• Title/Summary/Keyword: Specimen Preparation

Search Result 238, Processing Time 0.032 seconds

A Study on the Measurement of two Dimensional Strain by ESPI Method and Image processing (E.S.P.I법과 화상처리에 의한 2차원의 스트레인 측정에 관한 연구)

  • KIM, K.S.;KIM, H.S.;YANG, S.P.;KIM, C.W.;JUNG, Y.G.;HONG, M.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • ESPE(Electonic-Speckle-Pattern-Interferometry) is very useful method for measuring In-plane displacement. Using the CW-Laser and Image processing system, it is possible to measure displacement and strain. Unlike traditional straingauge or moire' method, ESPI method requires no special surface preparation or attachments and can be measured In-plane displacement with no contact and real time. In this experimental specimen was loaded in paralled with loadcell, which provided loading step. The specimen was sheet plate, which was attached straingauge in x-y direction. In this study provides an example of how ESPI has been used to measure two dimensional displacement and strain distribution in this specimen. The results measured by ESPI compare with the data which was measured straingauge method in tensile testing at 1 ton range.

  • PDF

X-Ray Fluorescence Analysis by Stearic Acid-Extraction Technique (스테아르산 추출법에 의한 X-선 형광분석)

  • Tae Sub O;Man Ho Lee;Young Kyu Park
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 1984
  • To preconcentrate trace elements, microgram amounts of 5 heavy metals (Cu, Co, Ni, Zn and Cd) were precipitated with 8-hydroxyquinoline (oxine) and metal oxinates were extracted with stearic acid. And then each of the molten stearic acid extract with stearic acid. And then each of the molten stearic acid extract was poured into a glass ring and cooled for specimen preparation. The obtained specimens were analyzed by X-ray fluorescene spectrometry. And then conditions of precipitation formation and extraction, reproducibility, sensitivity and detection limit were observed. The relative standard deviation of specimen preparation was 1.0~5.7% and the detection limit was 5~$50{\mu}g$/100ml. The proposed preconcentration procedure exhibited a considerable inhancement and simplicity in preparing specimens.

  • PDF

Standardization of Ice Mechanics Experimental Procedures in a Cold Room (Cold Room을 이용한 얼음 및 동토의 재료특성 계측 실험기법의 표준화)

  • Kim, Jung-Hyun;Choi, Kyung-Sik;Seo, Young-Kyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.60-66
    • /
    • 2007
  • The first Korean cold room facility for ice mechanics experiments was assembled in 2004. Since then, the $4m{\times}6m$ cold room facility has been used, extensively under various environmental and loading conditions. After reviewing published references on cold room testing methods and also by trial and error, the standard procedures for testing and preparing laboratory ice material were established for the measurement of basic ice properties. In this paper, laboratory experimental techniques with the cold room facility and standard procedures established for ice material properties are introduced. Test specimens include laboratory-grown fresh water ice and frozen soils. Tests are carried out for unconfined compressive strength. Preparation and dimension of the specimen are the most important issues arising in cold room tests. The details of specimen preparation, testing procedure and strength test results are also discussed.

Determination of crystallinity index of cellulose depending on sample preparation and analysis instruments (시료 조건 및 측정방법에 따른 셀룰로오스의 결정화도 평가)

  • Ahn, Jung-Eon;Youn, Hye-Jung;Joung, Yang-Jin;Kim, Tae-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.43-50
    • /
    • 2012
  • The crystallinity index is an important characteristic of cellulose. The crystallinity value is different depending on the adopted instrument. In this study, we determined a crystallinity index of cotton and wood celluloses using wide-angle X-ray scattering (WAXS), powder X-ray diffractometer (PXRD), and cross polarization/magic angle spinning solid-state $^{13}C$ nuclear magnetic resonance spectroscopy (CP/MAS solid-state $^{13}C$ NMR). The specimen was prepared in forms of powder, sheet and pallet. With the comparison of the obtained crystallinity indices of the cellulose, the effects of the analysis instrument, the sample preparation and analysis method were investigated. Among three instruments, the crystallinity indices by PXRD and NMR had a good relationship and reproducibility, and WAXS gave the crystallinity index with poor reproducibility. In the case of analysis methods of crystallinity indices, the Segal method showed higher value than that of the Ruland-Vonk method. We expect that this study would be applicable to evaluate the crystallinity index of various cellulose materials with accuracy and reproducibility.

Development of a Proficiency Test Specimen for Enumerating Escherichia coli in Molluscan Bivalve Shellfish

  • Kwon, Ji-Young;Song, Ki-Cheol;Son, Kwang-Tae;Yu, Hong-Sik;Kim, Poong-Ho;Shin, Soon-Bum;Mok, Jong-Soo;Lee, Ka-Jeong;Oh, Eun-Gyoung;Yoon, Ho-Dong;Lim, Keun-Sick;Kim, Young-Mog
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.3
    • /
    • pp.226-229
    • /
    • 2011
  • This study was conducted to develop a proficiency test (PT) specimen for the enumeration of Escherichia coli, a sanitary indicative bacterium, in molluscan bivalve shellfish. The common mussel Mytilus edulis was chosen as a matrix for the PT specimen. Mussels were artificially bioaccumulated for approximately 3 h with E. coli culture. After determining the homogeneity of samples, samples were distributed to 17 participants involved in the proficiency testing program. The enumeration of E. coli was performed by the most probable number method of the American Public Health Association. Statistical evaluations of the results obtained from inter- and intra-laboratory variation indicated no significant differences in the accuracy of these techniques between participants, indicating z-scores of ${\leq}{\pm}2$ and suggesting that preparation of the PT specimen for enumerating E coli in shellfish was successful.

Effect of Ultrasonic Bath in Preparing Specimens for Transmission Electron Microscopy (전자현미경 시료 제작에 있어 Ultrasonic bath의 유용성에 관한 연구)

  • Lim, Byung-Soo;Choi, Jeung-Mok;Kang, Dae-Young
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.315-328
    • /
    • 1998
  • The present study was carried out to investigate the effect of ultrasonic bath in tissue preparation for transmission electron microscopy. The method used standard reagents and media, and employed ultrasonic bath agitation to accelerate fluid exchange. The liver kidney, stomach and cardiac muscle tissues of male Sprague-Dawley rats were used for the experiment, and the experimental design was divided into 4 groups; The control group using rotators (Traditional method, 1,625 mins) and the three experimental groups using ultrasonic bath (UB) in the primary fixation through the infiltration processes (UB I; 62.5 mins, UB II; 125 mins, UB III; 250 mins). The results were as follows; 1. In the control group, tissues were easily sectioned, and showed well preserved intact membranes, and cell organelles such as mitochondria, lysosome, peroxisome, rough endoplasmic reticulum and smooth endoplasmic reticulum. 2. In the UB treated group I, tissues showed holes due to the inadequate removal of both water and fluids used in the dehydration process. Also the mitochondria of cell organelles, especially, showed swollen intracristal spaces and dense matrices due to poor fixation. 3. In the UB treated group II, tissues showed good preservation of cell organelles and specimen slice sections. Also, no holes were observed. 4. In the UB treated group III, tissues showed leaching of structural components in the cytoplasm, but no holes were observed. In conclusion, the ultrasonic bath procedure takes approximately 120 minutes from specimen fixation to resin infiltration and gives excellent results.

  • PDF

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

TEM analysis of IBAD/RABiTS substrates prepared by Tripod polishing (Tripod polishing을 이용한 IBAD/RABiTS 기판의 TEM 분석)

  • Choi, Soon-Mee;Chung, Jun-Ki;Yoo, Sang-Im;Park, Chan;Oh, Sang-Soo;Kim, Cheol-Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Sample preparation plays a critical role in microstructure analysis using TEM. Although TEM specimen has been usually prepared by jet-polishing or Ar-ion beam milling technique. these methods could not be applied to YBCO CC which is composed of IBAD or RABiTS substrates, several buffet layers, and YBCO superconducting layer because of big difference in mechanical strengths between the metallic phase and oxide phases. To obtain useful cross-sectional information such as interface between the phases or second phases in YBCO CC, it is prerequisite to secure the large area of thin section in the cross-sectional direction. The superconducting layer or the buffer layers are relatively weak and fragile compared to the metallic substrate such as Ni-5wt%W RABiTS of Hastelloy-based IBAD, and preferential removal of weak ceramic phases during polishing steps makes specimen preparation almost impossible. Tripod polisher and small jig were home-made and employed to sample preparation. The polishing angle was maintained <$1^{\circ}$ throughout the polishing steps using 2 micrometers attached to the tripod plate. TEM specimens with large and thin area could be secured and used for RABiTS/IBAD substrate analyses. In some cases, additional Ar-beam ion milling with low beam current and impinging angle was used for less than 30 sec. to remove debris or polishing media attacked to the specimens.