파워 조절 방법에 따른 풍력 터번 발전기의 방사 소음 특성 (Characteristics of Noise Emission from Wind Turbine Generator According to Methods of Power Regulation)

  • 정성수;정완섭;신수현;전세종;최용문;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.941-945
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and fun span pitch control. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbine generators (WTG) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. It is found that while 1.5 MW WTG using the stall control is found to emit lower sound power than 660 kW one using the pitch control at low wind speed (below 8 m/s), sound power from the former becomes greater than that of the latter in the higher wind speed. Equivalent continuous sound pressure levels (ECSPL) of the stall control type of WTG vary more widely with wind speed than those of the pitch control type of WTG These characteristics are believed to be strongly dependent on the basic difference of the airflow around the blade between the stall regulation and the pitch control types of WTG. These characteristics according to the methods of power regulation lead to the very different noise emission characteristics of WTG depending on the seasons because the average wind speed in summer is lower than the critical velocity over which the airflow on the suction side of blade in the stall types of WT are separated. These results propose that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

  • PDF

양수발전소 속도조정율 향상 및 수력적 부도시간에 관한 연구 (A study on the speed regulation improvement and water starting time of pumped storaged power plant)

  • 최인규;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.743-745
    • /
    • 1999
  • In these days, pumped storaged power plants are under operations mainly for load regulation in power system. After we investigated the governor related electrical circuit of a pumped storaged power plant, we measured speed regulation and dead time of both the governor and the hydraulic system according to the change of variables of the governor during generation. After that the measured speed regulation improved much.

  • PDF

분기기 통과속도 제한규정에 대한 타당성 검토 (Verification of the Reasonableness for the speed-limit regulation on the Turnout)

  • 정우진;나성훈;함영삼;문경호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1047-1056
    • /
    • 2004
  • The turnout system is typical railway facility to be in the way of conventional railway line's speed-up. The KNR(Korean National Railroad) :has a speed limit regulation(130km/h) for the passing the turnout to guarantee a safety. This research had been performed to confirm the propriety of this regulation by using experimental and analytical way before it was carried out. The reasonableness of the speed-limit regulation was judged base on the several experiments. It was proved that the regulation was not useless as it had been regarded and very important guide at least up to now.

  • PDF

분기기 통과속도 제한규정에 대한 타당성 검토연구 (Verification of the Validity for the Speed-limit Regulation on the Turnout System)

  • 정우진;구동회;양신추
    • 한국철도학회논문집
    • /
    • 제8권1호
    • /
    • pp.93-100
    • /
    • 2005
  • The turnout system is typical railway facility to be in the way of conventional railway line's speed-up. The KNR(Korean National Railroad) has a speed limit regulation (130km/h) for the passing the turnout to guarantee a safety. This research had been performed to confirm the propriety of this regulation by using experimental and analytical way before it was carried out. The reasonableness of the speed-limit regulation was judged base on the several experiments. It was proved that the regulation was not useless as it had been regarded and very important guide at least up to now.

Improved BP-NN Controller of PMSM for Speed Regulation

  • Feng, Li-Jia;Joung, Gyu-Bum
    • International journal of advanced smart convergence
    • /
    • 제10권2호
    • /
    • pp.175-186
    • /
    • 2021
  • We have studied the speed regulation of the permanent magnet synchronous motor (PMSM) servo system in this paper. To optimize the PMSM servo system's speed-control performance with disturbances, a non-linear speed-control technique using a back-propagation neural network (BP-NN) algorithm forthe controller design of the PMSM speed loop is introduced. To solve the slow convergence speed and easy to fall into the local minimum problem of BP-NN, we develope an improved BP-NN control algorithm by limiting the range of neural network outputs of the proportional coefficient Kp, integral coefficient Ki of the controller, and add adaptive gain factor β, that is the internal gain correction ratio. Compared with the conventional PI control method, our improved BP-NN control algorithm makes the settling time faster without static error, overshoot or oscillation. Simulation comparisons have been made for our improved BP-NN control method and the conventional PI control method to verify the proposed method's effectiveness.

파워 조절 방법에 따른 풍력 터빈의 방사 소음 특성 (Characteristics of Noise Emission from Wind Turbine According to Methods of Power Regulation)

  • 정철웅;정완섭;신수현;전세종;최용문;정성수
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.864-871
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and full span pitch control. The main purpose of this paper is to experimentally identify the characteristics of noise emission of wind turbines according to the power regulation types. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines (WT) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence, third-octave band levels and tonality are evaluated for both of WTs. It is observed that equivalent continuous sound pressure levels (ECSPL) of the stall control type of WT continue to increase with increasing wind speed whereas those of the pitch control type of WT show less correlation with wind speed. These observed characteristics are believed to be due to the different airflow patterns around the blade between the stall regulation and the pitch control types of WT; the airflow on the suction side of blade in the stall types of WT are separated at the high wind speed. It is also found that the 1.5 MW WT using the stall control emits lower sound power than 660 kW one using the pitch control at wind speeds below 8m/s, whereas sound power of the former becomes higher than that of the latter in the wind speed over 8m/s. This wind-speed dependence of sound power leads to the very different noise omission characteristics of WTs depending on the seasons because the average wind speed in summer is lower than 8m/s whereas that in summer is higher. Based on these experimental observations, it is proposed that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

ATO 장치의 자동 열차속도 조절 알고리즘에 관한 연구 (A Study for Automatic Train Speed Regulation Algorithm of ATO)

  • 김중환;강리택
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.210-218
    • /
    • 1998
  • The ATO(Automatic Train Operation) System is used for train operation instead of drivers. It is interfaced with TCMS(Train Control and Monitoring System) and ATC/TWC system in the train and wayside facilities. In this paper describes configuration of ATO, specification of ATO hardware, construction of ATO software and the algorithm fur automatic train speed regulation in the carborn ATO system. ATO Application Software is consist of ART, SPR, REG, SRV and PSM tasks. ART task is main control part of the ATO that determine ATO control, ATO mode, state transition. SPR determine speed reference according to train motion status, track data, train data and restricted train speed. REG task regulated train speed form the starting of one station to the precision stop at the other station under the result of ART and SPR tasks. In this paper, a algorithm for the train speed regulation while running is described.

  • PDF

A Modular Disturbance Observer-based Cascade Controller for Robust Speed Regulation of PMSM

  • Kim, In Hyuk;Son, Young Ik
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1663-1674
    • /
    • 2017
  • This paper deals with the robust speed regulation of a surface-mounted permanent magnet synchronous motor (SPMSM) that is subject to parametric uncertainties and external disturbances. The proposed approach retains a conventional cascade control configuration composed of an outer-loop speed control module and inner-loop current control modules. Baseline proportional-integral (PI) controllers are designed for nominal modular systems without accounting for the uncertainties to set a desired control performance of the closed-loop system. After studied in both frequency and time domains, a reduced-order proportional-integral observer (PIO), as a modular disturbance observer, is incorporated with each control module to maintain the ideal performance of the modules. Theoretical analysis confirms the desired performance recovery of the augmented system with modular PIOs to the nominal system. Comparative computer simulations and experimental results validate the proposed cascade control method for SPMSM speed regulation.

Static VAR Compensator-based Feedback Control Implementation for Self-Excited Induction Generator Terminal Voltage Regulation Driven by Variable-Speed Prime Mover

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.65-76
    • /
    • 2004
  • In this paper, the steady-state analysis of the three-phase self-excited induction generator (SEIG) driven by a variable-speed prime mover (VSPM) such as a wind turbine is presented. The steady-state torque-speed characteristics of the VSPM are considered with the three-phase SEIG equivalent circuit for evaluating the operating performances due to the inductive load variations. Furthermore, a PI closed-loop feedback voltage regulation scheme based on the static VAR compensator (SVC) for the three-phase SEIG driven by the VSPM is designed and considered for the wind power generation conditioner. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of fast response and high performances.

고속선의 새로운 국제안전규칙 -화재안전규칙에 대하여- (International Code of Safety Regulation for High Speed Craft - as compared with Fire Safety Regulation-)

  • 박영규;신영식
    • 해양환경안전학회지
    • /
    • 제3권1호
    • /
    • pp.111-123
    • /
    • 1997
  • The application of all regulations during building phase, plus constant vigilance in operation is essential to reducing the risk of fire aboard. A Safety by design approach is increasingly important. Fire safety regulation can solve problems which are hard to be solved by HSC code(International Code of Safety for High Speed Craft). Recently HSC code is applied for ship design development or guidance to the designer and demonstrates many advantages. In this pages, ship fire Safety are realistically modeled as ship design and the shipboard fires & muster stations are analyzed using HSC Code.