• Title/Summary/Keyword: Spectroscopy, near-infrared

검색결과 681건 처리시간 0.029초

근적외선 분광법 및 확산 광 영상법의 최근 연구 동향 (Medical Applications of Near Infrared Spectroscopy and Diffuse Optical Imaging (Review))

  • 이승덕;권기운;고달권;김법민
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권2호
    • /
    • pp.89-98
    • /
    • 2008
  • NIRS (Near-infrared Spectroscopy) and DOI (Diffuse Optical Imaging) are relatively new, non-invasive, and non-ionizing methods that measure or image optical properties (Scattering and Absorption Coefficient) and physiological properties (Water Fraction, concentration of Oxy-, Deoxy-Hemoglobin, Cytochrome Oxidase, etc) of biological tissues. In this paper, three different types of NIRS systems, mathematical modeling, and reconstruction algorithms are described. Also, recent applications such as functional brain imaging, optical mammography, NIRS based BMI (Brain-Machine Interface), and small animal study are reviewed.

Partial Least Squares-discriminant Analysis for the Prediction of Hemodynamic Changes Using Near Infrared Spectroscopy

  • Seo, Youngwook;Lee, Seungduk;Koh, Dalkwon;Kim, Beop-Min
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.57-62
    • /
    • 2012
  • Using continuous wave near-infrared spectroscopy, we measured time-resolved concentration changes of oxy-hemoglobin and deoxy-hemoglobin from the primary motor cortex following finger tapping tasks. These data were processed using partial least squares-discriminant analysis (PLS-DA) to develop a prediction model for a brain-computer interface. The tasks were composed of a series of finger tapping for 15 sec and relaxation for 45 sec. The location of the motor cortex was confirmed by the anti-phasic behavior of the oxy- and deoxy-hemoglobin changes. The results were compared with those obtained using the hidden Markov model (HMM) which has been known to produce the best prediction model. Our data imply that PLS-DA makes better judgments in determining the onset of the events than HMM.

Prediction of Chemical Compositions for On-line Quality Measurement of Red Pepper Powder Using Near Infrared Reflectance Spectroscopy (NIRS)

  • Lee, Sun-Mee;Kim, Su-Na;Park, Jae-Bok;Hwang, In-Kyeong
    • Food Science and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.280-285
    • /
    • 2005
  • Applicability of near infrared reflectance spectroscopy (NIRS) was examined for quality control of red pepper powder in milling factories. Prediction of chemical composition was performed using modified partial least square (MPLS) techniques. Analysis of total 51 and 21 red pepper powder samples by conventional methods for calibration and validation, respectively, revealed standard error of prediction (SEP) and correlation coefficient ($R^2$) of moisture content, ASTA color value, capsaicinoid content, and total sugar content were 0.55 and 0.90, 8.58 and 0.96, 31.60 and 0.65, and 1.82 and 0.86, respectively; SEP and $R^2$ were low and high, respectively, except for capsaicinoid content. The results indicate, with slight improvement, on-line quality measurement of red pepper powder with NIRS could be applied in red pepper milling factories.

근적외선 분광분석을 통한 산무수물경화 에폭시 시스템의 경화 동력학 (Cure Kinetics for the Acid Anhydride-cured Epoxy System Using a Near-infrared Reflection Spectroscopy)

  • 곽근호;박수진;이재락
    • 폴리머
    • /
    • 제24권1호
    • /
    • pp.65-71
    • /
    • 2000
  • 산무수물 경화 에폭시 수지의 잠재 특성 및 경화 동력학을 근적외선 분광분석법을 통해서 논의하였다. 잠재 특성과 경화 거동의 확인은 각기 다른 온도에서 에폭사이드와 수산기의 NIR reflectance를 측정함으로써 행해졌으며 반응 과정에서 4000~7100$cm^{-1}$ / 스펙트럼 범위의 주된 NIR 흡수피크의 기점, 위치 그리고 전이에 대한 포괄적인 분석이 이루어졌다. 반응의 정도는 에폭사이드의 함량과 경화 온도에 의존적인 4530$cm^{-1}$ /의 NIR 흡수 피크로부터 결정하였다.

  • PDF

근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석 (Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • 약학회지
    • /
    • 제48권1호
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Application for Measuring the Glucose, Ammonia nitrogen, and Tylosin Concentration using Near Infrared Spectroscopy

  • Kim, Jong-Soo;Cho, Hoon
    • 환경위생공학
    • /
    • 제23권2호
    • /
    • pp.19-25
    • /
    • 2008
  • For measurement of tylosin, ammonia nitrogen, and glucose concentration during the culture of Streptomyces fradiae using Near Infrared Spectroscopy, the calibration using various mathematical models was performed and then, based on the linear model, the validation was carried out. In the case of sucrose concentration using the MLR method, the Standard Error of Prediction and Multiple correlation coefficient were 1.97, and 0.991, respectively. In the case of ammonia nitrogen concentration using the PLSR method, the Standard Error of Prediction and Multiple correlation coefficient were 0.13, and 0.990, respectively. In the case of tylosin concentration using the PLSR method, the standard Error of Prediction and Multiple correlation coefficient were 0.54, and 0.984, respectively.

Surgical Treatment of an Innominate Artery Aneurysm Using Near-Infrared Spectroscopy for Cerebral Monitoring: A Case Report

  • Jeon, Byeng Hun;Lee, Chul Ho;Bae, Chi Hoon;Jang, Jae Seok;Cho, Jun Woo
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.517-520
    • /
    • 2021
  • Innominate artery aneurysms are challenging for surgeons to treat because of the requirement for brain protection during surgery. In innominate artery aneurysms, the endovascular approach does not require cardiopulmonary bypass, but patients who can be treated using this approach are limited in number, and the long-term results of endovascular treatment are unclear. Here, we report our experience of successfully treating a patient with an innominate artery aneurysm using near-infrared spectroscopy without cardiopulmonary bypass support or hypothermic circulatory arrest.

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons by Near Infrared Spectroscopy using a Partial Least Squares Regression

  • Nam, Jae-Jak;Lee, Sang-Hak;Park, Ju-Eun
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1276-1276
    • /
    • 2001
  • Polycyclic aromatic hydrocarbons(PAHs) are widely distributed in the environment and are often implicated as potential carcinogens. The chromatographic methods of detection and quantitative determination of PAHs in environmental samples are costly, time consuming, and do not account for all kinds of PAHs. This work describes a quantitative spectroscopic method for the analysis of mixtures of eight PAHs using multivariate calibration models for Fourier transform near infrared(FT-NIR) spectral data. The NIR spectra of mixtures of PAHs (anthracene, pyrene, 1,2-benzanthracene, perylene, chrysene, benzo(a)pyrene, 1-methylanthracene and benzo(ghi)perylene) were measured in the wavelength range from 1100 nm to 2500 nm. The spectral data were processed using a partial least squares regression. We have studied the spectral characteristics of NIR spectra of mixtures of PAHs. It was possible to determine each PAM used in this study at the environmental level(mg L-1) in the laboratory samples. Further development may lead to the rapid determination of more PAHs in typical environmental samples.

  • PDF

Self-Modeling Curve Resolution Analysis of On-line Near Infrared Spectra Measured during the Melt-Extrusion Transesterification of Ethylene/Vinylacetate Copolymer

  • Sasic, Slobodan;Kita, Yasuo;Furukawa, Tsuyoshi;Watari, Masahiro;Siesler, Heinz W.;Ozaki, Yukihiro
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1284-1284
    • /
    • 2001
  • The transesterification of molten ethylene/vinylacetate (EVA) copolymers by octanol as a reagent and sodium methoxide as a catalyst in an extruder has been monitored by on-line near infrared (NIR) spectroscopy. A total of 60 NIR spectra were acquired for 37 minutes with the last spectrum recorded 31 minutes after the addition of octanol and catalyst was stopped. The experimental spectra show strong baseline fluctuations which are corrected for by multiplicative scatter correction (MSC). The chemometric methods of orthogonal projection approach (OPA) and multivariate curve resolution (MCR) were used to resolve the spectra and to derive concentration profiles of the species. The detailed analysis reveals the absence of completely pure variables that leads to small errors in the calculation of pure spectra. The initial estimation of a concentration that is necessary as an input parameter for MCR also presents a non-trivial task. We obtained results that were not ideal but applicable for practical concentration control. They enable a fast monitoring of the process in real-time and resolve the spectra of the EVA copolymer and the ethylene/vinyl alcohol (EVAL) copolymer to be very close to the reference spectra. The chemometric methods used and the decomposed spectra are discussed in detail.

  • PDF

MONITORING THE EFFECT OF THE ULTRA-HIGH PRESSURE PRESERVATION TECHNOLOGY BY NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Kaffka, Karoly J.;Farkas, Jozsef;Seregely, Zsolt;Meszaros, Laszlo
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.2122-2122
    • /
    • 2001
  • The ultra-high pressure technology fur the preservation of foods is under intense research to evaluate its potential as an alternative or complementary process to traditional methods of food preservation. Traditional processing methods usually need a large amount of energy, may cause unwanted reactions in the food, leading to cooked flavor and loss of vitamins, etc. The application of ultra-high hydrostatic pressure for food processing consists of subjecting the food to pressures in the range of 100-1000 ㎫. The ultra-high pressure inactivates the microorganisms and some enzymes, promotes the germination of spores and extends the shelf-life of the foods. This new technology follows the “minimal processing” concept minimizing the quality degradation, saving the vitamins, essential nutrients and flavors as well as utilizing less energy. We joined the research team at our University involved in the mentioned technology using an ultra-high pressure equipment, recording of the near infrared spectra and signal response of a chemosensor array (electronic nose) of their meat (beef and pork), vegetable and fruit samples exposed to different pressure. The results of our investigations achieved by evaluating the measured data using PCA and PQS methods will be presented.

  • PDF