• Title/Summary/Keyword: Specimens

Search Result 17,198, Processing Time 0.035 seconds

A Study on the Evaluation of the Friction and Wear Properties of the Sprayed Coating Layer (용사피막의 마찰.마모 특성 평가에 관한 연구)

  • 김영식;김윤해;김종호;최영국;강태영
    • Journal of Welding and Joining
    • /
    • v.14 no.3
    • /
    • pp.66-74
    • /
    • 1996
  • In this study, friction and wear properties of flame sprayed specimens and hard Cr plating specimens were tested, and their properties were compared each other in dry and lubrication condition. Ni-Cr powder and steel powder were used as the spray powder and sprayed on the steel(S45C) substrate by flame sprayed method. Each wear surface was observed with SEM after friction and wear test. The friction coefficient of the as-forged steel specimens was the highest among surface treatment specimens, and the other specimens appeared in order as follows ; hard Cr-plating specimens, Ni-Cr powder sprayed specimens, steel powder sprayed specimens. Comparing the wear volumes in dry condition, as forged steel specimens appeared the greatest wear volume, and the other specimens appeared wear volume in order as follows ; Ni-Cr powder sprayed specimens, steel powder sprayed specimens, hard Cr plating specimens. In friction and wear test, the hard Cr plating specimens were worn by the abrasive phenomenon, involving the cracks. The wear volume of steel powder sprayed specimens was lower than that of Ni-Cr powder sprayed specimens. Comparing the tensile strength of both sprayed coating layers, the steel powder sprayed coating layer was better than Ni-Cr powder sprayed coating layer.

  • PDF

Influence of Compressive Strength of Concrete Affected by fixed test Specimens and moved test Specimens (운반된 공시체가 콘크리트의 압축강도에 미치는 영향)

  • 조일호;양재성;김성욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.957-960
    • /
    • 2000
  • The purpose of this study was performed to estimate the influence of compressive strength of the concrete according to change test specimens of concrete were investigated by measurements of slump, air content and compressive strength. As a result, according to moved test specimens, the compressive strength, fiexed test specimens effected on Concrete compressive strength, test specimens than moved test specimens, increased 4∼10% fixed test specimens, 2∼9% moved test specimens.

Performance of FRP confined and unconfined geopolymer concrete exposed to sulfate attacks

  • Alzeebaree, Radhwan;Gulsan, Mehmet Eren;Nis, Anil;Mohammedameen, Alaa;Cevik, Abdulkadir
    • Steel and Composite Structures
    • /
    • v.29 no.2
    • /
    • pp.201-218
    • /
    • 2018
  • In this study, the effects of magnesium sulfate on the mechanical performance and the durability of confined and unconfined geopolymer concrete (GPC) specimens were investigated. The carbon and basalt fiber reinforced polymer (FRP) fabrics with 1-layer and 3-layers were used to evaluate the performances of the specimens under static and cyclic loading in the ambient and magnesium sulfate environments. In addition, the use of FRP materials as a rehabilitation technique was also studied. For the geopolymerization process of GPC specimens, the alkaline activator has selected a mixture of sodium silicate solution ($Na_2SiO_3$) and sodium hydroxide solution (NaOH) with a ratio ($Na_2SiO_3/NaOH$) of 2.5. In addition to GPC specimens, an ordinary concrete (NC) specimens were also produced as a reference specimens and some of the GPC and NC specimens were immersed in 5% magnesium sulfate solutions. The mechanical performance and the durability of the specimens were evaluated by visual appearance, weight change, static and cyclic loading, and failure modes of the specimens under magnesium sulfate and ambient environments. In addition, the microscopic changes of the specimens due to sulfate attack were also assessed by scanning electron microscopy (SEM) to understand the macroscale behavior of the specimens. Results indicated that geopolymer specimens produced with nano-silica and fly ash showed superior performance than the NC specimens in the sulfate environment. In addition, confined specimens with FRP fabrics significantly improved the compressive strength, ductility and durability resistance of the specimens and the improvement was found higher with the increased number of FRP layers. Specimens wrapped with carbon FRP fabrics showed better mechanical performance and durability properties than the specimens wrapped with basalt FRP fabrics. Both FRP materials can be used as a rehabilitation material in the sulfate environment.

AN EXPERIMENTAL STUDY ON BOND STRENGTH OF SILICOATED RESIN BONDED RESTORATION (Silicoating이 수지접합 수복물의 결합력에 미치는 영향에 관한 실험적 연구)

  • Shin, Hyeon-Soo;Han, Dong-Hu;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.101-121
    • /
    • 1989
  • This study investigated the effects of Silicoating procedure on the tensile bond strength of resin-bonded prostheses. The Rexillium III specimens were treated with electrochemical etching and Silicoating procedure, followed by thermocycling and the NNB, Pors-on 4, and Degudent-U specimens were treated with Silicoating procedure. The specimens were debonded in tension with a Tensilon machine. Also, all specimens were observed with SEM, concentration of Si elements was analyzed with EPMA, and the mode of failure was recorded. The results of this study were obtained as follows: 1. In the Rexillium III specimens, the tensile bond strength of the Silicoated specimens was higher than that of the electrochemically etched specimens, and significant differences were observed (P<0.05). 2. The tensile bond strength of electrochemically etched Rexillium III specimens, significant differences were observed between the thermocycled and nonthermocycled specimens (P<0.05), but no significant differences were observed in the Silicoated specimens (P>0.05). 3. The tensile bond strength of the Silicoated specimens decreased NNB, Pors-on 4, Rexillium III, and Degudent-U in that order named. 4. Unlike the electrochemically etched specimens, the Silicoated specimens showed gap-free metal-resin interfaces with SEM. 5. Compared to the electrochemically etched specimens, the Silicoated specimens showed higher concentration of Si elements at the metal-resin interfaces and resin cement. 6. Photographic evaluation (X2) of the fractured sites revealed mainly cohesive failures with the Silicoated specimens, and adhesive failures with the electrochemically etched specimens.

  • PDF

Effects of sulphuric acid on mechanical and durability properties of ECC confined by FRP fabrics

  • Gulsan, Mehmet Eren;Mohammedameen, Alaa;Sahmaran, Mustafa;Nis, Anil;Alzeebaree, Radhwan;Cevik, Abdulkadir
    • Advances in concrete construction
    • /
    • v.6 no.2
    • /
    • pp.199-220
    • /
    • 2018
  • In this study, the effects of sulphuric acid on the mechanical performance and the durability of Engineered Cementitious Composites (ECC) specimens were investigated. The carbon fiber reinforced polymer (CFRP) and basalt fiber reinforced polymer (BFRP) fabrics were used to evaluate the performances of the confined and unconfined ECC specimens under static and cyclic loading in the acidic environment. In addition, the use of CFRP and BFRP fabrics as a rehabilitation technique was also studied for the specimens exposed to the sulphuric acid environment. The polyvinyl alcohol (PVA) fiber with a fraction of 2% was used in the research. Two different PVA-ECC concretes were produced using low lime fly ash (LCFA) and high lime fly ash (HCFA) with the fly ash-to-OPC ratio of 1.2. Unwrapped PVA-ECC specimens were also produced as a reference concrete and all concrete specimens were continuously immersed in 5% sulphuric acid solution ($H_2SO_4$). The mechanical performance and the durability of specimens were evaluated by means of the visual inspection, weight change, static and cyclic loading, and failure mode. In addition, microscopic changes of the PVA-ECC specimens due to sulphuric acid attack were also assessed using scanning electron microscopy (SEM) to understand the macroscale behavior of the specimens. Results indicated that PVA-ECC specimens produced with low lime fly ash (LCFA) showed superior performance than the specimens produced with high lime fly ash (HCFA) in the acidic environment. In addition, confinement of ECC specimens with BFRP and CFRP fabrics significantly improved compressive strength, ductility, and durability of the specimens. PVA-ECC specimens wrapped with carbon FRP fabric showed better mechanical performance and durability properties than the specimens wrapped with basalt FRP fabric. Both FRP materials can be used as a rehabilitation material in the acidic environment.

EFFECT OF THERMOCYCLING ON BONDING OF COMPOSITE RESIN AFTER DENTIN SURFACE TREATMENTS (상아질 표면처리후 복합레진 수복시 온도변화가 결합에 미치는 영향)

  • Lee, Yong-Woo;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.126-142
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of various dentin surface treatments on shear bond strength, microhardness and fracture mode before and after thermocycling. Recently extracted 75 human molars were used. The teeth were sagittal sectioned faciolingually to obtain 150 specimens. They were randomly divided into six groups. Mesial and distal dentinal surfaces of specimens were exposed by grinding and treated respectively with GC-DENTIN CONDITIONER. 10-3 solution of 4-Meta, Cleansar and Primer of GLUMA, Scotchprep of Scotchbond 2, DENTIN CONDITIONER and PRIMER A, B of ALL BOND according to the manufacturers directions. Specimens of one group were not treated. Adhesive agent of Scotchbond 2, were applied and cured on the treated dentin surfaces. After P-50 were cured on them, specimens were stored in 31c water for 24 hours before shear bond strength measurement Shear bond strength was measured in 10 specimens of each group. 10 specimens of each group were thermocycled in $20^{\circ}C$, $60^{\circ}C$,$20^{\circ}C$, $4^{\circ}C$, $20^{\circ}C$ water in order, for 30 seconds respectively, 100 times a day for 7 days. After thermocycling shear bond strength was measured. Microhardness was checked on treated dentin surface and fractured dentin surface in 10 specimens respectievly. Francture modes were observed with SEM The following results were obtained. 1. Before thermocycling. shear bond strengths in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens(P<0.01). 2. After thermocycling. shear bond strengths in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of AIL BOND were significantly higher than those in specimens not: treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta(P<0.01). Shear bond strengths in the specimens treated with GC-DENTIN CONDITIONER and PRIMER A, B of ALL BOND were significantly higher than those in other specimens except those treated with Scotchprep of Srotchbond 2(P<0.01). 3. Shear bond strengths after thermocycling were reduced in the specimens not treated, treated with GC-DENTIN CONDITIONER and 10-3 solution of 4-Meta and were increased in the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2, without significance, compared with those before thermocycling. In the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, shear bond strengths after thermocycling were significantly increased, compared with those before thermocycling(P<0.01). 4. Microhardnesses in the fractured surfaces after shear bond strength measurement were significantly increased in the specimens treated with 10-3 solution of 4-Meta and significantly decreased in the specimens treated with DENTIN CONDITIONER and PRIMER A, B of ALL BOND, compared with those in the treated dentin surfaces(P<0.01). 5. In the specimens treated with Cleanser and Primer of GLUMA, Scotchprep of Scotchbond 2 and DENTIN CONDITIONER and PRIMER A, B of ALL BOND, cohesive fracture modes were observed more than adhesive fracture modes.

  • PDF

Overview of Benign and Malignant Prostatic Disease in Pakistani Patients: A Clinical and Histopathological Perspective

  • Arshad, Huma;Ahmad, Zubair
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3005-3010
    • /
    • 2013
  • Background: To present the overall clinical and histological perspective of benign and malignant prostatic disease as seen in our practice in the Section of Histopathology, Department of Pathology and Microbiology, Aga Khan University Hospital, Karachi, Pakistan. Materials and Methods: All consecutive prostate specimens (transurethral resection or TUR, enucleation, needle biopsies) received between July 1, 2012 and December 31, 2012 were included in the study. Results: Of the total of 785 cases, 621 (79.1%) were TUR specimens, 80 (10.2%) enucleation specimens, and 84 (10.7%) needle biopsies. Some 595 (75.8%) were benign, while 190 (24.2%) were malignant. Mean weight of BPH specimens was 19 grams and 43 grams for TUR and enucleation specimens respectively. Almost 67% of adenocarcinomas were detected on TUR or enucleation specimens. Of the above cases, 41.7% were clinically benign while 58.3% were clinically malignant. The average volume of carcinoma in all cases ranged between 60 to 65%. The average number of cores involved in needle biopsies was 5. In general, higher Gleason scores were seen in TUR/enucleation specimens than in needle biopsies. Overall, in all types of specimens, commonest Gleason score was 7, seen in 74 (38.9%) cases, followed by Gleason score 9 seen in 47 (24.7%) cases. Out of the 63 needle biopsies with carcinoma, radical prostatectomy was performed in 16 cases (25.4%). Conclusions: Benign prostatic hyperplasia (BPH) is extremely common and constitutes the bulk of prostate specimens. TMajority of prostatic carcinomas are still diagnosed on TUR or enucleation specimens. These included both clinically benign and clinically malignant cases. The volume of carcinoma in these specimens was quite high indicating extensive disease. Gleason scores were also generally high compared with scores from needle biopsies. Commonest Gleason score in all type of specimens was 7. Pathologic staging was possible in very few cases since radical prostatectomies are rarely performed.

EFFECT OF COLLAGEN DISSOLUTION IN ACID CONDITIONED DENTIN ON RESIN-DENTIN HYBRID LAYER (산표면처리 후 노출된 상아질 교원섬유의 용해가 하이브리드층 형성에 미치는 영향)

  • Jeon, Seong-Min;Son, Ho-Hyun;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.227-241
    • /
    • 1996
  • The effect of collagen dissolution in acid conditioned dentin was morphologically examined by both scanning and transmission electron microscopy. 18 freshly extracted human molars and dentin bonding systems of All Bond 2, Scotchbond Multipurpose, Superbond D-Liner were used in this study. For SEM preparation, each 3 of ~ exposed dentin surfaces were acid conditioned by using various acids within the above three bonding systems respectively. After acid conditioning of the other 3 exposed dentin surfaces as above, they were treated with 1.7% NaOCl for 2 minutes. The remaining 3 dentin surfaces were acid conditioned and treated with 3.3 % NaOCl for 2 minutes. All of the specimens were then fixed in 4 % glutaraldehyde for 12 h at $4^{\circ}C$ and dehydrated in ethanols grades from 50 % to 100 %, then surface changes of the specimens were observed by using SEM. For TEM preparation, exposed dentin surfaces were acid conditioned with the same acid as SEM specimens and treated with 1.7%, 3.3 % NaOCl respectively, then applied with corresponding bonding agents. After the procedures were finished, composite resin were applied on the dentin surfaces and light cured. Small, rectangular sticks with end dimensions of approximately 1 by 1 mm were sectioned and further sample preparative techniques for transmission electron microscopy were performed in accordance with the procedures used for ultrastructural TEM observations of calcified tissues. The results were as follows : 1. In the 1.7 % NaOCl retreated specimens after acid conditioning, the porous dentin surface of intertubular dentin and wide opening of dentinal tubules were appeared. And there were fine irregularities on the intertubular dentin, indicating a clear difference as compared with the acid conditioned specimens. 2. In the 3.3% NaOCl retreated specimens after acid conditioning, the intertubular dentin was further eroded causing a more porous and wider opening of dentinal tubules. Moreover, sharp irregularities on the intertubular dentin were more evident than those of acid conditioned and 1.7% NaOCl retreated specimens. 3. In all of the acid conditioned specimens, the resin-dentin hybrid layer of approximately 3.5mm thickness was formed and the collapsed collagen layer was observed on the uppermost part of hybrid layer in the specimens applied with All Bond 2. The collgen fibrils of intertubular dentin in specimens applied with Scotchbond Multipurpose were running perpendicular to the interface, and electron dense black layer demarcated from the deep unaltered dentin was more evident in the specimen applied with Superbond D-Liner than any other specimens. 4. In the 1.7 % NaOCl retreated specimens after acid conditioning, the resin-dentin hybrid layer of approximately 2.5-3.0mm thickness was formed and the collapsed collagen layer and longitudinally running collagen fibrils as shown in the acid conditioned specimens were observed in the specimens applied with All Bond 2 and Superbond D-Liner. 5. In all of the 3.3% NaOCl retreated specimens after acid conditioning, the evidence of resin-dentin hybrid layer was not identified ; nevertheless, the longitudinally running collagen fibrils remained slightly in the specimens applied with All Bond 2.

  • PDF

Size Effect of Axial Compressive Strength of CFRP Confined Concrete Cylinders

  • Akogbe, Romuald-Kokou;Liang, Meng;Wu, Zhi-Min
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • The main objective of this investigation is to study size effect on compressive strength of CFRP confined concrete cylinders subjected to axial compressive loading. In total 24 concrete cylinders with different sizes were tested, small specimens with a diameter of 100 mm and a height of 200 mm, medium specimens with a diameter of 200 mm and a height of 400 mm, and big specimens with a diameter of 300 mm and a height of 600 mm. The lateral confining pressure of each specimen is the same and from that hypothesis the small specimens were confined with one layer of CFRP, medium and big specimens were performed by two and three layers of CFRP respectively. Test results indicate a significant enhancement in compressive strength for all confined specimens, and moreover, the compressive strengths of small and medium specimens are almost the same while a bit lower for big specimens. These results permit to conclude that there is no size effect on compressive strength of confined specimens regardless of cylinder dimension.

A study on the warpage in injection molded part for various rib design (사출성형품의 리브 설계에 따른 휨의 연구)

  • Lee, Min;Lyu, Min-Young
    • Design & Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.54-61
    • /
    • 2008
  • Warpage, which is one of the molding trouble, acts as possible factor which results in defect in assembly. In this study, a mold was designed to produce specimens with rib parallel to flow direction, specimens with rib perpendicular to flow direction and specimens without rib. This work researched change of warpage according to injection molding condition such as injection pressure, packing pressure, packing time, resin temperature, mold temperature in non-crystalline resins(PC, ABS), crystalline resins(PP, PA66), and 30% glass fiber reinforced-resins(PC, ABS, PP, PA66).Specimens with rib and Crystalline resins show more warpage than specimens without rib and non-crystalline resins, respectively. Glass fiber reinforced-resins and specimens with rib parallel to flow direction show smaller warpage than conventional resins and specimens with rib perpendicular to flow, respectively. Specimens with rib and specimens without rib show reduced warpage as packing time increases. In addition, warpage increase as resin temperature increases. It is found that CAE shows similar tendency with experiment as packing time, resin temperature. when the rib is caused, warpage will reduce and prevent the transformation. product of a irregular form occurs warpage. In the study It'll be basic data that product occurs warpage, preferablity.

  • PDF