• Title/Summary/Keyword: Spherical capsule system

Search Result 8, Processing Time 0.026 seconds

Heat Transfer Characteristics of the Spherical Capsule Storage System Using Paraffins

  • Cho, Keum-Nam;Choi, S. H.
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.113-123
    • /
    • 1998
  • The present study is to investigate the effect of experimental parameters on the heat transfer characteristics of a spherical capsule storage system using paraffins. N-Tetradecane and mixture of n-Tetradecane 40% and n-Hexadecane 60% were used as paraffins. Water with inorganic material was also tested for the comparison. The experimental parameters were varied for the Reynolds number from 8 to 16 and for the inlet temperature from -7 to 2$^{\circ}C$. Measured local temperatures of spherical capsules in the storage tank were utilized to calculate charging and discharging times, dimensionless thermal storage amount, and the average heat transfer coefficients in the tank. Local charging and discharging times in the storage tank were significantly different. The effect of inlet temperature on charging time was larger than that on discharging time, but the effect of Reynolds number on charging time was smaller than that on discharging time. Charging time of paraffins was faster by 11~72% than that of water with inorganic material, but little difference of discharging time was found among them. The effect of Reynolds number on the dimensionless thermal storage was less during charging process and more during discharging process than the effect of inlet temperature. The effect of the inlet temperature and the Reynolds number on the average heat transfer coefficient of the storage tank was stronger during discharging process than during charging process. The average heat transfer coefficients of the spherical capsule system using paraffins were larger by 40% than those using water.

  • PDF

Thermal performance of the spherical capsule system using paraffin as the thermal storage material (파라핀 축열재를 사용한 구형캡슐 시스템의 전열성능)

  • Cho, K.N.;Choi, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.354-363
    • /
    • 1997
  • The purpose of the present work is to show the best thermal storage material and the sensitivity of the parameters on the thermal performance by experimentally investigating the effects of the parameters on the thermal performance of the spherical capsule system using paraffins superior to the commercial one. The paraffins were n-Tetradecane and the mixture of n-Tetradecane 40% and n-Hexadecane 60%. The experimental parameters were the Reynolds number of 8, 12, and 16 and the inlet temperature of-7, -4, -1, and $2^{\circ}C$. The charging and the discharing time, the dimensionless thermal storage amount, and the averge heat transfer coefficient in the tank were obtained by utilizing the local temperature variation in the tank. The local charging and discharging time in the tank was axially and radially different a lot. The effects of the inlet temperature on the charging and the discharging time were larger during the charging process than during the discharging process, but the effects of the Reynolds number on the charging and the discharging time were in reverse order. The paraffins were better by 11~72% than the water with the inorganic material in the charging time aspect, but no difference in the discharging time aspect. The effects of the Reynolds number on the dimensionless thermal storage amount were smaller than the effects of the inlet temperature during the charging process, but in reverse order during the discharging process within the working range of the experimental parameters. The effects of the inlet temperature and the Reynolds number on the average heat transfer coefficient were larger during the discharging process than during the charging process. The average heat transfer coefficient for the paraffins was larger by 40% maximum than that for the commercial material during the charing and the discharging process.

  • PDF

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Wireless Control System Using Spherical Camera (구형체 카메라를 이용한 무선 관제 시스템)

  • Jang, Jae-min;Shin, Soo Young;Ji, Yong-ju;Chae, Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.4
    • /
    • pp.461-466
    • /
    • 2016
  • In this paper, a capsule body shaped surveillance/monitoring device is developed. The device includes a camera and GPS module to transmit live video data and real time GPS coordinates respectively using the Intel Edison module. A control application is developed for the smart phones and tablets to wirelessly view the live video stream and location of the capsule device and also to switch between the multiple capsule devices installed at different locations. The coordination between the developed device and the smart phone / tablet is done using the wireless function of the Intel Edison module.

Poly(ε-caprolactone) Microcapsule with Encapsulated Nifedipine Prepared by Magnetic Stirrer

  • Lee, Hyeran;Lee, Deuk Yong;Song, Yo-Seung;Kim, Bae-Yeon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.7-14
    • /
    • 2019
  • The microencapsulation of nifedipine (NF) with 4 wt% of poly(${\varepsilon}-caprolactone$) (PCL)/polyvinylpyrollidone (PVP) or PCL/polyethylene glycol (PEG) was carried out by solvent evaporation method in oil in water emulsion system to investigate the effect of PVP and PEG addition on drug release behavior of the microcapsules. The PVA (emulsifier) concentration of 1.0 wt% was chosen for the formation of PCL capsule having an average size of $154{\pm}25{\mu}m$ due to nearly spherical shape with a narrow size distribution. As PCL/PVP and PCL/PEG ratios were raised from 10/0 to 6/4, the capsule size increased gradually from $154{\pm}25{\mu}m$ to $236{\pm}32{\mu}m$ and $248{\pm}56{\mu}m$, respectively. The drug release rate of PCL/PVP and PCL/PEG capsules increased dramatically from 0 to 4 h at the beginning and then reached the plateau region from 20 h. As the concentration of PVP or PEG increased, the amount of drug release increased, suggesting that the larger capsule size was attributed to the higher drug content. However, the drug release behavior remained almost constant. The PCL capsules exhibited no evidence of causing cell lysis or toxicity regardless of NF loading, implying that the microcapsules are clinically suitable for use as drug delivery systems.

Effect of Combination with Aspherical Lens in the Micro Optical System Design (마이크로 광학계의 설계에서 비구면 렌즈의 조합 효과)

  • 김명중;김한섭;박규열;전종업;김의중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1422-1425
    • /
    • 2003
  • In the design of optical system, important variables of optical system (including indices, shapes, spaces, stops. etc.) must manipulate in order to balance out offensive aberration. In this paper, it carried out a basic study on the design of micro optical system usable for the acquaintance of visual information in the particular conditions such as capsule type endoscopes. In this study, specification for design of optical system selected voluntarily and the basic design of optical system carried out by using the ray tracing method on the assumption that ideal lenses without aberrations. In the designed optical system, the optimization including aberration correction and the performance evaluation of optical system carried out by using the CODE-V. The final designed optical system consists of seven sheets of lenses. Also the results of performance evaluation. the micro optical system combined with aspherical lenses was confirmed to have improved optical performance as compared with the micro optical system consisted of spherical lenses.

  • PDF

Fabrication of Functional Microcapsule for Drug Delivery by using Droplet Phase Flow (Droplet 유동을 이용한 마이크로캡슐의 제작)

  • Jeong, Eun-Ho;Abraham, Sinoj;Kim, Il;Go, Jeung-Sang;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.89-92
    • /
    • 2005
  • A microcapsule for drug delivery was successfully produced by utilizing the flow-through droplet-based supramolecular self-assembly in a crossed microchannel network. The PS-b-PMMA block copolymer synthesized atom transfer radical polymerization (ATRP) was initially formed as microdroplets and after the evaporation process it turned to spherical capsule by polymer self-assembly of the micro domains. The characteristics were studied using various analysis methods.

  • PDF

ENHANCED BIOAVAILABILITY OF NIFEDIPINE USING COATED DRY ELIXIR

  • Park, Jae-Yoon;Kim, Chong-Kook
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.282-282
    • /
    • 1996
  • The purpose of this study was to prepare the nifedipine dry elixir (NDE) and coated nifedipine dry elixir (CNDE) containing nifedipine ethanol solution for improving the dissolution rate and bioavailability of nifedipine. NDE containing nifedipine and ethanol in wall materials of dextrin was prepared using a spray-dryer and then NDE was coated with eudragit acrylic resin to make CNDE. Shape and size of the NDE and CNDE were monitored by scanning electron micrograph and laser particle size analyzer In vitro dissolution tests were performed in simulated gastric and intestinal fluid. Bioavailability of NDE and CNDE were compared with drug powder suspension and commercial soft capsule after oral administration of the preparations to rats. NDE and CNDE are spherical in shape. Cross-sectional view of dry elixirs indicates the large inter cavity containing ethanolic drug solution in shell. Geometric mean diameter of NDE and CNDE is about 6.64 and 8.70 $\mu\textrm{m}$, respectively. Drug dissolution rate within first 5 min from NDE increased dramatically irrespective of dissolution medium. However, CNDE showed a particularly retarded dissolution rate in pH 1.2 simulated gastric fluid compared with NDE. The bioavailability of nifedipine in the NDE was increased dramatically compared with drug powder suspension. CNDE reduced initial burst-out plasma peak compared with NDE. CNDE as a sustained release delivery system could reduce the initial burst-out plasma peak due to controlling the release rate of nifedipine from NDE and maintain the effective plasma level over a longer period within therapeutic window with enhanced bioavailability of nifedipine.

  • PDF