• Title/Summary/Keyword: Specimen type

Search Result 1,385, Processing Time 0.022 seconds

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

A STUDY ON THE ABRASION RESISTANCE AND SURFACE ROUGHNESS OF THE DENTAL STONES (수종 치과용 석고의 마모저항도 및 표면조도에 관한 비교 연구)

  • Shim, Hye-Won;Yi, Yang-Jin;Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.184-192
    • /
    • 2002
  • The purpose of this study was to investigate the abrasion resistance and surface roughness of conventional dental stones and improved dental stones and newly developed dental stones. Materials included in this study were several dental stones and newly developed dental stone; 2 type III. 6 type IV (including newly developed dental stone). 1 type V Ten specimens for each material, total ninety specimens were made. Each specimen was subjected to 50 complete cycle abrasion under constant load 0.42N at speed or 6mm per sec. The depth after abrasion test was measured for each specimen. Surface roughness before and after abrasion test was compared. The results were as follows ; 1. The resin containing die materials such as Tuff Rock and Resin Rock had superior abrasion resistance. 2. Type IV, V dental stone exhibited greater abrasion resistance than Type III dental stone. 3. The results or the surface roughness showed similar pattern with the abrasion resistance.

The Effect of Specimen Thickness on the Fatigue Crack Propagation Rate (피로크랙전파율에 대한 시험편 두께의 영향)

  • Koh, Sung-Wi;Um, Yoon-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 1988
  • The paper presents the preliminary results of an esperimental study on crack growth under tension-tension fatigue loading. A purpose of the study is to find the effect of the specimen thickness on crack propagation behaviors. The thickness of the low catbon steel specimens the are used in the experiments are 5, 10, 15,20, and 25 mm. the type of specimen considering in the present study is compact tension specimen.Crack growth behaviors are obseved and measured by travelling microscope. From the study, the followings are found; 1. There is a certain specimen thickness that is the shortest farigue life. The fatigue life of 15mm specimen is the shorter then that of any other opecimen 2. The crack initiation of the thick specimen is slower than that of thin specimen. But the crack propagation rate is just the opposite. 3. The range which is the exponent, m of power law(paris) is 1.98-4.59. the thicker the spec-imen is, the higher the value of m is.

  • PDF

A STUDY ON THE CURING EFFECT OF COMPOSITE RESIN BY VISIBLE LIGHT THROUGH TOOTH SUBSTANCE (가시광선(可視光線)의 치질투과(齒質透過) 후(後) 복합(複合)레진 경도(硬度)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Bang, Sang-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.85-93
    • /
    • 1986
  • The purpose of this study was to investigate the curing effect of visible light through tooth substance, 0.5mm, 1.0mm thickness of enamel and dentin were prepared. Experimental specimen were made by Bisfil M & Silux packing into cylindrical brass mold 6.0mm in diameter, 2.0mm and 3.0mm, in height. All specimen were irradiated by visible light (Grip type) model No. SDL-50 Shofu Co.) for 30 seconds through tooth substance. Experimental groups were classified into enamel group (group 1) and dentin group (group 2) according to the thickness of tooth materials and then were divided into 2 subgroups (0.5mm group and 1.0mm group). In experimental groups, visible light irradiated to the specimen through either 0.5mm in thick or 1.0mm in think of tooth material. In Control group specimen were prepared by direct irradiation on the specimen surface of visible light without through tooth substance. The hardness was measured with a Barcol hardness tester (Barber-Colman Co. U.S.A.) for each prepared specimen. The results were as follows: 1. In control group, there were higher hardness values than those of in experimental group. 2. In experimental groups, 0.5mm groups had higher hardness values than 1.0mm groups did. 3. The hardness value at top surface of the specimen were higher than the hardness of bottom surface in each group. 4. Bisfil M had higher hardness values than Silux. 5. In all specimen of 3.0mm height polymerization effect was not occurred at bottom surface except Bisfil M in control group.

  • PDF

Degradation Diagnosis by Void Defects Using a Neural Network (신경망을 이용한 보이드 결함에 의한 열화진단)

  • 최재관;김성홍;김재환
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.940-945
    • /
    • 1998
  • In this paper, we obtained the data, which is required in training the neural network and diagnosing the degradation degree, by introducing the AE detection that is effective method in ordinary degradation diagnosis on activation. Aa the results of generalization tests by appling neural network to the unknown AE patterns obtained from two kinds of specimen, firstly as to evaluate an objective performance of neural network, the recognition ration for no-void specimen and 1[mm] -void specimen are appeared to be 98.9% and 92.5%, respectively. Also, in the evaluation of the adaptability of neural network with a new type of 0.2[mm] -void specimen, it is confirmed that the result appears to be 64% of recognition ratio at 94% of confidence interval coefficient in expectation output 0.2. On the other hand, the recognition capability of the neural network was confirmed by data from no-void and 1[mm] void specimen. The results prove the promising possibility of the application of ANN to discriminate specific void affecting as main degradation source at partial discharge condition in insulator containing multi-void by accummulated data base.

  • PDF

The Thermoelectric Properties of Fe-Si Alloys Prepared by RF Induction Furnace (고주파 진공유도로로 제작한 Fe-Si계 합금의 열전변환특성)

  • 박형진;배철훈
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.7
    • /
    • pp.632-637
    • /
    • 2000
  • Thermoelectric conversion properties of commercial Fe-Si2 and Fe-Si alloy ingots prepared by RF inductive furnace were investigated. As sintering temperature increased, density of the specimen increased and the phase transformation from metallic phases ($\varepsilon$-FeSi, ${\alpha}$-Fe2Si5) to semiconducting phase (${\beta}$-FeSi2) occurred more effectively. The FeSi phase was detected even after 100hrs of annealing treatment. For the Fesi1.95∼FeSi2.05 specimens prepared by RF inductive furnace, the thermoelectric property improved as the composition of the specimen approached to stoichiometric composition FeSi2. Electrical conductivity of the specimen increased with increasing temperatures showing typical semiconducting behavior. From the electrical conductivity measurements, activation energy in the intrinsic region (above about 700 K) was calculated to be approximately 0.46 eV. In spite of non-doping, the Seebeck coefficient for every specimen exhibited p-type conduction due to Si deficiency. Its maximum value was located at about 475 K, and then decreased abruptly with increasing temperatures. The power factor was governed by the Seebeck coefficient of the specimen more significantly than by electrical conductivity.

  • PDF

Thermoelectric Properties of AlN-doped SiC Ceramics (AlN 첨가 SiC 세라믹스의 열전변환특성)

  • Pai, Chul-Hoon
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.11
    • /
    • pp.839-845
    • /
    • 2012
  • The effect of an AlN additive on the thermoelectric properties of SiC ceramics was studied. Porous SiC ceramics with 48-54% relative density were fabricated by sintering the pressed ${\alpha}-SiC$ powder compacts with AlN at $2100-2200^{\circ}C$ for 3 h in an Ar atmosphere. In the undoped specimens, the Seebeck coefficients were positive (p-type semiconducting) possibly due to a dominant effect of the acceptor impurities (Al, Fe) contained in the starting powder. With AlN addition, the reverse phase transformation of 6H-SiC to 4H-SiC was observed during the sintering process. The electrical conductivity of the AlN doped specimen was larger than that of the undoped specimen under the same conditions, which might be due to a reverse phase trans-formation. The Seebeck coefficient of the AlN doped specimen was also larger than that of the undoped specimen. The density of specimen and the amount of addition had significant effects on the thermoelectric properties.

Method of Ga removal from a specimen on a microelectromechanical system-based chip for in-situ transmission electron microscopy

  • Yena Kwon;Byeong-Seon An;Yeon-Ju Shin;Cheol-Woong Yang
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.22.1-22.6
    • /
    • 2020
  • In-situ transmission electron microscopy (TEM) holders that employ a chip-type specimen stage have been widely utilized in recent years. The specimen on the microelectromechanical system (MEMS)-based chip is commonly prepared by focused ion beam (FIB) milling and ex-situ lift-out (EXLO). However, the FIB-milled thin-foil specimens are inevitably contaminated with Ga+ ions. When these specimens are heated for real time observation, the Ga+ ions influence the reaction or aggregate in the protection layer. An effective method of removing the Ga residue by Ar+ ion milling within FIB system was explored in this study. However, the Ga residue remained in the thin-foil specimen that was extracted by EXLO from the trench after the conduct of Ar+ ion milling. To address this drawback, the thin-foil specimen was attached to an FIB lift-out grid, subjected to Ar+ ion milling, and subsequently transferred to an MEMS-based chip by EXLO. The removal of the Ga residue was confirmed by energy dispersive spectroscopy.

AN ELECTROCHEMICAL STUDY ON SURFACE FINISH OF DENTAL AMALGAM (아말감의 표면연마에 관한 전기화학적 연구)

  • Suk, Chang-In;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.18-32
    • /
    • 1991
  • The purpose of this study was to observe characteristic properties of amalgam through the polarization curves and SEM images from 4 type amalgams (Amalcap, Shofu spherical. Dispersalloy and Tytin) with 3 different surface finish procedures (polishing, burnishing and carving) by using the potentiostats (EG & GPARC) and SEM (Jeol JSM-35). After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of mechanical amalgamator (Samki), the triturated mass was inserted into the cylndrical metal mold which was 12 mm in diameter and 10 mm in height and was pressed with $100kg/cm^2$. 4 specimens of each type amalgam were burnished with egg burnisher and another 4 specimens of each type amalgam were carved with Hollenback carver. Above 8 specimens and remaining untreated 4 specimens were stored at room temperature for about 7 days. Untreated 4 specimens of each type amalgam were polished with abrasive papers (Deer) from #400 to #1200 and finally on the polishing cloth with $0.5{\mu}m$ and $0.06{\mu}m$ $Al_2O_3 $ powder suspended water. Anodic polarization measurements was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution at $37^{\circ}C$. The open circuit potential was determined after 30 minutes immersion of specimen in electrolyte. The scan rate was 1 mV/sec and the surface area of amalgam exposed to the solution was $0.64cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). SEM images of each specimen were taken after + 800 mV (SCE) polarization. The results were as follows: 1. The corrosion potential of high copper amalgam was more anodic than that of low copper amalgam. 2. The polished amalgam were more resistant to corrosion than any other burnished and carved amalgam. 3. In the case of polishing, current density of high copper amalgam was lower than that of low copper amalgam.

  • PDF