• 제목/요약/키워드: Spectral imaging

검색결과 391건 처리시간 0.032초

DEVELOPMENT OF QUALITY EVALUATION SYSTEM FOR PEANUT WITH POD USING OPTICAL METHODS

  • Morta, Kazuo;Taharazako, Shoji;Zhang, Han;Maekaji, Kenji;Ikeda, Hirohiko
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.1354-1363
    • /
    • 1993
  • Optical methods were developed to examine their feasibility for quality evaluation of peanut with pod. Surface color and internal quality of peanut were measured without contact. The surface color of peanut was measured by light reflectance at a region of visible wavelengths. Its characteristic was high correlated with a visual grading of peanut. A trial machine for the color grading of peanut was developed using an optical sensor and it was considered to compare with the visual grading. The spectral reflectance at a region of near infrared wavelengths from 1,200 to 2,500nm was measured , and the chemical components of peanut were related to spectral reflectance at special wavelengths. The protein, fat and moisture contents of peanut were estimated by the near infrared methods. An infrared imaging method was developed to evaluate the internal quality of peanut with pod. As thermal characteristic of peanut with pod was deeply related to internal quality , the quality of peanut can be evaluated by temperature changes on the surface of peanut. Measurement of surface color, near infrared reflectance and thermal imaging were shown to be very effective in grading of peanut with pod.

  • PDF

In Situ Single Cell Monitoring by Isocyanide-Functionalized Ag and Au Nanoprobe-Based Raman Spectroscopy

  • Lee, So-Yeong;Jang, Soo-Hwa;Cho, Myung-Haing;Kim, Young-Min;Cho, Keun-Chang;Ryu, Pan Dong;Gong, Myoung-Seon;Joo, Sang-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권9호
    • /
    • pp.904-910
    • /
    • 2009
  • The development of effective cellular imaging requires a specific labeling method for targeting, tracking, and monitoring cellular/molecular events in the living organism. For this purpose, we studied the cellular uptake of isocyanide-functionalized silver and gold nanoparticles by surface-enhanced Raman scattering (SERS). Inside a single mammalian cell, we could monitor the intracellular behavior of such nanoparticles by measuring the SERS spectra. The NC stretching band appeared clearly at ${\sim}2,100cm^{-1}$ in the well-isolated spectral region from many organic constituents between 300 and 1,700 or 2,800 and $3,600cm^{-1}$. The SERS marker band at ${\sim}2,100cm^{-1}$ could be used to judge the location of the isocyanide-functionalized nanoparticles inside the cell without much spectral interference from other cellular constituents. Our results demonstrate that isocyanide-modified silver or gold nanoparticle-based SERS may have high potential for monitoring and imaging the biological processes at the single cell level.

이중대역 적외선 검출기를 이용한 적외선 카메라 설계 (Design of an Infrared Camera using a Dual-band Infrared Detector)

  • 박진호;김홍락;김경일;이다빈
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.93-97
    • /
    • 2022
  • 적외선 영상은 온도 정보뿐만 아니라 파장 정보를 포함하고 있으며 이는 단일 파장의 적외선 카메라로는 분석이 불가능하다. 다중 파장 적외선 카메라는 적외선 영상에 포함된 광범위한 정보를 획득할 수 있다. 다중 파장 적외선 카메라의 한 종류인 이중대역 적외선 카메라는 시스템 구성을 쉽게 할 수 있다는 이점이 있다. 이중대역 적외선 카메라는 적외선 영상에 포함된 온도정보 뿐만 아니라 파장 정보를 획득할 수 있고 이를 통해 적외선 카메라의 탐지/식별 성능을 향상시킬 수 있다. 본 논문에서는 중적외선 대역과 원적외선 대역을 동시에 획득할 수 있는 이중대역 적외선 검출기를 이용한 적외선 카메라의 설계에 대하여 기술한다.

Study on the First On-Orbit Solar Calibration Measurement of Ocean Scanning Multi-spectral Imager (OSMI)

  • Cho, Young-Min
    • Journal of the Optical Society of Korea
    • /
    • 제5권1호
    • /
    • pp.9-15
    • /
    • 2001
  • The ocean Scanning Multi-spectral Imager (OSMI) is a payload on the KOrea Multi-Purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring f the study of biological oceanography. OSMI performs solar and dark calibrations for on-orbit instrument calibration. The purpose of the solar calibration is to monitor the degradation of imaging performance for each pixel of 6 spectral bands and to correct the degradation effect on OSMI image during the ground station date processing. The design, the operation concept, and the radiometric characteristics of the solar calibration are investigated. A linear model of image response and a solar calibration radiance model are proposed to study the instrument characteristics using the solar calibration data. The performance of spectral responsivity and spatial response uniformity. The first solar calibration data and the analysis results are important references for further study on the on-orbit stability of OSMI response during its lifetime.

SUBARU EXPLORATIONS OF EXO-SOLAR PLANETS AND DISKS

  • TAMURA MOTOHIDE
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.319-324
    • /
    • 2005
  • To date, more than 150 exo-solar planets have been observed by various methods such as spectroscopic, photometric, astrometric, gravitational lensing, pulsar timing methods. However, all these are indirect methods; they do not directly image the planets. Only free-floating planets or their 'ana-log' have been directly detected so far. Thus the next milestone is the direct imaging of any kinds of planetary mass objects orbiting around normal (young) stars, which might have been associated with protoplanetary disks, the sites of planet formation. I will describe some SUBARU efforts to detect self-luminous young giant planets as companions as well as direct imaging of the protoplanetary disks of ${\~}$100 AU size. The results of near-infrared coronagraphic imaging with adaptive optics are briefly presented on AB Aur, HD 142527, T Tau, and DH Tau. Our results demonstrate the importance of high-resolution (${\~}$0.1 arcsec) direct imaging over indirect observations such as modeling based on spectral energy distributions. The SUBARU observations are a prelude to ALMA from the morphological point of view.

Contrast-Enhanced Spectral Mammography Versus Ultrasonography: Diagnostic Performance in Symptomatic Patients with Dense Breasts

  • Zhongfei Lu;Cuijuan Hao;Yan Pan;Ning Mao;Xin Wang;Xundi Yin
    • Korean Journal of Radiology
    • /
    • 제21권4호
    • /
    • pp.442-449
    • /
    • 2020
  • Objective: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard. Materials and Methods: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained. Results: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US. Conclusion: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.

Modis Maximum NDVI, Minimum Blue, and Average Cloud-free Monthly Composites of Southeast Asia

  • Zerbe, L.;Chia, A.S.;Liew, S.C.;Kwoh, L.K.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.172-174
    • /
    • 2003
  • Using MODIS data and several different compositing algorithms utilizing the average cloud free days in a compositing period, maximum ndvi, or dual maximum NDVI/minimum blue, multi resolution composites (250m, 500m, 1km) have been produced for Southeast Asia, with spectral bands ranging from the visible to short-wave infrared with a single band in the thermal (for land and sea surface temperature). A total of nine composites have been produced for the months of May and August in 2003, including blue, green, red, NIR, three in the SWIR, and several to specifically monitor vegetation health.

  • PDF

Radiomics in Breast Imaging from Techniques to Clinical Applications: A Review

  • Seung-Hak Lee;Hyunjin Park;Eun Sook Ko
    • Korean Journal of Radiology
    • /
    • 제21권7호
    • /
    • pp.779-792
    • /
    • 2020
  • Recent advances in computer technology have generated a new area of research known as radiomics. Radiomics is defined as the high throughput extraction and analysis of quantitative features from imaging data. Radiomic features provide information on the gray-scale patterns, inter-pixel relationships, as well as shape and spectral properties of radiological images. Moreover, these features can be used to develop computational models that may serve as a tool for personalized diagnosis and treatment guidance. Although radiomics is becoming popular and widely used in oncology, many problems such as overfitting and reproducibility issues remain unresolved. In this review, we will outline the steps of radiomics used for oncology, specifically addressing applications for breast cancer patients and focusing on technical issues.