• Title/Summary/Keyword: Speckle effect

Search Result 48, Processing Time 0.025 seconds

Speckle Reduction in Near-field Image of Multimode Fiber with a Piezoelectric Transducer

  • Ha, Woo-Sung;Lee, Se-Jin;Oh, Kyung-Hwan;Jung, Yong-Min;Kim, Jun-Ki
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.126-130
    • /
    • 2008
  • We propose and experimentally demonstrate an effective method to reduce near-field speckle noise at the output of a 50 ${\mu}m$ graded index multimode fiber using a short cylindrical piezoelectric transducer(PZT) vibrating in the radial direction. The fiber was coiled as tightly as possible around the mandrel of the PZT and a periodic stretching effect was caused by the radial oscillations of the actuator. The output of the optical fiber using the He-Ne laser source was intensively observed by a CCD camera. By counting all the pixels corresponding to relative intensity graded into 256 levels in the selected area and by calculating standard deviation and mean value of the intensity, we could measure the speckle contrast and vibration effect quantitatively with reduction ratio of pixels and line profile of the illuminated region. It was clearly observed that the characteristics of the speckle pattern in the vibration-on state were significantly improved over that of the vibration-off state due to time-averaged smoothing.

Filtering Effect in Supervised Classification of Polarimetric Ground Based SAR Images

  • Kang, Moon-Kyung;Kim, Kwang-Eun;Cho, Seong-Jun;Lee, Hoon-Yol;Lee, Jae-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.705-719
    • /
    • 2010
  • We investigated the speckle filtering effect in supervised classification of the C-band polarimetric Ground Based SAR image data. Wishart classification method was used for the supervised classification of the polarimetric GB-SAR image data and total of 6 kinds of speckle filters were applied before supervised classification, which are boxcar, Gaussian, Lopez, IDAN, the refined Lee, and the refined Lee sigma filters. For each filters, we changed the filtering kernel size from $3{\times}3$ to $9{\times}9$ to investigate the filtering size effect also. The refined Lee filter with the kernel size of bigger than $5{\times}5$ showed the best result for the Wishart supervised classification of polarimetric GB-SAR image data. The result also showed that the type of trees could be discriminated by Wishart supervised classification of polarimetric GB-SAR image data.

Measurement of Deformation field in CT specimen using Laser speckle (레이저 스페클을 이용한 CT 시험편의 변형장 측정)

  • Jean, Moon-Chang;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.192-197
    • /
    • 2001
  • To obtain $A_2$ experimentally in the $J-A_2$ theory, deformation field on the lateral surface of a CT specimen was to be determined using Laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure $A_2$ continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and $A_2$ were explored.

  • PDF

A Study of Measurement of In-plane Displacement by CW Laser Speckle Photography and Image Processing (연속파 레이저 스페클 사진법(寫眞法)과 화상처리(畵像處理)에 의한 면내섭위(面內燮位) 측정(測定)에 관한 연구(硏究))

  • Kim, K.S.;Na, G.D.;Kim, T.H.;Chung, N.K.;Kim, C.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.47-55
    • /
    • 1990
  • This paper presents experimental results which explore the capability of a CW laser speckle photography for tile measurement of in-plane displacement at high temperature. The serious restrictions on the application of the method seem to be the ambient air turbulence and the change of surface texture caused by the oxidation, as they tend to decorrelate the double exposured speckle patterns. In order to assess only the effect of air turbulence, a ceramics-coated stainless steel plate is heated in air and Ar-laser specklegrams are made with combination of temperature and lateral translation displacement. The slight reduction in visibility of Young's fringes is observed at $1000^{\circ}C$. The analyses of Young's fringes are carried out by a image processing system using a TV-camera and computers, and the result agrees well with the micrometer reading. Futhermore, uncoated stainless steel and Hastelloy X plates are tested and the effect of oxidation is also evaluated. The experimental results demonstrate that a CW laser speckle photography is applicable at temperatures up to $1000^{\circ}C$.

  • PDF

The Effect of the DIC Speckle Patterns for a Microcrack Measurement (미소균열 측정에 대한 DIC 스펙클 형상의 영향)

  • Lee, Jun Hyuk;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.15-21
    • /
    • 2019
  • In order to secure the safety of various machinery, it is very important to develop a technique for accurately and quickly measuring the cracks generated in the mechanical equipment and evaluating the mechanical characteristics. The evaluation of the mechanical properties is accompanied by an appropriate strain measurement according to the material and crack occurrence of the target structure. Especially, when micro cracks are generated, the evaluation method is very important. Digital image correlation is an optical full field displacement measuring method which is using currently with speckles in the interested area. However the evaluation method and conditions of image distributions have to be considered carefully to measure the crack occurrence because the images of the speckle patterns affect the quality of displacement results. In this study, the speckle pattern density is characterized to improve the accuracy of the measurement method. And also the micro crack initiation is detected by the measured displacement in the adopted speckle pattern distribution. It is shown that the proposed method is useful to determine the density pattern distribution for the accurate measurement and crack detection.

Study of Monitoring Parameters for Coherent Beam Combination through Fourier-domain Analysis of the Speckle Image (스펙클 이미지의 푸리에 공간 분석을 통한 결맞음 빔결합 상태 모니터링 변수 도출)

  • Park, Jaedeok;Choe, Yunjin;Yeom, Dong-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.268-273
    • /
    • 2020
  • We analyze the characteristics of the coherent beam combination of lasers by monitoring the speckle pattern of the beam reflected from a scattering medium. Three collimated laser sources with high coherence are focused on a scattering target using a lens, and we then examine the speckle pattern of the returned beam in the Fourier domain. We observe that the size of the speckle pattern changes, depending on the focused-beam size or degree of spatial overlap of the three beams. Furthermore, through Fourier-domain analysis of the speckle pattern we obtain the monitoring variable to qualify the efficiency of the coherent beam combination.

Improvement of Contour Fringes by using Addition of Incremental Images (화상 증분 축적법을 이용한 등고선 간섭무늬의 개선)

  • Kang, Young-June;Kim, Gye-Sung;Ryu, Weon-Jae;Kwon, Yong-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.12
    • /
    • pp.190-197
    • /
    • 1999
  • Electronic speckle contouring(ESC) is the optical method for measuring shape by using fringe-projection techniques in electronic speckle pattern interferometry. It has the advantage of being non-contacting and can also give a field view of the surface under investigation. Fringes in ESC represent the difference in depth along the view direction between the master wavefront and the test component. The contour maps of three-dimensional diffuse objects are obtained by small shifts of optical fiber carrying the dual-object-beams and 4-frame phase shift. We proposed the contouring method by shifting the collimated illumination beams through optical fiber in order to obtain the contour fringe patterns. And also, we performed addition of incremental addition of images and experiments based on it. we obtained both quantitative increment without decorrelation effect and qualitative improvement by reducing the noise of contour fringes.

  • PDF

Improvement of Contour Fringes by using Addition of Incremental Images

  • Kang, Young-June;Ryu, Weon-Jae;Park, Sang-Kyu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.37-43
    • /
    • 2002
  • Electronic speckle contouring(ESC) based on electronic speckle pattern interferometry is the optical method for measuring object shape by using fringe-projection techniques. This method has the advantages of being non-contact, non-destructive and a whole-field measurement of the surface under investigation. Fringes in ESC represent the difference in depth along the view direction between the master wavefront and the test component. The contour maps of three-dimensional diffuse objects can be obtained by small shifts of optical fiber carrying the dual-object-beams and 4-frame phase shifting. In this study we proposed the contouring method by shifting the collimated illumination beams through optical fiber in order to obtain the contour fringe patterns. And also, we performed the addition of incremental images through the geometrical analysis to obtain the contour fringe interval when we performed the incremental addition of images and experiments based on this method. We obtained both quantitative increment without decorrelation effect and qualitative improvement by reducing the noise of contour fringes.

RESIDUAL STRESS MEASUREMENT ON THE BUTT-WELDED AREA BY ELECTRONIC SPECKLE PATTERN INTERFEROMETRY

  • KIM, KYEONGSUK;CHOI, TAEHO;NA, MAN GYUN;JUNG, HYUNCHUL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.115-125
    • /
    • 2015
  • Background: Residual stress always exists on any kind of welded area. This residual stress can cause the welded material to crack or fracture. For many years, the hole-drilling method has been widely used for measuring residual stress. However, this method is destructive. Nowadays, electronic speckle pattern interferometry (ESPI) can be used to measure residual stress with or without the hole-drilling method. ESPI is an optical nondestructive testing methods that use the speckle effect. Mechanical properties can be measured by calculation of the phase difference by the variation of temperature, pressure, or loading force. Methods: In this paper, the residual stress on the butt-welded area is measured by using ESPI with a suggested numerical calculation. Two types of specimens are prepared. Type I is made of pure base metal part and type II has a welded part at the center. These specimens are tensile tested with a material test system. At the same time, the ESPI system was applied to this test. Results: From the results of ESPI, the elastic modulus and the residual stress around the welded area can be calculated and estimated. Conclusion: With this result, it is confirmed that the residual stress on the welded area can be measured with high precision by ESPI.

Two-dimensional speckle-tracking of antral contraction in dogs

  • Park, Junghyun;An, Soyon;Hwang, Tae Sung;Lee, Hee Chun
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.2
    • /
    • pp.55-59
    • /
    • 2020
  • This study was purposed to make the referenced range of stomach antral contraction strain in 50 dogs using 2-dimensional speckle tracking. In addition, the strain results were compared among body condition scores to reveal the correlations of obesity among the subjects of the study. Finally, the medetomidine group that was comprised of 10 dogs was compared with the normal group to identify the medetomidine pharmacologic effect in the stomach antral contraction. Clinically healthy 50 dogs were recruited for the study. In an ultrasonographic examination, the stomach antrum region was scanned, and at least one cycle of antral contraction was recorded. The peak strain of antral contraction in healthy dogs was 58.2 ± 20.47% (mean ± SD). The obesity group showed a high strain result and there were significant correlations between the body condition score (BCS) 2, BCS 3 groups and BCS 8 group. The medetomidine group revealed a low strain result and was significantly correlated with normal group. Two-dimensional speckle tracking was useful to the evaluation of stomach motility disorders.