• Title/Summary/Keyword: Spatial correlation length

Search Result 59, Processing Time 0.023 seconds

Robust Video Transmission System Employing Byte-Aligned Variable-Length Turbo Codes and Its Code-Rate Adaptation over Mobile Communication Channels (이동통신 환경에서 바이트 정렬 가변 길이 터보 코드의 적응 부호화율 적용을 통한 동영상 전송 시스템)

  • 이창우;김종원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7C
    • /
    • pp.921-930
    • /
    • 2004
  • In this paper, a robust video transmission system is proposed. To effectively prevent the corruption of video stream and its propagation in spatial and temporal domains, a version of turbo code, so-called as byte-aligned variable-length turbo code, is applied. Protection performance of the proposed turbo code is first evaluated by applying it to GOB-based variable-size ITU-T H.263+ video packets, where the protection level is statically controlled based on the joint source-channel criteria. This protection is then extended to support the adaptation of code ratio to best match the time-varying channel condition. The time-varying Rayleigh fading channel is modelled considering the correlation of the fading channel. The resulting performance comparison with the static turbo code as well as the conventional RCPC code clearly demonstrates the possibility of the proposed adaptation approach for the time-varying correlated Rayleigh-fading channel.

Relationship between Atmospheric Transmissivity and Air Pollution in Korea (우리나라의 대기투과율과 대기오염과의 관계)

  • Lee, Hyup-Hee;Kim, Young-Seop;Han, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.52-52
    • /
    • 1995
  • The temporal and spatial distribution of atmospheric transmissivity and depletion rate of solar radiation are investigated, and are compared to the concentration of several components of air pollution. The length of the data span is 11 years from 1983 to 1993. The data of radiation and sunshine rate recorded at 20 meteorological standard stations were used, and in order to investigate a relationship between the depletion rate of solar radiation and air pollution, the concentration data of air pollution observed in Seoul, Pusan, Taegu, Taejon and Kwangju were compiled from 1991 to 1993. Regression coefficient a and b vary from 0.100 to 0.209, from 0.464 to 0.691, and their means are 0.163 and 0.533, respectively. Climatological atmospheric transmissivity is ranged from 0.68 to 0.83, and its mean is 0.75. Atmospheric transmissivity is relatively low in Pusan, Taejon, Kwangju and Inchon which have large population and are highly industrialized. However, that in Chinju, Mokpo, Cheju and Sosan appears to be large compared to the aforementioned stations. Insolation rate of clear days varies from 0.71 to 0.58, and its mean is 0.63. Insolation rate of Kangnung and Chinju are higher than those of Seoul and Pusan by 5%. From the correlation coefficients between depletion rate of solar radiation and air pollution concentration, the most significant factors related to the depletion rate of solar radiation is appeared to be TSP followed by $SO_2$. Ozone shows a negative correlation, End $NO_2$ does not show a obvious correlation with the depletion rate of solar radiation.

Relationship between Atmospheric Transmissivity and Air Pollution in Korea (우리나라의 대기투과율과 대기오염과의 관계)

  • Lee, Hyup-Hee;Kim, Young-Seop;Han, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.437-446
    • /
    • 1995
  • The temporal and spatial distribution of atmospheric transmissivity and depletion rate of solar radiation are investigated, and are compared to the concentration of several components of air pollution. The length of the data span is 11 years from 1983 to 1993. The data of radiation and sunshine rate recorded at 20 meteorological standard stations were used, and in order to investigate a relationship between the depletion rate of solar radiation and air pollution, the concentration data of air pollution observed in Seoul, Pusan, Taegu, Taejon and Kwangju were compiled from 1991 to 1993. Regression coefficient a and b vary from 0.100 to 0.209, from 0.464 to 0.691, and their means are 0.163 and 0.533, respectively. Climatological atmospheric transmissivity is ranged from 0.68 to 0.83, and its mean is 0.75. Atmospheric transmissivity is relatively low in Pusan, Taejon, Kwangju and Inchon which have large population and are highly industrialized. However, that in Chinju, Mokpo, Cheju and Sosan appears to be large compared to the aforementioned stations. Insolation rate of clear days varies from 0.71 to 0.58, and its mean is 0.63. Insolation rate of Kangnung and Chinju are higher than those of Seoul and Pusan by 5%. From the correlation coefficients between depletion rate of solar radiation and air pollution concentration, the most significant factors related to the depletion rate of solar radiation is appeared to be TSP followed by $SO_2$. Ozone shows a negative correlation, End $NO_2$ does not show a obvious correlation with the depletion rate of solar radiation.

  • PDF

Chip-level NFP Calibration and Verification Using Improved Probe for NFS Standardization (NFS 표준을 위한 개선된 프로브를 이용한 칩 수준 NFP 측정값 교정 및 검증)

  • Lee, Pil-Soo;Wee, Jae-Kyung;Kim, Boo-Gyoun;Choi, Jai-Hoon;Yeo, Soon-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.25-34
    • /
    • 2012
  • New calibration method for the near-field scanning (NFS) system is presented. The proposed calibration method consisted of a new near-field antenna (NFP) and newly devised patterns as circular patch patterns (CPPs) and meander patterns (MPs). The proposed patterns were used for improving spatial resolutions and simplifying a calibration procedure of the NFP compared to the conventional method defined in the IEC61967-3 and 6. Also, the effect of the length of NFPs on attenuation characteristics was investigated with length of 8mm and 30mm. For them, we designed and fabricated CPPs of diameter (D) = 20, 40, 60, and 100mm and MPs of various widths and spaces. We found the reverse relations between spatial resolutions and heights of measuring points by using simplified calibration procedure. The testing result shows that the spatial resolution of $120{\mu}m$ at height of $200{\mu}m$ was verified without complex correlation algorithms under 8GHz. For manufacturing cost all patterns and the NFP were realized with low-cost fabrication using PCB (FR-4) not by a conventional LTCC process. For verification of chip-level EMC from the results, near-field scanning system (NFSS) having step resolution of Sub-micron scale was produced and by using the proposed NFSS and proposed NFP measurement of chip shows accurately the shape of the resolution of $200{\mu}m$ patterns for securing a high level of chip-level EMC verification.

A Comparative Analysis of Patient Visibility, Spatial Configuration and Nurse Walking Distance in Korean Intensive Care Units(ICUs) - Focused on single corridor, Pod and Composite type units

  • Ullah, Ubaid;Park, Jae Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.37-45
    • /
    • 2016
  • Purpose: The purpose of this paper is to analyze a sample of single corridor, pod type and composite type of ICUs in terms of patient visibility, spatial configurations and nurse walking distance focused on Korean cases. Methods: The measures of static visibility were used to quantify the patient visibility (upper third part of the patient bed) from the nurse station. The measure of space programme and area distribution (patient zone percentage, staff zone percentage, circulation zone percentage, corridor length per bed, distance from nurse station (NS) to patient bed and departmental gross square meter (DGSM) per patient bed) were calculated by using AutoCAD and MS Excel programs. In the second step of analysis the values of space distribution were compared among the three type of ICUs as well as the nurse walking distance, DGSM per bed and gross factor. in the third step of analysis regression analysis was conducted for the possible correlation between visibility and space programme and area distribution factors as well as nurse walking distance factors. Results: (1) It was found that on average composite type unit offer highest value of patient visibility followed by pod type, while single corridor type unit offers the minimum value of patient visibility among the three plan typologies. (2) Average patient visibility and DGSM per bed shows a strong positive correlation ($r^2=0.75$) and p=0.026. (3) Average patient visibility and average distance from NS has a strong negative correlation ($r^2=0.78$), and P=0.02. (4) On average composite type unit offer the minimum walking distance from NS (7.22 meter) followed by pod type unit (8.35 meter) and single corridor (9.76 meter). (5) Maximum distance from NS was noted in single corridor (18.19 meter) followed by pod type unit (15.14 meter) and Composite type unit (11.1 meter). Implications: This study may contribute to the visibility analysis of existing and future ICU design in Korea to achieve maximum patient visibility and reduced nurse walking distance.

Spatial Influence on Acupoints Network Derived from the Chapter on Acupuncture & Moxibustion in "Beijiqianjinyaofang" ("비급천금요방(備急千金要方)" 침구편(鍼灸篇)으로 구성한 경혈(經穴) 네트워크에 공간적 위치 변수가 미치는 영향)

  • Kim, Min-Uk;Yang, Seung-Bum;Ahn, Seong-Hoon;Sohn, In-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.29 no.3
    • /
    • pp.431-440
    • /
    • 2012
  • Objectives : Recently, network science is very popular topic in various scientific fields and many studies have reported that it gives meaningful results on studying characteristics of a complex system. In this study, based on network theory, we made acupoints network using data of combined acupoints which appeared at "Beijiqianjinyaofang". We focused to find out the distinctive roles of remote and local combinations on the network. Furthermore, we aimed to identify the possibility of numerical and quantitative application to acupuncture researches. Methods : Based on examples of combined acupoints in "Beijiqianjinyaofang", the network consisted of 291 nodes and 2,431 links. The spatial distances between combined acupoints were calculated by the human dummy model. We removed the links step by step for the three cases - remote, local, and random cases, and observed the characteristic changes by calculating path lengths, similarity indices, and clustering coefficients. Also cluster analysis was carried out. Results : The network had a small number of remote links, and a large number of local links. These two links had the distinct characteristics. Whereas the local links formed a cluster of nearby nodes, remote links played a role to increase the correlation between the clusters. Conclusions : These results suggest that acupoints network increases the connectivity between the distal part and the trunk of human body, and enables various combinations of the acupoints. This finding conclusively showed that mechanism of combined acupoints could be interpreted meaningfully by applying network theory in acupuncture researches.

Study of Correlation Between Flash Flood and GcIUH Parameters using GIS (GIS를 이용한 한계유량과 GcIUH 매개변수간의 상관성분석에 관한 연구)

  • Yang, In Tae;Park, Kheun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.4
    • /
    • pp.37-44
    • /
    • 2013
  • Concentrated localized torrential rains due to global warming and climate change have resulted in much water damage each year. GIS is used as a tool for predicting the peak-outflows caused by these regional torrential rains in mountainous rivers. However, the research of the resolution of the data is limited, and most of approaches are about hydrological geographic. This paper estimates the flood discharge needed for decision of standard rainfall of automatic rainfall warning system by using GIS with GcIUH model, and establishes the criteria of flash flood warning. It also has analyzed the terrain in river basin, extracted the morphological characteristics parameters of water shed such as stream width, channel slope, channel length, shape factor, and GcIUH parameters, and analyzed the relationship between them.

Performance Analysis of Space-Time Codes in Realistic Propagation Environments: A Moment Generating Function-Based Approach

  • Lamahewa Tharaka A.;Simon Marvin K.;Kennedy Rodney A.;Abhayapala Thushara D.
    • Journal of Communications and Networks
    • /
    • v.7 no.4
    • /
    • pp.450-461
    • /
    • 2005
  • In this paper, we derive analytical expressions for the exact pairwise error probability (PEP) of a space-time coded system operating over spatially correlated fast (constant over the duration of a symbol) and slow (constant over the length of a code word) fad­ing channels using a moment-generating function-based approach. We discuss two analytical techniques that can be used to evaluate the exact-PEPs (and therefore, approximate the average bit error probability (BEP)) in closed form. These analytical expressions are more realistic than previously published PEP expressions as they fully account for antenna spacing, antenna geometries (uniform linear array, uniform grid array, uniform circular array, etc.) and scattering models (uniform, Gaussian, Laplacian, Von-mises, etc.). Inclusion of spatial information in these expressions provides valuable insights into the physical factors determining the performance of a space-time code. Using these new PEP expressions, we investigate the effect of antenna spacing, antenna geometries and azimuth power distribution parameters (angle of arrival/departure and angular spread) on the performance of a four-state QPSK space-time trellis code proposed by Tarokh et al. for two transmit antennas.

A Study on Evaporative Characteristics of Multi-component Mixed Fuels Using Mie Scattered Light and Shadowgraph Images (Mie 산란광법 및 Shadowgraph법을 이용한 다성분 혼합연료의 증발특성연구)

  • Yoon, Jun-Kyu;Myong, Kwang-Jae;Jiro Senda;Fujimoto Hajime;Cha, Kyung-Ok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.682-691
    • /
    • 2006
  • This study was conducted to assess the effect of mixed fuel composition and mass fraction on spray inner structure in evaporating transient spray under the various ambient conditions. Spray structure and spatial distribution of liquid phase concentration are investigated using a thin laser sheet illumination technique on the multi-component mixed fuels. A pulsed Ar+ laser was used as a light source. The experiments were conducted in a constant volume vessel with optical access. Fuel was injected into the vessel with electronically controlled common rail injector. Used fuel contain $i-octane(C_8H_{18}),\;n-dodecane(C_{12}H_{26})$ and $n-hexadecane(C_{16}H_{34})$ that are selected as low-, middle- and high-boiling point fuel, respectively. Experimental conditions are 25Mpa, 42MPa, 72MPa and 112MPa in injection pressure, $5kg/m^3,\;15kg/m^3\;and\;20kg/m^3$ in ambient gas density, 400K, 500K, 600K and 700K in ambient gas temperature, 300K and 368K in fuel temperature, and different fuel mass fraction. Experimental results indicate that the more high-boiling point component, the longer the liquid phase it were closely related to fuel physical properties, but injection pressure had no effect on. And there was a high correlation between the liquid phase length and boiling temperature at 75% distillation point.

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • v.17 no.1
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.