (+) spherical lens in case of non-dominant eye with full correction and dominant eye with addition of spherical lens.

  • PDF

A Study on the Mirror Grinding for Mold of a Small Aspherical Lens

  • Lee, Joo-Sang;Masaru Saeki;Tsunemoto Kuriyagawa;Katsuo Syoji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.3
    • /
    • pp.48-54
    • /
    • 2003
  • This paper deals with mirror grinding of a small-sized aspherical lens by a resin bonded diamond spherical wheel. Up to now, a spherical lens has been used for the lens of the optical communication optical part. However, recently, aspherical optical parts are mainly used in order to attempt the improvement in image quality and miniaturization of the optical device. It is possible to manufacture the aspherical lens which is presently being used in optical instrument through ultra-precision machining technology. Also, to realize compactness, efforts are being made to produce a micro aspherical lens, fur which the development of a high-precision, micro molding die is inevitable. Therefore, extensive research is being done on methods of producing a micro aspherical surface by high-precision grinding. In this paper, the spherical wheel was trued by cup-shaped truer and tool path was calculated by the radius of curvature of the wheel after truing and dressing. Then in the aspherical grinding experiment, WC material which is used as a melding die for the small-sized aspherical lens was ground. The results showed that a form accuracy of 0.1918 $\mu\textrm{m}$ P-V and a surface roughness of 0.064 $\mu\textrm{m}$ Rmax could be achieved.

A Study on the Mirror Grinding for Mold of a Small Aspherical Lens (소형 비구면 렌즈 금형의 경면 연삭 가공에 관한 연구)

  • Lee, Joo-Sang;Saeki, Masaru;Kuriyagawa, Tsunemoto;Syoji, Katsuo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.82-87
    • /
    • 2001
  • This paper deals with mirror grinding of a small-sized aspherical lens by the resin bonded diamond spherical wheel. Up to now, a spherical lens has been used for the lens of the optical communication optical part. However, recently, the aspherical optical parts are mainly used in order to attempt the improvement in image quality and miniaturization of the optical device. It is possible to manufacture the aspherical lens which is presently being used in optical instrument through ultra-precision machinery technology. Also, to realize compactability, efforts are being made to produce a micro aspherical lens, for which the development of a high-precision, micro molding die is inevitable. Therefore, extensive research is being done on methods of producing an micro aspherical surface by high-precision grinding. In this paper, the spherical wheel was trued by cup-type truer and tool path was calculated by the radius of curvature of wheel after truing and dressing. And then in the aspherical grinding experiment, WC material which is used as a molding die for the small-sized aspherical lens was ground. It results was that a form accuracy of 0.1918${\mu}m$ P-V and a surface roughness of 0.064${\mu}m$ Rmax.

  • PDF

A Relationship between Corneal Type, Corneal Astigmatism and Lens Fitting States and the Stable Centration of Spherical RGP Lens (각막형상, 각막난시 및 렌즈 피팅상태와 구면 RGP렌즈의 중심안정위치와의 상관 관계)

  • Lim, Shin Gyu;Lee, Min Ha;Choi, Sun Mi;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.143-151
    • /
    • 2012
  • Purpose: The present study was conducted to investigate whether there is any difference in the centration of spherical RGP lens on cornea according to corneal types, corneal astigmatism and lens fitting states. Methods: Spherical RGP lens was fitted on 29 eyes of round-typed cornea and 45 eyes of symmetric bowtie-typed cornea with 0.00~2.75 D of corneal astigmatism in alignment, steep or flat. Their lens centrations on cornea were analyzed by taking photographs. Results: The centration of spherical RGP lens in the vertical direction was decentrated to downward direction in all cases, and the degree of decentration was not consistent. The lens centration in horizontal direction was significantly more-decentrated to the temporal meridian as base curve of lens was increased, and the degree of decentration was different according to the corneal type, corneal astigmatism and fitting states. With the same degree of astigmatism, the lens decentration to the temporal meridian was bigger in round-typed cornea than that in symmetirc bowtie-typed cornea. Conclusions: The centration of spherical RGP lens varies depending on lens fitting states, corneal astigmatism, and corneal types. Thus, the consideration of these factors may improve the success rate in RGP lens prescription.

Thermal Deformation Measurement Spherical Glasses Lens Using ESPI (ESPI를 이용한 안경용 렌즈의 열변형 측정)

  • Kim, Koung-Suk;Jang, Ho-Sub;Kim, Hyun-Min;Yang, Seung-Pill
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • The spherical glasses lenses are typically classified into two groups such as (+) diopter lens and (-) diopter lens by the refractive power index. The thermal deformation of a lens is occurred by external heat source and is changed respected to the diopter of a lens. In this paper, the thermal deformation of spherical glasses lenses were quantitatively measured by using ESPI (electronic speckle pattern interferometry) which has an advantage that the non-contact, non-destructive and precise deformation measurement is available due to the coherency characteristic. The temperature changes were measured by IR camera. It makes experiments over 14 types of the plastic glasses lenses. From the results, it was confirmed that the larger diopter lens showed the less thermal deformation in case of the (+) diopter lens. On the other hand, the thermal deformation of the (-) diopter lens was measured with uniform pattern when the same temperature changes were applied. Also, it was found that the thermnal deformation of the (+) diopter lens is less than that of the (-) diopter lens. Therefore, it is expected that when the thermal deformation is occurred to the various types of the lens, the variation of the focal length caused by the thermal distortion of a lens would be measured quantitatively.

A Study for Young and Middle Age People of Accommodation (청·장년층의 조절력에 관한 고찰)

  • Kim, Jeoung Hi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.129-136
    • /
    • 1998
  • I obtained result like these to practice accommodation test using Spherical Add method and Cross cylinder lens method. The 242 eyes(121 persons) in test was the young and middle age people and their age was from 19 to 41. 1. Using Spherical Add, I tested accommodation. The twenties's limits of accommodation were 9~13 Diopter, and thirties to fourties's limits of accommodation were 6~8.5 Diopter. 2. Using Cross cylinder lens in the test of accommodation twenties's average accommodation limits were appeared 6.13 Diopter~10.13 Diopter, thirties average accommodation limits were 5.75 Diopter~8.75 Diopter and fourties's average accommodation limits were 4.38 Diopter~7.25 Diopter. All men women have had more good accommodation of the horizontal direction than the vertical direction. 3. Using Spherical Add method and Cross cylinder lens method, the results of accommodation were shown like these. Accommodation that measured with spherical add method was more big than cross cylinder's accommodation measuring method. Finally I found the fact accommodation decreases as age goes.

  • PDF

A Relationship between Corneal Eccentricity and Stable Centration of RGP Lens on Cornea (각막 이심률과 RGP 렌즈의 중심안정위치와의 상관관계)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.373-380
    • /
    • 2012
  • Purpose: The present study was performed to investigate a relationship between the stable centrations of spherical RGP lens and aspherical RGP lens on cornea and corneal eccentricity. Methods: Two RGP lenses with different designs were fitted in alignment, steep or flat on total 84 eyes having corneal eccentricity of 0.28~0.78. The stable centration of lenses on cornea was analyzed by taking photographs with a high-speed digital camera. Results: The stable centrations of spherical and aspherical RGP lenses in horizontal direction were decentrated to temporal side. More centration to median side was shown when corneal eccentricity was larger. The difference between the stable centrations of spherical and aspheric RGP lenses according to corneal eccentricity was bigger when the fitting state was flatter. The difference in the stable centrations of aspherical RGP lens was smaller than that of spherical RGP lens regardless of fitting status. The stable centrations of spherical and aspherical RGP lenses in vertical direction were located below corneal apex regardless of fitting status however, there was no significant difference analyzed by the variation of corneal eccentricity. However, there were many cases that RGP lenses were in upper eyelid with increasing corneal eccentricity. Conclusions: The consideration of corneal eccentricity is required for RGP lens fitting and manufacturing aspherical RGP lens since the stable centration of spherical RGP lens as well as aspherical RPG lens' centration was changed depending on corneal eccentricity.

A Study on the Manufacturing Characteristics for Micro Spherical Lens Mold of Soft Materials (연질재료의 마이크로 구형렌즈금형 가공특성에 관한 연구)

  • 홍성민;이동주;제태진;최두선;이응숙
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1466-1469
    • /
    • 2004
  • Micro spherical lens mold processing method based on mechanical one completes a spherical shape by setting a diamond tool of hundreds $\mu$m radius on spins with high speed and then using Z-axis vertical feeding motion like the fabrication of micro drilling. In this method, we can see unprocessed parts shaped like cylinder and cone and check increasing chatter marks and burrs by setting errors of the central axis of rotation on the edge of the tool. That is why this method doesn't suit for the optical lens mold. In this paper presents unprocessed parts are disappeared and chatter marks and burrs are decreased from centre of the lens after using Run-out measuring and setting system on run-out occurred from setting tool. Also the fabrication characteristics of 6:4 Brass, A1601, PMMA are compared and analyzed, establishing the optimum machining condition on each material.

  • PDF