• Title/Summary/Keyword: Speed change

Search Result 3,185, Processing Time 0.039 seconds

The evaluation for the usability ofthe Varian Standard Couch modelingusing Treatment Planning System (치료계획 시스템을 이용한 Varian Standard Couch 모델링의 유용성 평가)

  • Yang, yong mo;Song, yong min;Kim, jin man;Choi, ji min;Choi, byeung gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.77-86
    • /
    • 2016
  • Purpose : When a radiation treatment, there is an attenuation by Carbon Fiber Couch. In this study, we tried to evaluate the usability of the Varian Standard Couch(VSC) by modeling with Treatment Planning System (TPS) Materials and Methods : VSC was scanned by CBCT(Cone Beam Computed Tomography) of the Linac(Clinac IX, VARIAN, USA), following the three conditions of VSC, Side Rail OutGrid(SROG), Side Rail InGrid(SRIG), Side Rail In OutSpine Down Bar(SRIOS). After scan, the data was transferred to TPS and modeled by contouring Side Rail, Side Bar Upper, Side Bar Lower, Spine Down Bar automatically. We scanned the Cheese Phantom(Middelton, USA) using Computed Tomography(Light Speed RT 16, GE, USA) and transfer the data to TPS, and apply VSC modeled previously with TPS to it. Dose was measured at the isocenter of Ion Chamber(A1SL, Standard imaging, USA) in Cheese Phantom using 4 and 10 MV radiation for every $5^{\circ}$ gantry angle in a different filed size($3{\times}3cm^2$, $10{\times}10cm^2$) without any change of MU(=100), and then we compared the calculated dose and measured dose. Also we included dose at the $127^{\circ}$ in SRIG to compare the attenuation by Side Bar Upper. Results : The density of VSC by CBCT in TPS was $0.9g/cm^3$, and in the case of Spine Down Bar, it was $0.7g/cm^3$. The radiation was attenuated by 17.49%, 16.49%, 8.54%, and 7.59% at the Side Rail, Side Bar Upper, Side Bar Lower, and Spine Down Bar. For the accuracy of modeling, calculated dose and measured dose were compared. The average error was 1.13% and the maximum error was 1.98% at the $170^{\circ}beam$ crossing the Spine Down Bar. Conclusion : To evaluate the usability for the VSC modeled by TPS, the maximum error was 1.98% as a result of compassion between calculated dose and measured dose. We found out that VSC modeling helped expect the dose, so we think that it will be helpful for the more accurate treatment.

  • PDF

Voluntary Motor Control Change after Gait Training in Patients with Spinal Cord Injury (척수신경손상 환자의 보행훈련 전.후의 능동적 근육제어의 변화)

  • 임현균;이동철;이영신;셔우드아더
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.133-140
    • /
    • 2003
  • In this study, muscle activity was measured using surface EMG (sEMG) during a voluntary maneuver (ankle dorsiflexion) in the supine position was compared pre and post gait training. Nine patients with incomplete spinal cord injury participated in a supported treadmill ambulation training (STAT), twenty minutes a day, five days a week for three months. Two tests, a gait speed test and a voluntary maneuver test, were made the same day, or at least the same week, pre and post gait training. Ten healthy subjects' data recorded using the same voluntary maneuvers were used for the reference. sEMG measured from ten lower limb muscles was used to observe the two features of amplitude and motor control distribution pattern, named response vector. The result showed that the average gait speed of patients increased significantly (p〈0.1) from 0.47$\pm$0.35 m/s to 0.68$\pm$0.52 m/s. In sEMG analysis, six out of nine patients showed a tendency to increase the right tibialis anterior activity during right ankle dorsiflexion from 109.7$\pm$148.5 $mutextrm{V}$ to 145.9$\pm$180.7 $mutextrm{V}$ but it was not significant (p〈0.055). In addition, only two patients showed increase of correlation coefficient and total muscle activity in the left fide during left dorsiflexion. Patients' muscle activity changes after gait training varied individually and generally depended on their muscle control abilities of the pre-STAT status. Response vector being introduced for quantitative analysis showed good Possibility to anticipate. evaluate, and/or guide patients with SCI, before and after gait training.

A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane (소형 어로 크레인의 동적 거동 특성에 관한 연구)

  • 이원섭;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.163-173
    • /
    • 2001
  • The dynamic behavior characteristics of a small fishing crane for inshore and coastal fishing vessels was experimentally analyzed in order to improve the fishing operation and to reduce considerably manual work of fisherman. The small fishing crane was designed to be controlled electro-hydraulically by means of proportional valves and solenoid valves, and also to be controlled the speed of each operation. The dynamic behavior characteristics was investigated by measuring the changes of parameters such as oil pressure, swing angle of load, load tension, the lifting angle and the swing angle of crane arm when the arms extended in a side way was given a test load. The results obtained are summarized as follows: 1. The designed small fishing crane can be proportionally controlled by means of proportional valves and rapidly by operating the solenoid valves, respectively. The capacity, turning angle, maximum reach of crane were 2 T-M, $180^\circ$, 3.7m, respectively. 2. The vertical change of crane arm on the extension of lifting cylinder was $1.2^\circ$/cm, and the swing speed of crane arm due to the extension of swing cylinder by on/off operations of solenoid valves was $15^\circ$/sec, with the swing period of 1.4 sec and the angle fluctuation of $\pm$11.0$^{\circ}$. 3. When changing simultaneously the horizontal and vertical positions of the lifting load by on/off operations of solenoid valves, the swing and lifting speeds of crane arm were $4.46^\circ$/sec and $6.4^\circ$/sec, respectively. 4. The movements of the designed crane were particularly smooth as they are controlled with the aid of proportional valves than by means of solenoid valves.

  • PDF

Development of an Solid Separation System for Pig Slurry (돈 슬러리용 고형물 분리시스템 개발)

  • 김민균;김태일;최동윤;백광수;박진기;양창범;탁태영
    • Journal of Animal Environmental Science
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was conducted to develope the new solid separating system which can be efficiently and economically removed the solid parts in high pollutants concentration of pig slurry. The pollutants concentration, BOD$_{5}$ , COD and SS of the slurry used in this study was 15,990($\pm$2,389)mg/l, 20,004($\pm$5,512)mg/l and 26,486($\pm$5,935)mg/l, respectively. After removal of solid part in slurry, the pollutants concentration, BOD$_{5}$, COD and SS was change into 5,617($\pm$690)mg/l, 5,553($\pm$633)mg/land 1,456($\pm$341)mg/l, respectively in the Fixed biological membrane tank. The reduction of the pollutants concentration of suspend liquid through membrane will be allowed to greatly improve the water purification by an Activated sludge method. This separating system consisted of a temporary storage, a circulating tank and a Fixed Biological membrane tank. A temporary storage which has a draining system of screw type and an aeration device played a tremendous role in draining the solid by filled an aeration of 0.3 l/min. A Fixed Biological membrane tank of which a styrofoam filled in a 2/3 volume as a Biological media was fixed by a stainless steel net (pore size : 0.5mm) to separate the liquid layer of influx in them. The separating system efficiency factors were the speed of screw motor, cycle number of slurries in a circulating tank and moisture contents of solid effluent through the screw path. Although the pollutants concentration was very variable in temporary storage, the final concentration of $BOD_5$ and SS, except COD of the suspended liquid in a Fixed biological membrane were not different regardless of cycle number of a circulating tank. Moisture contents of effluent from temporary storage was 73% under the speed 1 ppm of screw motor and 62% under the 1/4rpm of it.

  • PDF

Quality Change during Harvest Time and Storage of Various Cabbages Grown on High Land by Different Transplanting Times (정식시기에 따른 고랭지 양배추의 수확 및 저장중 품질변화)

  • Eum, Hyang-Lan;Lee, Young-Hoon;Hong, Sae-Jin;Shin, Il-Sheob;Yeoung, Young-Rok
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.95-101
    • /
    • 2012
  • This study was conducted to investigate the effect of climate conditions during cultivation and harvesting on the quality and storability of fresh bulb cabbage (Brassica oleracea L. var. capitata). Plug seedlings of six cabbage cultivars were transplanted to Gangneung-Wonju University high elevation research station in Gangwon province (780 m above sea level, lat. $37.5^{\circ}N$.) and harvested with four different harvest times like August 3 ($1^{st}$), August 13 ($2^{nd}$), August 23 ($3^{rd}$), and September 10 ($4^{th}$), respectively from 50 days after transplanting. Weight loss, Hunter color factors, firmness, and soluble solids content (SSC) of the cabbage bulbs were investigated during storage at $3^{\circ}C$ (85% RH) and $25^{\circ}C$ (60% RH). Decreased bulb weight and poor quality cabbages were apparent at the late transplanting (July 14) and harvest (September 10) respectively. Quality index such as firmness and SSC at August 23 ($3^{rd}$) harvested cabbage was better than August 3 ($1^{st}$) and August 13 ($2^{nd}$) cabbages due to the good weather condition just before harvesting. The cv. 'Speed king' and 'Minix 40' showed good qualities among the cultivars, especially when the bulbs were harvested during sunny day conditions from one week before harvesting. Also SSC was influenced by weather condition before harvesting rather than transplanting date, while firmness was influenced by transplanting and harvest date. However, the differences among the cultivars were not significant. The potential of storage as maintaining the quality was different, depending on weather conditions at harvest time. Generally the storage periods of six cultivars were around 3~5 days and 9~10 days at room and low temperature, respectively. However, the August 3 ($1^{st}$) harvested cabbage lost their marketable quality very fast because of rainy and cloudy weather condition before harvesting and also storability of bulbs was 2 days and 4 days at room temperature and $3^{\circ}C$, respectively. Quality index was also not significant difference among cultivars.

Effect of PE Film Mulching and Irrigation Method on the Growth, Yield and Antioxidant Activity for Potatoes Grown in Winter Season at Saemangeum Reclaimed Land (새만금 간척지에서 감자 겨울재배시 비닐멀칭 및 관수방법이 생육, 수량 및 괴경의 항산화 활성에 미치는 영향)

  • Choi, Weon-Young;Cho, Kwang-Min;Kim, Sun;Jeong, Jae-Hyeok;Lee, Su-Hwan;Lee, Kyeong-Bo;Lee, Geon-Hwi;Park, Ki-Hun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.63-69
    • /
    • 2015
  • This study was conducted to measure the effect of PE film mulching and irrigation methods on the growth, yield and antioxidant activity of potatoes tubers, in order to examine the possibility of cultivating potatoes in winter season in vinyl greenhouse on the reclaimed tidal land with weak ground inside the sea wall currently completed. The test was conducted on the sandy loam soil (Munpo series), and its salt concentration was 0.42% at the time of planting. The emergence speed per kind of PE film mulching was in the order of black > coloration > transparent > green color, with the black color showing the fastest speed. The temperature change during a day per kind of PE film mulching was in the order of transparent > coloration > green > black color. As for the salt concentration in the soil for each different way of water management, the salt concentration in the treatment of drip irrigation with 1 week interval was lower than that drip irrigation with 2 weeks interval. As for the growth of above-aerial part, plant length was higher, number of tiller and leaves were more and dry weight of above-aerial part was larger in the treatment of drip irrigaton with 1 week interval than drip irrigation with 2 weeks interval. As for the yield of potatoes depending on each way of water management, the yield in the treatment of drip irrigation with 1 week interval was more than drip irrigation with 2 weeks interval. The yield for each different kind of PE film mulching in the weekly drip-irrigation management section was in the order of transparent ${\geq}$ black ${\geq}$ coloration ${\geq}$ green color. In both of total phenol content and DPPH free radical activity experiments, the content and activity were higher with pear color vinyl treatment.

A study on Categorized type and range for the Aircraft and the LSA (우리나라 항공기 및 경량항공기의 종류 및 범위에 대한 법적 고찰)

  • Kim, Woong-Yi;Shin, Dai-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.55-71
    • /
    • 2013
  • By aircraft from Aviation regulations and institutional regulatory framework for ensuring the safety is secured. State-of-the-art aircraft, according to the type of development and diversification, modernization and new types of aircraft are operated. In particular, light aircraft and ultralight flying device such as the gyro-plane and unmanned flying devices is introduced a new device, and the device operates at these flight in accordance with the standards of the Aviation Act regulations may not occur often. Variety of light aircraft and ultra-light aircraft assembly, can be adapted for a person engaged in the business of aviation safety management and to perform the legal basis was established. Depending on the classification of newly introduced aircraft, the biggest change is the introduction of the concept of the LSA. In Korea, the various light aircraft are operating, but these aircraft range not clearly Aviation Regulations had difficulty in ensuring safety. This study examined the differences between international rules and regulations of Korea about the classification of aircraft. The LSA are included in aircraft categories internationally, but LSA will not be included in the aircraft categories, which is one of a range of powered flight device exists in Korea Aviation Act. Limit for maximum continuous power speed in a LSA, it is a limit on the right of the people who want using the high-performance plane. Also it is an international trend does not fit in, and is consistent with the intent of LSA manufacturer. Delete the content from a range of future aviation law revisions and light aircraft-related provisions to limit the maximum continuous power speed is considered to be suitable for the purpose of introducing the light aircraft industry. The laws and regulations set up in order to ensure the safety of ultralight aircraft categories existing in ultralight aircraft that exceeds the purpose of the introduction of LSA technology development at home and abroad, and is intended to reflect. These standards complement of aircraft operation is not appropriate for the situation unless the country is difficult to ensure the safety of operations. Also developed in other countries, the introduction of aircraft operating in the country, so many problems occur early revision is required.

  • PDF

The Study of Visual Fatigue by Monitor Letter Contrast with an Eye Tracker (아이트래커를 이용한 모니터 글자 대비도에 따른 눈의 피로도 연구)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.533-538
    • /
    • 2014
  • Purpose: This study is to investigate correlation between eye fatigue and letter contrast according to letter contrast changes on monitor display. Methods: Reading speed test were carried out for 53 subjects (mean age: $22.68{\pm}1.85$ years) who have over Best-corrected visual acuity (BCVA) 1.0, and 45 subjects, who could read over 123 out of 163 letters among 53 subjects were selected. They were asked to read the letters which were composed of Black (contrast 100%), Dark gray (contrast 80%), Gray (contrast 80%), Light gray (contrast 30%) randomly. The change of their eye fatigue by letter contrast on monitor display was measured by monitoring their eyes with an eye-tracker while they were reading letters. Results: Event Duration (sec) was 33.635 for Black, 32.266 Dark gray, 33.936 for Gray, and 34.848 for Light gray. Average of Fixation Duration (sec) was 0.224 for Black, 0.218 for Dark gray, 0.239 for Gray and 0.243 for Light gray. Average of Pupil diameter (mm) was 41.133 mm for Black, 41.160 mm for Dark gray, 40.880 mm for Gray and 40.459 mm for Light gray. Frequency (blinks/sec) was 0.211 for Black, 0.206 for Dark gray, 0.221 for Gray, and 0.238 for Light gray. Conclusions: Event Duration and average of Fixation Duration were the shortest for Dark gray and the longest for Light gray. In average Pupil diameter was the biggest Dark gray and the smallest for Light gray. Blink Frequency (blinks/sec) was the lowest for Dark gray and the highest for Light gray. Visual fatigue by brightness of letters on monitor display was the least for Dark gray followed by Black, Gray and Light gray.

Analysis of Surface Sound Channel by Low Salinity Water and Its Mid-frequency Acoustic Characteristics in the East China Sea and the Gulf of Guinea (동중국해와 기니만에서 저염분수로 인한 표층음파채널과 중주파수 음향 특성 분석)

  • Kim, Hansoo;Kim, Juho;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • Salinity affects sound speed in the low salinity environment, in the seas where freshwater from large rivers and flows into the marginal sea area near the Yangtze River and the Niger River. In this paper, SSC (Surface Sound Channel) formed by low salinity water was investigated in the East China Sea and the Gulf of Guinea of rainy season. The data from KODC (Korea Oceanographic Data Center) in the East China Sea and from ARGO (Array for Real-time Geostrophic Oceanography) in the Gulf of Guinea of the tropical area were used for analysis. SSC haline channel was formed 14 times among 32 SSC occurrences when the 90 data from 9 points were analyzed during a decade (2000 ~ 2009) in the East China Sea. In the Gulf of Guinea, haline channel was formed 18 times among 20 SSC occurrences during 3 years (2006 ~ 2009). When the sound speed gradient was analyzed from temperature-salinity gradient diagram, the gradients of both salinity and temperature affect SSC formation in the East China Sea. In contrast, the salinity gradient mostly affects SSC formation due to the least change of temperature in the well-developed mixed layer in the Gulf of Guinea. Their acoustic characteristics show that channel depth is 6.5 m, critical angle is $1.5^{\circ}$ and difference of transmission loss between surface and thermocline is 11.5 dB in the East China Sea, while channel depth is 18 ~ 24 m, critical angle is $4.0{\sim}5.4^{\circ}$ and difference of transmission loss is 21.5 ~ 27.9 dB in the Gulf of Guinea. These results are expected to be used as a basic understanding of the acoustic transmission changes due to low salinity water at the estuaries and the ocean with heavy precipitation.

Influences of Unilateral Mandibular Block Anesthesia on Motor Speech Abilities (편측 하악전달마취가 운동구어능력에 미치는 영향)

  • Yang, Seung-Jae;Seo, In-Hyo;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.59-67
    • /
    • 2006
  • There exist patients complaining speech problem due to dysesthesia or anesthesia following dental surgical procedure accompanied by local anesthesia in clinical setting. However, it is not clear whether sensory problems in orofacial region may have an influence on motor speech abilities. The purpose of this study was to investigate whether transitory sensory impairment of mandibular nerve by local anesthesia may influence on the motor speech abilities and thus to evaluate possibility of distorted motor speech abilities due to dysesthesia of mandibular nerve. The subjects in this study consisted of 7 men and 3 women, whose right inferior alveolar nerve, lingual nerve and long buccal nerve was anesthetized by 1.8 mL lidocaine containing 1:100,000 epinephrine. All the subjects were instructed to self estimate degree of anesthesia on the affected region and speech discomfort with VAS before anesthesia, 30 seconds, 30, 60, 90, 120 and 150 minutes after anesthesia. In order to evaluate speech problems objectively, the words and sentences suggested to be read for testing speech speed, diadochokinetic rate, intonation, tremor and articulation were recorded according to the time and evaluated using a Computerized Speech $Lab^{(R)}$. Articulation was evaluated by a speech language clinician. The results of this study indicated that subjective discomfort of speech and depth of anesthesia was increased with time until 60 minutes after anesthesia and then decreased. Degree of subjective speech discomfort was correlated with depth of anesthesia self estimated by each subject. On the while, there was no significant difference in objective assessment item including speech speed, diadochokinetic rate, intonation and tremor. There was no change in articulation related with anesthesia. Based on the results of this study, it is not thought that sensory impairment of unilateral mandibular nerve deteriorates motor speech abilities in spite of individual's complaint of speech discomfort.