• 제목/요약/키워드: Speed Control Loop

검색결과 542건 처리시간 0.02초

치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향 (TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH)

  • 김성오;최병재;이제호;손흥규
    • 대한소아치과학회지
    • /
    • 제25권2호
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구 (Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System)

  • 강훈;정종호;정민우;지용남;유용선;최희주;변영만;김영진;오광윤;김용찬
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.431-439
    • /
    • 2013
  • 항공전자기기의 정상적인 동작을 위해서는 내부에서 발생되는 열부하를 적절히 처리해야 하기 때문에 냉각시스템의 장착이 요구된다. 본 연구에서는 항공용 냉각시스템으로의 대체냉매 적용 가능성을 분석하기 위하여 증기압축 사이클 방식의 밀폐 공기순환 냉각시스템을 설계 제작하였다. 대체냉매로 가장 유력한 R236fa를 냉각시스템에 적용하여 냉매 충전량, 팽창밸브 개도, 그리고 압축기 운전회전수 변화에 따른 성능특성을 실험적으로 고찰하였다. 또한, 실험결과를 기존 냉매인 R124의 실험결과와 비교 평가를 수행하여, R236fa가 대체냉매로서 적용 가능함을 확인하였다. 최종적으로 R236fa를 적용한 냉각시스템의 효율 향상을 위한 설계 개선안을 제시하였다.