방사선 치료 계획 장치를 위한 의료 영상의 3차원적 자동 경계선 검출에 관한 연구 (A Study on 3Dimensional Automatic Boundaries Detection on Medical Images or Radiation Therapy Planning)

  • 최은진;서의영
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.172-175
    • /
    • 1997
  • Outline contour is detected firstly to simulate dose distribution in radiation therapy planning system. In this paper, we developed automatic contour detection system using temporal and spatial relationships of image sequences. The low level image analysis involves the use of directional gradient edge operators and Laplacian operator. The High level portion of algorithm uses a knowledge-based strategy that incorporates fuzzy resoning method.

  • PDF

Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성 (Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제16권3호
    • /
    • pp.337-345
    • /
    • 1998
  • 목적 : 전신피부의 수 mm 깊이에 한정된 피부 종양의 전신전자선조사에서 균등선량을 얻기위해, 원거리 전자선조사면에 대한 선량특성을 얻고 상하6방향조사에 의한 전신피부선량분포를 조사하였다. 대상 및 방법 : 전신조사를 위한 실험적 선량분포는 전자선 타켓-피부간 거리 300 cm에서, 크기가 105*105 $cm^2$ (콜리메-터 35*35 $m^2$, TSD 100 cm) 인 조사면으로 4 MeV 전자선의 심부선량률, 공간선량분포, 에너지감쇠에 의한 선량률 변화 등의 선량특성이 정해졌다. 환자는 상하 6방향조사가 이루어지는 동안 안정된 위치를 유지하기 위하여 양손을 치켜들고 기둥막대를 잡을 수 있는 발판에 위에 표시해둔 위치에 서게 하였다. 4 MeV 전자선 에너지를 감쇠 시켜 산란선고 피부선량을 높이기 위해 전자선 통로상 환자 전면의 20 cm 거리에 0.5 cm 두께의 산란체인 아크릴판을 설치하였다. 전신피부의 흡수선량은 테프론혼합 CaSO4:Dy 열형광소자 (1 mm 직경 * 6 mm 길이)를 전신 74 곳에 부착하여 분할조사면에 의한 합성선량을 평가하였다. 결과 : 전자선 타켓-피부간 거리 300 cm에서 얻어진 105*105 $cm^2$ 의 큰 조사면의 선량 반치폭은 130 cm 였으며, 80$\%$ 폭은 86 cm 로 나타났으며, 두 조사면을 FWHM 만큼 이동하여 두 조사면을 25 cm 띄워 조사한 합성선량분포에서 선량률이 $100\pm10\%$ 인 균등조사면의 폭은 186 cm 로 확장되었다. 인체전면 20 cm 위체에 0.5 cm 아크릴판을 삽입한 결과, 4 MeV 전자선은 최대선량점 5 mm, 80$\%$ 깊이가 7 mm, 50$\%$ 깊이는 10.7 mm를 보여 감쇠된 전자선의 평균에너지는 2.5 MeV 였다. 큰 조사면의 선속 중심에서 50 cm 떨어진 위치의 심부선량률은 중심선속의 심부선량과 거의 동일 값을 보였다. 전신피부조사에 의한 환자의 선량분포는 인체의 돌출부와 굴곡부분을 제외하고는 비교적 균등한 선량이 도달되었으며, 돌출부와 분할조사면이 잘 이루어지지 않는 중첩조사부위는 각각 30$\%$ 와 60-100$\%$ 의 과다선량이 도달되어 치료중 차폐가 불가피한 반면, 인체구조상 전자선이 가리워지는 두정부, 회음부 및 대퇴부 내측은 선량이 거의 도달 되지 않는 곳이 생겨지므로 부가적 조사가 필요함을 알 수 있었다. 결론 : 전신피부조사는 2-3 MeV의 저에너지 전자선빔에 의해 피하 수 mm 깊이에 80$\%$ 의 선량을 도달시킬 수 있으며, 높은 에너지에서는 흡수체를 이용하여 적정에너지를 얻을 수 있다. 전신피부조사에서 전신균등선량은 전자선을 상하 각각 6문조사로 고정분할 조사하는 경우 전자선이 가리워지는 부위를 제외하고 대개 $\pm10\%$ 의 선량오차범위에 들었으나, 돌출부위의 선량과다부위에는 차폐가 필요하였으며, 전자선이 가리워지는 부위는 부가치료를 통해 임상에 적합한 균등선량분포를 얻을 수 있다.

  • PDF

Estimation of Nuclear Interaction for $^{11}C$ Cancer Therapy

  • Maruyama, Koichi;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Mizuno, Hideyuki;Iseki, Yasushi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.199-201
    • /
    • 2002
  • Cancer therapy using high-energy $^{12}$ C ions is successfully under way at HIMAC, Japan. An alternative beam to $^{12}$ C is $^{11}$ C ions. The merit of $^{11}$ C over $^{12}$ C is its capability for monitoring spatial distribution of the irradiated $^{11}$ C by observing the $\beta$$^{+}$ decay with a good position resolution. One of the several problems to be solved before its use for therapy is the amount of nuclear interaction that deteriorates the dose concentration owing to the Bragg curve. Utilizing the dedicated secondary beam course for R&D studies at HIMAC, we measured the total energy loss of $^{11}$ C ions in a scintillator block that simulates the soft tissue in human bodies. In addition to the total absorption $^{11}$ C peak, non-negligible bump-shaped contribution is observed in the energy spectrum. The origin of the bump contribution can be nuclear interaction of the incident $^{11}$ C ions with hydrogen and carbon atoms. Further studies to reduce the ambiguity in dose distribution are mentioned.

  • PDF

건강검진 차량 내 흉부 방사선검사 시 공간산란선 분포 연구 (A Study on the Distribution of Scatter Ray in Chest Radiography of a Health Examination Bus)

  • 조지환;진성진;민병인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.377-383
    • /
    • 2017
  • 건강검진의 증가와 함께 검진 차량을 이용한 건강검진의 수효 또한 증가하는 추세로, 검진 차량에서의 흉부 방사선검사 시 피폭선량에 대해서도 간과할 수 없다. 실제 피사체가 있을 때 피사체의 체질량지수(BMI), 관전류량(mAs)과의 비교를 통해 산란선 발생량을 측정하여 불필요한 피폭을 최소화할 수 있는 방법을 찾고자 한다. 본 연구의 결과 대상자 BMI 전체 평균은 $23.31{\pm}3.12$으로 남자가 여자보다 BMI 값이 높게 나타났다. 전체 평균 mAs값은 $2.92{\pm}1.19$으로 남자가 여자에 비하여 높게 나타났다. 검사실 내부 위치 1의 산란선 전체 평균값은 $771.81{\pm}151.15{\mu}Sv/hr$로 나타났다. 검사실 출입문 외부 위치 2의 산란선 전체 평균값은 $53.86{\pm}25.66{\mu}Sv/hr$로 측정되었다. 이에 BMI나 mAs가 증가할수록 검사실 내부 위치 1과 외부 위치 2에서의 공간산란선량은 증가하는 것으로 나타났다. 건강검진 차량에서의 피폭선량은 거리역자승법칙을 적용하기에 매우 좁은 공간으로 공간산란선의 피폭을 최대한 줄이기 위해 방사선 관계종사자는 영상의 품질을 저해하지 않는 범위 내에서 가능한 낮은 조사조건으로 검사하고, 검사실 출입문 근처에 검사자가 대기하지 않도록 하는 노력이 필요할 것으로 생각된다.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.

전신 피부 전자선 치료(TSET)에서 EBT2 필름을 사용한 선량측정 (Dosimetry by Using EBT2 Film for Total Skin Electron Beam Therapy (TSET))

  • 황의중;라정은;정호진;안성환;김동욱;이상엽;임영경;윤명근;신동호;이세병;박성용;표홍렬;정원규
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.60-69
    • /
    • 2010
  • 전신 피부 전자선 치료(total skin electron beam therapy, TSET)를 위해서는 흔히 행해지는 일반적인 방사선 치료와 달리 치료 전 다양한 조건에서의 선량 측정과 더불어, 치료 중 지속적인 환자 신체부위별 선량 측정이 요구된다. 본 연구에서는 선형 가속기에 기반한 modified Stanford Technique으로 전신 피부 전자선 치료를 할 때 치료에 필요한 치료 전자선의 에너지와 선량의 공간적 분포 및 치료 중 환자의 각 부위별 조사선량을 EBT2 필름을 이용하여 측정 하였다. 전자선의 에너지는 이온전리함으로 측정한 값과 비교하였을 때 잘 일치하였고, 선량의 공간 분포 및 환자 각 신체부위에서의 선량 분포는 EBT2 필름을 이용하여 편리하게 측정할 수 있었다. 또한 TSET 치료중 EBT2 필름을 사용하여 in-vivo로 측정된 환자 신체 부위별 선량분포의 변화는 열형광선량계(thermoluminescent dosimeter, TLD)로 동시에 측정한 값과 비교하였을 때 잘 일치함을 알 수 있었다. 이로써 EBT2 필름의 전신 피부 전자선 치료를 위한 선량계로서의 가능성을 확인하였다.

Evaluation of absorbed dose in monkey and mouse using 18F-FDG PET and CT density information

  • Kim, Wook;Lee, Yong Jin;Park, Yong Sung;Cho, Doo-Wan;Lee, Hong-Soo;Han, Su-Cheol;Kang, Joo Hyun;Woo, Sang-Keun
    • 대한방사성의약품학회지
    • /
    • 제3권1호
    • /
    • pp.18-24
    • /
    • 2017
  • Patient-specific image-based internal dosimetry involves using the patient's individual anatomy and spatial distribution of radioactivity over time to obtain an absorbed dose calculation. Individual absorbed dose was calculated by accumulated activity multiply S-value of each organs. The aim of this study was to calculate the S-values using Monte Carlo simulation in monkey and mouse and evaluation of absorbed dose in each organ. Self-irradiation S-value of monkey heart self-irradiation was 3.15E-03 mGy-g/MBq-s, lung self-irradiation was 8.94E-04 mGy-g/MBq-s and liver self-irradiation S-value was 2.23E-03 mGy-g/MBq-s. Mouse heart self-irradiation S-value was 1.95E-01 mGy-g/MBq-s, lung was 9.59E-02 mGy-g/MBq-s, and liver was 1.40E-03 mGy-g/MBq-s. The results of this study show that the calculation protocol of image based individual absorbed dose of each organ using Monte Carlo simulation. Therefore, this study may be applied to calculate human specific absorbed dose.

쐐기필터 사용에 따른 선량증가 영역에서 선량평가 (Dose Evaluation at The Build Up Region Using by Wedge Filter)

  • 김연래;문성공;서태석;정진범;김진영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.341-348
    • /
    • 2014
  • 쐐기필터는 고선량 부분의 선량분포를 균등하게하기 위해서 사용된다. 금속쐐기필터와 기능강화 동적쐐기필터가 광자선과 상호 작용으로 표면과 선량강화영역 조사면내, 외에 선량변화를 평가하였다. 본 논문에서는 2차원적 조직등가물질로 공간 선량분포가 우수하고, 흡수선량에 따라 현상 없이 실시간으로 광학농도가 변하는 가프크로믹 EBT3 필름을 사용하여 선량평가를 실시하였다. 선형가속기 광자선 에너지는 6 MV, SSD 100 cm, 조사면 $10{\times}10cm^2$으로 고정하고 최대선량점에 400 cGy로 조사하였다. 선량분포는 열린 조사면과 $15^{\circ}$, $30^{\circ}$, 그리고 $45^{\circ}$ 금속쐐기필터와 기능강화 동적쐐기필터를 사용 하였을 때 비교 평가 하였다. $15^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 기능강화 동적쐐기필터보다 증가하였다. $30^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 기능강화 동적쐐기필터 보다 감소하였다. $45^{\circ}$ 금속쐐기필터를 사용하면 조사면내 표면선량과 선량증가영역 선량은 많은 차이로 감소하였다. 조사면 주변 반음영 영역에서는 두꺼운 방향은 증가하고 얇은 방향은 감소하였다. 선량분포를 변화하고자 하는 치료 부위에 금속쐐기필터를 적절히 사용하고 유방암 치료와 같이 표면과의 거리가 가까워지지 않으면 표면 및 선량증가영역 선량이 감소하리라 사료된다.

Relationship between Mn Nodule Abundance and Other Geological Factors in the Northeastern Pacific: Application of GIS and Probability Method

  • Ko, Young-Tak;Lee, Sa-Ro;Kim, Jong-Uk;Kim, Ki-Hyune;Jung, Mee-Sook
    • Ocean Science Journal
    • /
    • 제41권3호
    • /
    • pp.149-161
    • /
    • 2006
  • The aims of this study are 1) to construct a database using geostatistics and Geographic Information System (GIS), and 2) to derive the spatial relationships between manganese nodule abundance and other geological factors such as metal grade, slope, water depth, topography, and acoustic characteristics of the sub-bottom. Using GIS, it is possible to analyze a large amount of data efficiently, and to maximize the practical application, to increase specialization, and to enhance the accuracy of the analyses. The greater the copper and nickel grade, the higher the rating. The distribution pattern of nickel grade is similar to that of copper grade. The slopes are generally less than $3^{\circ}$ except for seamounts and cliff areas. The rating shows no correlation with slope. The rating is highest for slopes between 2.5 and $3.5^{\circ}$ in block N1 and between 4.0 and $4.5^{\circ}$ in block N3. The topography is classified into five groups: seamount, hill crest, hill slant, hill base or plain, and seafloor basin or valley. The rating proves lowest for seamount and hill crest. Our results show that the rating increases with the water depth in the study area. Nodule abundance dose not show any significant relationship with the thickness of the upper transparent layer in the study area.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.