• Title/Summary/Keyword: Specific on-resistance

검색결과 1,146건 처리시간 0.029초

SOFC의 YSZ 전해질에 대한 혼합공기극 연구 (Study on Composite Cathode for YSZ Electrolyte in SOFC)

  • 이창보;배중면
    • 대한기계학회논문집B
    • /
    • 제31권1호
    • /
    • pp.62-67
    • /
    • 2007
  • Optimization of cathode properties for intermediate temperature-operating SOFC (IT-SOFC) is carried out by using composite-type electrode structure in this study. Composite cathode may lower cathode overpotential by enhancing mixed ionic-electronic conductivity. In this study, particularly, LSM/YSZ, LSF/YSZ, LSCF/CGO, and PSC/CGO were selected as cathode materials. LSM/YSZ composite cathode showed the best performance of about 0.9${\Omega}cm^2$ at $700^{\circ}C$. It is inferred that the resistance is mainly affected by the reactivity between cathode and electrolyte which can cause the formation of resistive phases. Area specific resistance (ASR) characteristics were not changed significantly with decreasing sintering temperature of cathode, because reaction sites were increased even with worse adhesion of cathode on electrolytes.

다층막을 이용한 거대자기저항(GMR)의 특성 연구 (A Study on the Characteristics of Giant Magneto Resistance using Multi Layers)

  • 김병우;이영석
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.113-118
    • /
    • 2008
  • We have developed an integrated giant magneto resistance using not only circuit but also integrating technique with semiconductor for automobile application. It has four elements used for giant magneto resistance sensor. Ni-Fe/Cu multi layers were prepared on a glass substrate by magnetron sputtering. The dependence of magneto resistance on the thickness of the Ni-Fe and Cu layers was investigated. The MR ratio showed a saturated a peak at Cu layer $10{\AA}$, Ni-Fe layer $50{\AA}$, where the MR ratio is about 8.7% at room temperature. By means of Ni-Fe multi film and specific integrating technique, these new giant magneto resistance sensor showed excellent resistance characteristics.

침전이 수반되는 케이크 여과 II: 새로운 분석과 케이크에 도입되는 현탁액의 고체 질량분율 (Filtration with Sedimentation II: New Analysis and Solid Mass Fraction of Suspension Entering Cake)

  • 임성삼
    • Korean Chemical Engineering Research
    • /
    • 제50권3호
    • /
    • pp.535-544
    • /
    • 2012
  • 수평 여과매체를 사용한 케이크 여과에서는 침전이 수반된다. 이 침전 현상을 고려하지 않을 경우 여과기간의 케이크 평균비저항 값이 두 배 이상까지도 잘못 측정될 수 있다. 저자의 전번 논문에서는 여과기간에 침전으로 인해 케이크에 들어가는 현탁액의 고체분율이 변화한다는 것을 이론적으로 주장하였으나, 그 변화가 어느 정도인지를 알아내지 못하였다. 이 논문에서는 먼저 여과-투과 실험방법에 대한 분석에서 투과기간에 측정된 케이크 평균비저항 값이 옳다는 것을 여러 방법으로 증명하고, 여과기간에 통상적인 방법으로 측정된 평균비저항 값은 여과가 진행되는 순간의 현탁액의 고체분율 대신 초기 고체분율을 사용하므로 정확하지 못하다는 것을 입증하였다. 여과와 투과에서 측정된 실험값을 사용하여, 여과 진행 동안 침전에 의해 변화한 현탁액의 고체분율을 계산하였다. 그 후 여과 진행 동안 측정한 현탁액의 높이 변화 값과 이 논문에서 새로 만든 수식을 사용하여 여과 진행 중의 현탁액 고체분율을 결정하였다. 두 가지 방법으로 결정된 현탁액의 고체분율을 비교하여 두 가지가 거의 일치함을 입증하였다.

전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구 (A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization)

  • 하상안;임경택;신남철
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

전도성 니켈분말-에폭시수지 복합체의 전기적 특성 (Electrical Properties of Conductive Nickel Powder-Epoxy Resin Composites)

  • 오대희;임덕점;이정은;박영희;오승민
    • 한국응용과학기술학회지
    • /
    • 제31권2호
    • /
    • pp.329-336
    • /
    • 2014
  • The conductive polymer composites have attracted considerable attention in the field of industry due to their electrical properties. To understand electrical properties of the composites, their volume specific resistance was measured. Electrical conductivity results showed percolation phenomena. Percolation theories are frequently applied to describe the insulator-to-conductor transitions in the composites composed of conductive filler and insulating matrix. It was found that the percolation threshold strongly depends on the aspect ratio of filler particles. The critical concentration of percolation formed is defined as the percolation threshold. The purpose of this study was to examine electrical properties of the epoxy resins filled with nickel. The sample was prepared using vehicle such as epoxy resin replenished with nickel powder, and the evaluation on their practical use was performed in order to apply them to electric and electronic industry as well as general field. The volume specific resistance of epoxy resin composites was 4.666~13.074 when using nickel powder. Weight loss of the conductive composites took place at $350^{\circ}C{\sim}470^{\circ}C$.

비중의 변화와 발수제 첨가가 경량기포콘크리트의 물성에 미치는 영향 (Effect of the Variation of Speccfic Gravity and the Addition of Water Repellent Agent on the Physical Properties of Autoclaved Lightweight Concrete)

  • 노재성;황의환;홍성수;이범재
    • 콘크리트학회지
    • /
    • 제9권2호
    • /
    • pp.137-144
    • /
    • 1997
  • 발수제의 유무와 알루미늄분말의 분말도 및 첨가량을 조절하여 비중을 0.4에서 0.7로 변화시켜 비중과 ALC의 기초물성, 내동해성 및 내구성과의 관계를 조사하였다. 압축 및 인장강도는 비중이 0.4에서 0.7로 증가함에 따라 발수제의 첨가량에 관계없이 증가하였고 발수제의 첨가량이 증가하면 내동해성은 개선되었으며 흡수율은 감소하였다. 입경이 작은 AI분말을 이용항 제조한 ALC의 박리에 의한 체적감소율은 낮게 나타났으며 일면동결지속시험 및 기중동결수중융해시험에서도 내동해성이 우수한 것으로 나타났다.

Body Plethysmograph를 이용한 Airway Resistance Curve의 임상적 의의 (Clinical Significance of Airway Resistance Curve by the Body Plethysmograph)

  • 천선희
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권2호
    • /
    • pp.218-225
    • /
    • 1995
  • 연구배경: 기도저항은 body plethysmograph를 이용하여 flow/alveolar pressure의 관계를 측정함으로써 얻어질 수 있는데, 기도저항이 정상인 경우 oscillooscope 상에서 얻어지는 resistance curve가 거의 linear 하나 증가된 경우에는 그 모양이 기울어지거나 loop을 형성하는 경우가 많아 이러한 curve를 분석하여 환자의 임상평가에 도움이 되는 결과를 얻고자 하였다. 방법: 기도저항이 증가되어 있는 환자를 대상으로 body plethysmograph에서 quiet breathing시에 얻어진 resistance curve의 형태를 분석하여 폐기능을 비교하였다. 결과: 1) Resistance curve는 type 1: linear, type 2: ovoid, type 3: sigmoid, type 4: scoop, type 5: paisley의 5가지 형태로 구분할 수 있었으며, 1예를 제외한 type 3과 type 4 및 5는 loop을 형성하였다. 2) Curve의 형태가 특정 질환에 특징적이지는 않았으나 급성질환은 주로 type 1, 및 2, 만성기류폐쇄는 주로 type 3, 4 및 5에 속하였으며, 기관지 천식이나 오래된 폐결핵은 그 정도에 따라 type 1 에서 5까지의 형태를 모두 보였다. 3) Type 1에서 type 5로 갈 수록, loop을 형성 할 수록 기도폐쇄가 심하고 기도저항이 증가되며 잔기량이 커지는 경향을 보였다. 결론: 기도저항을 측정할 경우 기도저항의 측정치 뿐 아니라 resistance curve를 분석하여 기도폐쇄와 air trapping의 정도를 판단하는데 도움을 얻을수 있으며, resistance curve의 모양이 특정 질환에 특징적이지는 않았지만 호기시 loop이 형성되는 경우 심한 기도폐쇄를 시사하였다.

  • PDF

Rhizobacterial Exopolysaccharides Elicit Induced Resistance on Cucumber

  • Park, Kyung-Seok;Kloepper, Joseph W.;Ryu, Choong-Min
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1095-1100
    • /
    • 2008
  • The role of exopolysaccharides (EPSs) from a plant growth-promoting rhizobacterium, Burkholderia gladioli IN26, on elicitation of induced systemic resistance was investigated. A purified EPS induced expression of PR-1a::GUS on tobacco and elicited induced resistance against Colletotrichum orbiculare on cucumber. The maximum level of disease protection was noted when seeds were soaked in 200 ppm of the EPS. Our results indicate that EPS from specific rhizobacteria can elicit induced resistance and suggest that bacterial EPS might be a useful elicitor of resistance under field conditions.

전기이중층 커패시터의 특성에 미치는 혼성 도전재의 영향 (Effect of Composite Conductor on Characteristics of Electric Double Layer Capacitor)

  • 김익준;이선영;문성인
    • 한국전기전자재료학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-111
    • /
    • 2004
  • This work describes the effect of composite conductor on the characteristics of electric double layer capacitor. Test cell, which was fabricated with conducting composite consisted of 80% of SPB and 20% of VGCF, exhibits the better tate capability and the lower resistance than those of the cells fabricated with single electronic conductor. These enhanced properties could be related with the decrease of contact resistance between the activated carbon powders.

평판 유도 결합형 $CH_4/H_2/Ar$ 플라즈마를 이용한 GaN 건식 식각에서 공정변수가 저항성 접촉 형성에 미치는 영향 (The Effects of Etch Process Parameters on the Ohmic Contact Formation in the Plasma Etching of GaN using Planar Inductively Coupled $CH_4/H_2/Ar$ Plasma)

  • 김문영;태흥식;이호준;이용현;이정희;백영식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권8호
    • /
    • pp.438-444
    • /
    • 2000
  • We report the effects of etch process parameters on the ohmic contact formation in the plasma etching of GaN. Planar inductively coupled plasma system with $CH_4/H_2/Ar$gas chemistry has been used as etch reactor. The contact resistance and the specific contact resistance have been investigated using transfer length method as a function of RF bias power and %Ar gas concentration in total flow rate. AES(Auger electron spectroscopy) analysis revealed that the etched GaN has nonstoichiometric Ga rich surface and was contaminated by carbon and oxygen. Especially large amount of carbon was detected at the sample etched for high bias power (or voltage) condition, where severe degradation of contact resistance was occurred. We achieved the low ohmic contact of $2.4{\times}10^{-3} {\Omega}cm^2$ specific contact resistance at the input power 400 W, RF bias power 150 W, and working pressure 10mTorr with 10 sccm $CH_4$, 15 sccm H2, 5 sccm Ar gas composition.

  • PDF