• Title/Summary/Keyword: Specimen type

검색결과 1,385건 처리시간 0.026초

후판용접부의 잔류응력과 횡균열의 상관관계 (The relationship between residual stresses and transverse weld cracks in the plate)

  • 이해우;강성원;박종진
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.263-265
    • /
    • 2003
  • The transverse crack, a type of cold crack, occurs perpendicular to the axis of the weld interface, longitudinal residual stresses ($\sigma$k direction) are more important in transverse crack occurrence from my own experience. Specimens were fabricated and welded under actual construction conditions, and then residual stresses of longitudinal stresses were measured for different welding conditions with SAW and FCAW process. The residual stress values for the specimen welded Interpass temperature below 30$^{\circ}C$ was higher than the specimen welded interpass temperature of 100~120$^{\circ}C$. And also the residual stress values for a specimen measured at weld surface, as welded condition, was higher than that of longitudinal residual stresses that was measured from a small test piece, due to the residual stress was relieved in the process of the cutting and machining. Transverse weld cracks were detected in the area of the maximum residual stresses both SAW and FCAW process.

  • PDF

보정계수 산출에 의한 신광원용 표준램프 광속의 검증 (The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor)

  • 황명근;신상욱;이진우
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

WL-RDCB 시편의 동적 균열전파속도와 동적 응력확대계수 (Dynamic Stress Intensity Factors and Dynamic Crack Propagation Velocities in Polycarbonate WL-RDCB Specimen)

  • 정석주;한민구
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.3-9
    • /
    • 1996
  • Dynamic fracture characteristics of Polycarbonate WL-RDCB specimen were investigated. The dynamic crack propagation velocities in these specimens were measured by using both high speed camera system and silver paint grid method developed and justified in the INHA Fracture Mechanics Laboratory. The measured crack propagation velocities were fed into the INSAMCR code(a dynamic finite element code which has been developed in the INBA Fracture Mechanics Laboratory) to extract the dynamic stress intensity factors. It has been confirmed that both dynamic crack arrest toughness and the static crack arrest toughness depend on both the geometry and the dynamic crack propagation velocity of specimens. The maximum dynamic crack propagation velocity of Polycarbonate WL-RDCB specimen was found to be dependent on the material property, geometry and the type of loading. The dynamic cracks in these Polycarbonate WL-RDCB specimens seemed to propagate in a successive manner, involving distinguished 'propagation-arrest-propagation-arrest' steps on the microsecond time scale. It was also found that the relat-ionship between dynamic stress intensity factor and dynamic crack propagation velocities might be represented by the typical '$\Gamma$'shape.

  • PDF

Influence of specimen height on the shear behavior of glass beads in the direct shear test

  • Young-Ho Hong;Yong-Hoon Byun;Jong-Sub Lee
    • Geomechanics and Engineering
    • /
    • 제34권4호
    • /
    • pp.461-472
    • /
    • 2023
  • A box scale affects the shear behavior of soils in the direct shear test. The purpose of this study is to investigate the scale effect on the shear behavior of dilative granular materials by testing specimens of different heights placed in a type C shear box. Experimental tests were performed on specimens composed of glass beads with different heights and equal initial void ratios. Results showed that the peak friction and dilation angles linearly increased with the specimen height; however, the residual friction angle remained relatively constant. Similarly, the shear stiffness increased with the specimen height, rapidly reaching its peak state. Height does not have a significant effect on the total volume changes; nevertheless, a high aspect ratio can be assumed to result in global and homogeneous failure. The results and interpretations may be used as reference for recommending shear box scale in direct shear tests.

Numerical simulation of wedge splitting test method for evaluating fracture behaviour of self compacting concrete

  • Raja Rajeshwari B.;Sivakumar, M.V.N.;Sai Asrith P.
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.265-273
    • /
    • 2024
  • Predicting fracture properties requires an understanding of structural failure behaviour in relation to specimen type, dimension, and notch length. Facture properties are evaluated using various testing methods, wedge splitting test being one of them. The wedge splitting test was numerically modelled three dimensionally using the finite element method on self compacting concrete specimens with varied specimen and notch depths in the current work. The load - Crack mouth opening displacement curves and the angle of rotation with respect to notch opening till failure are used to assess the fracture properties. Furthermore, based on the simulation results, failure curve was built to forecast the fracture behaviour of self-compacting concrete. The fracture failure curve revealed that the failure was quasi-brittle in character, conforming to non-linear elastic properties for all specimen depth and notch depth combinations.

단일 과대하중에의한 크랙지연 거동에 관한 연구

  • 송삼홍;권윤기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 춘계학술대회 논문집
    • /
    • pp.328-332
    • /
    • 1993
  • Single overload tests are carried out for SS41. Specimens are used hollow type and solid type that stress condition prevail plane stress and plane strain at surface crack. According to the crack initiation and propagation period, single overload applies to three regime and overload ratios change into 1.5, 2.0. Crack retardation zones at initation range aren't different in both specimens respectively, however at propagation range come into large scale in hollow specimen. Delayed load cycles come into large scale in solid type. And the more the overload ratio increase, the larger the retardation zone increase but the magnitude doesn't exactly equal to the expected from the overload ratio.

The Rapid Drug Susceptibility Testing of Mycobacterium tuberculosis by GenoType$^{(R)}$ MTBDRplus in Contaminated Specimen

  • Heo, Reun;Kim, Yoon-Sik
    • 대한의생명과학회지
    • /
    • 제19권4호
    • /
    • pp.330-337
    • /
    • 2013
  • There are several methods currently being used to diagnose tuberculosis in patients, such as smear, PCR, tuberculosis culture and X-ray. For a proper medical treatment, antimicrobial susceptibility test and rapid drug susceptibility testing have been operated. Tuberculosis bacilli usually need 3~8 weeks of culture period because of delay in RNA synthesis and require 15~22 hours for generation. After a germ raises in culture, we initiated antimicrobial susceptibility test for a proper treatment. It has some difficulties to give a proper prescription for a tuberculosis patient because antimicrobial susceptibility test requires 4 weeks. To supplement this, we are practicing drug susceptibility testing which allow us to know the sensibility of RMP and INH after 2 or 3 days. But this is only possible when more than 2 positive germ. Therefore, we should practice rapid drug susceptibility testing with culture test. But if media is contaminated by other germs except Mycobacterium tuberculosis, it's hard to interpret result about culture test and to practice antimicrobial susceptibility test and rapid drug susceptibility testing. Because we have to practice again smear, culture test after extracting specimen from the patient, time is consumed and proper patient treatment is postponed. To address these problems and quick patient treatment, rapid drug susceptibility testing is practiced by using GenoType$^{(R)}$ MTDRplus method. As a result of this method we detected sensibility 10 and 7 cases and resistance 0 and 3 cases using RIM and INH respectively with other 1 case toward medicals out of the total 11 test. In conclusion rapid drug susceptibility testing can be used from the contaminated specimen after elimination of contaminated source from culture and proved that it can be practiced for rapid examination of a tuberculosis patient.

복합레진의 중합수축력에 관한 연구 (A STUDY ON THE POLYMERIZATION STRESS OF COMPOSITE RESINS)

  • 김부랑;최호영;민병순;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.331-341
    • /
    • 1992
  • The purpose of this study was to measure the polymerization contraction stress of two types of composite resins; chemical cured type(Cliarfil F II, Kuraray, Japan) and photo-cured type(Photo-Clearfil Bright, Kuraray, Japan). The stresses of composite resin by contraction measured with specially designed measuring device(Fig. 1). The stresses caused by shrinkage during hardening of specimens were measured according to the type of composite resins, thickness of specimen(0.65, 1.30 and 1.95mm), and ratio of catalyst to base in case of only chemical cured composite resin(0.5, 1.0 and 1.5). As the composite resin specimen shrank on hardening, the load cell recorded force vs time automatically on pen-recorder(Toa, Japan) with a cross-head speed 60mm/hr at 0~10 voltages up to 2 hours. The experiments were conducted in a room maintained at $23{\pm}2^{\circ}C$ and relative humidity $50{\pm}10%$. The results were as follows. 1. The contraction stress during hardening was higher in photo cured composite resin than in chemical cured composite resin. 2. The contraction stress during hardening was increased with thickness of composite resin specimen. 3. In chemical cured composite resin, the polymerization contraction stress was decreased with ratio of catalyst and base. 4. The contraction stress during polymerization was higher in early time after insertion of photo cured composite resin and chemical cured composite resin.

  • PDF

평면 변형 조건에서 일축 인장력을 받는 금속 재료의 불연속 변위 각에 대한 연구 (A Study on the Angle of Localization of a Metal Specimen under Uniaxial Tension with Plane Strain Condition)

  • 박재균;김미림
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.275-281
    • /
    • 2011
  • 일반적으로 인장 시험에 주로 사용되는 납작한 형태의 금속 재료에 천천히 인장력을 가하고 그 힘을 증가시키면 어느 순간에 루더스 밴드(Luders band)라고 불리는 소성 변형의 띠가 갑자기 발생한다. 이 띠들은 일정 각도를 가지고 평행하게 발생하며, 여러 연구자들에 의해 특정 경계조건에 대하여 이 띠가 발생하는 조건과 그 각도에 대한 많은 연구가 선행되어 왔다. 본 연구에서는 평면 응력 조건에서 이루어진 Thomas(1961)의 연구를 기반으로 하고 $J_2$ 소성 변형 조건, 힘의 평형방정식, 그리고 구성방정식을 이용하여 평면 변형 조건에서 발생하는 밴드의 각도를 해석적으로 유도하였다. 이 결과는 음향텐서를 이용한 기존의 연구 결과와 일치함을 확인하였다.

탄소강 담금질 공정의 온도 측정방법에 대한 고찰 (A Study on Temperature Measurement for Quenching of Carbon Steel)

  • 김동규;정경환;강성훈;임용택
    • 소성∙가공
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2010
  • To achieve desired microstructure and mechanical property of a manufacturing product, heat treatment process is applied as a secondary process after forging. Especially, quenching process is used for improving strength, hardness, and wear resistance since phase transformation occurs owing to rapid heat transfer from the surface of the specimen. In the present paper, a study on surface temperature measurement for water quenching of eutectoid steel was investigated. In order to determine the temperature history in experiments, three different measuring schemes were used by varying installation techniques of K-type thermocouples. Depending on the measured temperature distribution at the surface of the specimen, convective heat transfer coefficients were numerically determined as a function of temperature by the inverse finite element analysis considering the latent heat generation due to phase transformation. Based on the inversely determined convective heat transfer coefficient, temperature, phase, and hardness distributions in the specimen after water quenching were numerically predicted. By comparing the experimental and computational hardness distribution at three different locations in the specimen, the best temperature measuring scheme was determined. This work clearly demonstrates the effect of temperature measurement on the final mechanical property in terms of hardness distribution.