• Title/Summary/Keyword: Spectral Contrast

Search Result 164, Processing Time 0.021 seconds

The Classification of Music Styles on the Basis of Spectral Contrast Features

  • Wang, Yan-bing
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • In this paper, we propose that the contrast features of octave spectrum can be used to show spectral contrast features of some music clips. It shows the relative spectral distribution rather than average spectrum. From the experiment, it can be seen the method of spectral contrast features has a good performance in classification of music styles. Another comparative experiment shows that the method of spectral contrast features can better distinguish different music styles than the method of MFCC features that commonly used previously in the classification system of music styles.

Study on the Performance of Spectral Contrast MFCC for Musical Genre Classification (스펙트럼 대비 MFCC 특징의 음악 장르 분류 성능 분석)

  • Seo, Jin-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.265-269
    • /
    • 2010
  • This paper proposes a novel spectral audio feature, spectral contrast MFCC (SCMFCC), and studies its performance on the musical genre classification. For a successful musical genre classifier, extracting features that allow direct access to the relevant genre-specific information is crucial. In this regard, the features based on the spectral contrast, which represents the relative distribution of the harmonic and non-harmonic components, have received increased attention. The proposed SCMFCC feature utilizes the spectral contrst on the mel-frequency cepstrum and thus conforms the conventional MFCC in a way more relevant for musical genre classification. By performing classification test on the widely used music DB, we compare the performance of the proposed feature with that of the previous ones.

Virtual Non-Contrast Computer Tomography (CT) with Spectral CT as an Alternative to Conventional Unenhanced CT in the Assessment of Gastric Cancer

  • Tian, Shi-Feng;Liu, Ai-Lian;Wang, He-Qing;Liu, Jing-Hong;Sun, Mei-Yu;Liu, Yi-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2521-2526
    • /
    • 2015
  • Objective: The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Materials and Methods: Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Results: Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, $p{\leq}0.008$). Carcinoma-perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, p< 0.001). There were no significant differences of carcinoma-water CNR and carcinoma-perigastric fat CNR among VNCa, VNCv, and VNCe images. There was no difference in the determination of invasion or enlarged lymph nodes between normal CT and VNCa images. Conclusions: VNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

Research on the Technology of Alternative Continuous Wide Spectral Spatial Heterodyne Spectrometer

  • Zhang, Wenli;Tian, Fengchun;Zhao, Zhenzhen;Song, An;Zhang, Li
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.295-307
    • /
    • 2017
  • An innovative system for the alternative continuous wide spectral spatial heterodyne spectrometer (ACWS-SHS) is proposed. The relationship between the ACWS-SHS and the wide spectral spatial heterodyne spectrometer (WS-SHS) at the resolution limit, the spectral range, the grating diffraction efficiency and the interference fringes contrast ratio has been analyzed theoretically. Through the comparison of the theoretical analysis and simulation results, it is found that the two systems for the WS-SHS and the ACWS-SHS have the same resolution limit and spectral range, which are ${\delta}{\sigma}$ and ${\sigma}_{01}$, while in the ACWS-SHS system the critical diffraction efficiency of echelle grating is 68.39% and the critical contrast ratio of interference fringes is 0.4135, which is much better than the performance of the WS-SHS system. Therefore, the ACWS-SHS reduces the high requirements for the precision of equipment and expands the application field of SHS effectively.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Study on the dynamic behaviors of curved beam structure using spectral element (스펙트럴 요소를 이용한 곡선 보 구조물의 동적거동 해석)

  • 이준근;이우식;박철희
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.83-88
    • /
    • 1996
  • The significance of spectral element method is that it can treat the mass and stiffness distribution exactly in contrast to the conventional finite element method, and therefore the dynamic behaviors within each spectral element can be obtained exactly. The present study provides the derivation of the spectral element of a curved beam, while the previous ones presented that of a straight structure. Further, in order to verify the derived spectral element, the natural frequencies of a ring by the spectral element method are compared with those by the analytical method and those by the FEM. From the verification, derived spectral element is admissible. And the dynamic behaviors of curved beam are simulated by using the derived spectral element of a curved beam.

  • PDF

SPECTRAL SENSITIZATION AND PHOTOGRAPHIC CHARACTERISTICS OF NAPHTHOTHIAZOLO CARBOCYANINE DYE

  • Kim, Yeoung-Chan
    • Journal of Photoscience
    • /
    • v.3 no.2
    • /
    • pp.65-69
    • /
    • 1996
  • In this paper, it was studied about the red-sensitive layer. UV-Vis data of the dye at monomeric and J-state were considered with respect to their performance(contrast, density and fog) in photographic emulsion. The sensitizing effect of the dye is found to be strongly structuredependent. Naphthothiazolo carbocyanine dye can be used as red-sensitizing dye for the spectral sensitization of photographic emulsion.

  • PDF

Spectral Sensitization and Photographic Characteristics of 9-Phenyl-3,3'-Bis(3-Sulfopropyl)-4,5,4',5'-Naphthothiazolo Carbocyanine Triethyl Ammonium Salt

  • Kim, Yeoung-Chan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.366-371
    • /
    • 2003
  • In this paper, it was studied about the red-sensitive layer. UV-Vis data of the dye at monomeric and J-state were considered with respect to their performance(contrast, speed, density and fog) in photographic emulsion. The sensitizing effect of the dye is found to be strongly structure-dependent. Naphthctbiazolo carbocyanine dye can be used as red sensitizing dye for the spectral sensitization of photographic emulsion.

A SIMPLE GRANULE MODEL AND ITS EFFECT ON SPECTRAL LINE ASYMMETRY

  • KIM YONGCHEOL
    • Journal of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.77-87
    • /
    • 1998
  • The accumulated knowledge of the influence of solar granulation on spectral lines, i.e. their asymmetry, provides a key to analyze stellar spectral line asymmetries. In this paper, a simple line synthesis using a simple 'model' of granulation was calculated. By adjusting the properties of the granule model, the observed imprints of convection on spectral lines can be reproduced. Since we depict convective flows using a continuous function rather than using a few components of flows (cf. Gray and Toner 1985, 1986; dravins 1990), we were able to identify which components of convection are important in line bisector shapes. The results of this study can be summarized as follows: Firstly, the intensity contrast (i.e. temperature fluctuation), and the area coverage of up- and down-flows are the two important factors which determine the line bisector shapes. Secondly, on the contrary to the assumption of other studies, the effect of horizontal flows is non-negligible. This exercise provides a qualitative understanding of the effect of convection on spectral lines. This knowledge serves as a guideline for understanding the characteristic difference in convection for stars on either side of the 'Granulation Boundary' (Gray 1982; Gray and Nagel 1989).

  • PDF

Spectrally Phase Coded Waveform Discrimination at 10 GHz for Narrow Band Optical CDMA within 100 GHz Spectral Window

  • Seo, Dong-Sun;Supradeepa, V.R.
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.28-32
    • /
    • 2010
  • We demonstrate binary spectral phase coded waveform discrimination at 10 GHz for narrow band optical code-division multiple-access (NB-OCDMA) via direct electrical detection without using any optical hard-limiter. Only 9 phase-locked, 10 GHz spaced, spectral lines within a 100 GHz spectral window are used for the phase coding. Considerably high contrast ratio of 5 between signal and multiuser access interference noise can be achieved for $4{\times}10\;G\;pulse/sec$ timing coordinated OCDMA at a simple electrical receiver with 50 GHz bandwidth.