실제조건에서 기준 밀도계와 가스 분석기에 의한 밀도 측정 결과 비교 (Density Measurement Comparisons of Specific Gravity Meter and Gas Chromatography in the Field)

  • 이강진;허재영;하영철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.90-96
    • /
    • 1999
  • In contracts for sales of natural gas between sellers and buyers, it is not suncient to only measure a volumetric quantity of gas in flowing conditions in metering station. Therefore the measured volumetric quantity must be converted to that of reference conditions. The density of the natural gas required in such a calculation can be measured directly or estimated from the equation of sate or any other experimental methods. The specific gravity meter is the apparatus used to measure the density of fluids under the reference conditions and it can be widely used in industrial areas, especially in massive flow rate natural gas industry. This study has been carried out in an attempt to improve measurement accuracy of natural gas flow rate calculation, providing the adequate installation and proper operation conditions of specific gravity meter. The test results are 1) the density measurement errors in case of using methane and standard gas as calibration gases are smaller than using methane and nitrogen gas, 2) the periodical calibration to maintain accurate density measurements is essential, and 3) the specific gravity meter is sensitive to changes of environmental conditions, especially environmental temperature surrounding the specific gravity meter.

  • PDF

기준 밀도계의 측정 오차 분석에 관한 연구 (A Study on the Analysis of Measurement Errors of Specific Gravity Meter)

  • 이강진;허재영;하영철;안승희;이승준;이철구
    • Korean Chemical Engineering Research
    • /
    • 제40권6호
    • /
    • pp.676-680
    • /
    • 2002
  • 기준 밀도계는 기준 조건하에서 밀도를 측정하는 기기로서, 산업계에서 특히 대유량 천연가스 계량에 폭 넓게 사용된다. 본 연구에서는 기준 밀도계의 적정 설치 및 운영방안을 제시하여 천연가스 유량 측정 정확도를 향상시키고자 현장 실험을 수행하였다. 실험 결과, 교정가스로 메탄과 질소가스 대신 메탄과 표준가스로 교정한 실험결과가 작은 밀도오차를 발생하고, 정확한 밀도 측정을 위해서는 정기적인 교정이 필수적이며, 또한 기준 밀도계는 주위 조건에 민감하게 반응하여, 주위 온도가 높으면 오차가 증가하는 것도 확인되었다.

마이크로캡슐 잠열 축열재 혼합수의 열물성에 관한 연구 (A Study on Thermo-Physical Properties of Microencapsulated Phase Change Material Slurry)

  • 임재근;최순열;김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.962-971
    • /
    • 2004
  • This paper has dealt with thermo-physical properties of microencapsulated phase change material slurry as a latent heat storage material having a low melting point. The measured results of the thermo-physical properties of the test microencapsulated phase change material slurry, those are, density, specific heat, thermal conductivity and viscosity, were discussed for the temperature region of solid and liquid phases of the dispersion material (paraffin). The measurements of these properties of microencapsulated phase change material slurry have been carried out by using a specific-gravity meter, a water calorimeter, a differential scanning calorimeter(DSC), a transient hot wire method and rotating type viscometer, respectively. It was clarified that the additional properties law could be applied to the estimation of the density and specific heat of microencapsulated phase change material slurry and also the Euckens equation could be applied to the estimation of the thermal conductivity of this slurry.

광센서 점적계를 이용한 정맥내 주입률 조절기의 개발 (Development of an IV Infusion Rate Regulator Using Optical Drip Rate Meter)

  • 양윤석;김희찬
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.127-128
    • /
    • 1998
  • It is necessary to maintain constant intravenous (IV) infusion rate. While infusion pump is able to control infusion rate with great accuracy, its rather large size and weight make it difficult for patients to move around. The most commonly used infusion device is gravity IV infusion set with its administration chamber being clamped according to the observed drip rate. In this case it may be easier and more accurate to maintain IV rate to given value if we automate the drip-counting process and tube-clamping work by electronic devices. We calculated volume infusion rate of specific fluid using optical drip rate meter which we had developed. To regulate fluid flow rate, we equipped the rate meter which we had developed with a miniaturized clamping apparatus using DC motor. Also, we Implemented drip detection and clamp control algorithm with PIC16C73 $\mu$-controller (Microchip). This system provides user interface through LCD display and key buttons.

  • PDF

Hemoglobin 평가를 위한 초기 기구의 특성 및 측정법 고찰 (A Review of the Characteristics of Early Apparatus and Methods for Hemoglobin Estimation)

  • 권영일
    • 대한임상검사과학회지
    • /
    • 제48권4호
    • /
    • pp.401-410
    • /
    • 2016
  • 19세기 후반부터 과학적 논리와 기술이 임상병리학 분야에 적극적으로 활용되기 시작하였다. 이로 인해 많은 검사들이 도구와 기기를 이용하기 시작하였다. 이 때 등장한 혈색소 측정법 중에서 육안색조비교법이 일반적으로 사용되었고, 비중측정법과 가스정량법은 활용도가 낮았다. 육안색조비교법을 적용한 기기로는 Gowers' hemoglobinometer, von Fleischl's hemoglobinometer, Dare's hemoglobinometer, Oliver's hemoglobinometer 그리고 Haden-Hausser hemoglobinometer, Spencer Hb meter 등이 있다. 육안색조비색법은 초기에 혈액을 증류수를 이용하여 희석하고 용혈시킨 후 색조를 측정하는 방법을 활용하였지만, 이후 측정방법을 개선하면서 혈액을 희석없이 측정하거나 발색의 안전성을 위해 acid 혹은 alkaline hematin을 형성시키는 방법들로 발전하였다. 비중을 이용한 측정법으로 Hammerschlag method와 Schmaltz and Peiper's method가 활용되었지만 대중적으로 사용되지는 않았다. 가스정량법은 van Slyke 장치를 이용하여 간접적으로 헤모글로빈 농도를 추정하는 방법으로 가장 정확한 결과를 제공하였다. 본 조사에서는 19세기 후반과 20세기 초 중반까지 사용된 혈색소 측정기기와 측정법에 대한 특징 및 제한점 등을 알아 보았고, 이를 통하여 현재의 측정방법 및 새롭게 등장하는 기술들에 대한 이해와 응용력을 향상시키고자 하였다. 또한 이번 조사가 진단검사 기술분야의 다양한 역사유물에 대한 고찰뿐만 아니라 역사자료 체계화에 대한 필요성을 자각하는 시발점이 되기를 희망한다.

Deep Of Discharge Meter

  • Rattanaphaiboon, Somphon;Sawaengsinkasikit, Winya;Tipsuwanporn, Vittaya;Roengruen, Prapas
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.809-812
    • /
    • 2005
  • Battery is an energetic collector of solar cell system. Battery which is used in the system must have many qualities in the followings. The battery must be "Deep Cycle Battery" type. In addition, the battery is Cleary indicated the percentage of DOD. The indication of DOD is used for calculation other valve used in solar cell system. Currently, the percentage of DOD of battery is fixed by battery manufacture. If users would like to calculate is introduced % DOD, the users have to check the battery at least 12 months. This article is introduced battery deep of discharge meter by using theory of lead acid battery under deep cycle type and including the theory of DC. Current and internal resistance of battery. The data used for analyzing are collected according to the theories. The data will be calculated by monitor unit and controller systems.

  • PDF

비중계와 SGERG 방정식을 이용한 천연가스 열량 산정에 관한 연구 (A Study on the Evaluation of Heating Value of Natural Gas Using SGERG Equation and a Specific Gravity Meter)

  • 하영철;이강진
    • 에너지공학
    • /
    • 제9권4호
    • /
    • pp.303-308
    • /
    • 2000
  • 천연가스 도입 다변화 정책이 시행된 이후 공급 천연가스의 조성이 산지별로 적지 않게 차이나고 있으며 이에 따라 부피와 열량으로 이원화된 기존 천연가스 상거래 단위 체계를 열량 단위로 일원화하는 방안이 검토되고 있다. 열량을 상거래 단위로 하기 위해서는 고가의 가스분석기사 필요하지만 공급량이 극히 적은 상당수 공급설비에까지 이를 적용하기는 어려우며 이로 인해 보다 경제적인 방안이 모색되고 있다. 이러한 방안의 하나로 본 연구에서는 SGERG식과 비중계를 이용한 열량산정 방법을 분석해 보았다. 이를 위해 압축계수식인 SGERG식을 열량식으로 변형하고 불확도 분석을 하였다. 또한 열량계산에 필요한 비중, 이산화탄소 함량, 질소 함량의 측정 또는 예측의 타당성도 검토했고 실제 현장 데이터를 통해 본 방법의 적정성도 확인하였다. 그 결과 본 연구에서 제시한 방법을 이용하면 가스분석기와 유사한 불확도로 열량 산정을 할 수 있음을 확인하였다.

  • PDF

영구 자석 바퀴를 이용한 벽면 이동 로봇의 설계시의 설계지침 (Guideline for the Design of Wall-Climbing Mobile Robot Using Permanent Magnetic Wheels)

  • 이화조;김은찬;한승철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.548-553
    • /
    • 2002
  • Most tasks of the large vertical or ceiling structures have been carried out by human power. Those tasks require us much operation costs and times, safety devices, etc. So the need of automation for those tasks have been rising. That automation needs a wall-climbing mobile vehicle. Most former researches are things about attachment devices and moving mechanisms. A wall-climbing mobile vehicle must be designed by a method different from the case of the vehicle of the horizontal environment. That is because gravity acts as a negative role on the stability of a wall-climbing vehicle. In this thesis, the particular shape characteristics of a wall-climbing mobile vehicle are derived by the wall-environment modeling. In addition, some design constraints of the permanent magnetic wheel as an attachment device was studied. According to those requirements and constraints, one specific wall-climbing mobile vehicle was designed and some experiments were made on the attachment ability of that vehicle.

  • PDF

지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발 (A development of new dielectric tracer test method for groundwater logging: laboratory soil column test)

  • 김만일;김형수;정교철
    • 지질공학
    • /
    • 제14권3호
    • /
    • pp.301-311
    • /
    • 2004
  • 다공질매질을 구성하고 있는 다양한 매질들의 전기적 특성 중의 하나인 유전율상수를 이용하여 지하수 유동 및 매질의 구조를 파악하기 위한 새로운 유전율추적자시험법(dielectric tracer test method)을 본 연구에서 제안하였다. 추적자물질로는 비중이 물과 동일한 에탄올혼합액체(ethanol mixing liquid, EML)를 제작하였으며, 각기 다른 공극률을 갖는 포화 표준사 및 강모래 층에 대해 매질의 유전율상수를 측정할 수 있는 FDR system및 측정센서를 적용해 추적자시험을 실시하였다. 또한 이들의 결과와 비교하기 위하여 추적자물질인 염분농도 $3\%$를 갖는 염분수용액의 농도 변화를 electro multi-meter로 측정하여 비교 검토하였다. 두 시험결과에서 EML추적자시험의 경우, 각각의 포화 흙칼럼에서의 EML 농도변화를 명확히 확인할 수 있었으나, 염분수용액을 적용한 시험에서는 이들이 지속적으로 칼럼 내 하단부로 침전되어 염분농도 변화에 의한 물의 침투 이동은 확인할 수 없었다. 이는 염분수용액의 비중이 물보다 무겁기 때문에 포화토 내 물의 이동 속도에 비례하여 지속적으로 하단부로 침전이 이루어지는 것을 알 수 있었다. 따라서 본 연구에서는 물의 비중과 동일한 EML 추적자물질과 이들의 유전율상수 변화를 측정할 수 있는 FDR system을 적용하여 유전율추적자시험의 적용 가능성을 실내추적자시험을 통하여 확인하였다.

자유낙하 콘관입시험법을 활용한 휴대용 다짐도 측정기의 실내시험을 통한 검증 연구 (A Study on the Verification of an Indoor Test of a Portable Penetration Meter Using the Cone Penetration Test Method)

  • 박근현;양안승
    • 한국지반환경공학회 논문집
    • /
    • 제20권2호
    • /
    • pp.41-48
    • /
    • 2019
  • 국내에 많은 도로공사, 공항공사, 항만공사, 구조물 되메우기 공사 등의 토목공사에서 흙의 다짐은 가장 중요한 공정 중 하나이다. 특히 도로공사에서 흙의 다짐공사는 노체다짐과 노상다짐으로 구분하며 다짐도 부족으로 부실공사의 원인으로 작용하기도 하는 중요한 작업이다. 현재는 여러 가지 다짐도 측정방법이 있으나 가장 많이 사용되는 평판재하시험이나 모래치환법에 의한 흙의 단위중량 시험방법을 가장 많이 사용하고 있으나 경제성이 없어 여러 측정방법이 개발되고 있다. 간편한 다짐도 측정 방법의 목적으로 측정기를 개발하고 제작한 것이 자유낙하 관입깊이별 다짐도 시험기(Free-Fall Penetration Test; FFPT)이다. 본 연구에서는 실내시험을 위하여 균질한 시료를 공사현장에서 확보하여 체가름 시험을 통해 흙을 분류하고 입도분석시험과 비중시험을 실시하였다. 자유낙하 관입깊이별 다짐도 시험기(FFPT)의 원리는 지구중력을 이용한 자유낙하 물체의 선단에 설치된 관입 침이 노체 또는 노상의 다짐이 완료된 노면에 관입 되는 깊이를 관측하고 그 위치에 모래치환법에 의한 흙의 단위중량시험을 통하여 다짐도 값을 구하여 분석하고 연관성을 검증하는 것으로 흙의 최대허용입경이 2.36mm로 시험하였으며 $A_1$다짐의 경우는 낙하고 10cm에서 시험한 결과 값으로 추세선을 작성하고 추세선의 결정계수 $R^2=0.8677$ 값을 도출하였으며 $D_2$다짐의 경우는 낙하고 20cm에서 측정 시 결정계수 $R^2=0.9815$ 값이 관측되었다. 자유낙하시험은 낙하높이를 10cm에서 50cm까지 10cm 간격으로 변경을 하면서 시험하였다. 본 연구는 모래치환법에 의한 흙의 단위중량시험을 통하여 얻은 다짐도 값과 FFPT 시험기를 통해 얻은 관입침의 관입깊이와의 연관성을 비교 분석하여 현재의 다짐도 측정방법의 단점인 시간, 장비, 인력의 소모를 최소화하여 경제성을 확보하고 정확성과 간편성을 보장하는 다짐도 측정기 제작으로 여러 공사현장에서 다짐도 측정이 간단하게 진행될 것이다.