• 제목/요약/키워드: Spark, Electrical fire

검색결과 30건 처리시간 0.034초

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 고속형 전기안전 보호장치 (Electric Safety Protection Device of High Speed for Incapable Operation of ELB and MCCB Using the Low Voltage Distribution Line)

  • 곽동걸;정도영
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1925-1929
    • /
    • 2007
  • This paper is studied on a novel Electric Safety Protection Device (ESPD) of high speed for incapable operation of Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB) using the low voltage distribution line. The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is ELB and MCCB, of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a novel ESPD of high speed to trip of distribution line on electric arc or spark due to electrical fire. Some experimental results of the proposed ESPD are confirmed to the validity of the analytical results.

고정밀 전류센서를 이용한 이중 차단용 전기화재 방재장치에 관한 연구 (A Study on Electrical Fire Disaster Prevention Device used in Double Circuit Break)

  • 박동필;곽동걸;정도영;김춘삼;신호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2102-2103
    • /
    • 2008
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a electrical fire disaster prevention device(EFDPD) for a RCD trip or a self circuit-breaking function on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 - (A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device -)

  • 곽동걸;신미영;정도영
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.71-76
    • /
    • 2006
  • 전기화재의 주된 원인은 단락 및 과부하 사고, 누전 및 접촉불량 등으로 구분되며, 화재의 발생요인은 이들 사고에서 동반되는 아크나 스파크로 인한 화재가 대다수이다. 저압배전선로에 사용되는 고감도형 누전차단기는 누전과 과부하를 검출하여 차단하는 기능은 있으나, 전기화재의 직접적인 위험요소인 아크나 스파크 현상에 대한 차단기능은 없는 것으로 분석된다. 이것은 저압 분전반에 적용되는 누전차단기의 경우 정격차단시간이 30[ms](KS C 4613)로 정해져 있어, 더욱 낮은 레벨로 주기적으로 발생되는 아크나 스파크를 감지하지 못하기 때문이다. 이러한 문제점을 개선하기 위하여 본 논문에서는 전기화재에 기인되는 아크나 스파크에 대해 누전차단기를 트립시키는 보조제어장치를 제안하고, 제안된 보조제어장치의 이론적 해석과 실험측정을 통해 그 타당성을 입증시킨다.

아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발 (Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

접속·접촉불량 사고에 의한 전기화재 방지용 보호장치에 관한 연구 (A Study on Protection Device for Electrical Fire Prevention on Joint/Contact Badness Faults)

  • 최정규;곽동걸;이승철;이봉섭;박영직
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.5-6
    • /
    • 2014
  • According to 2013 fire statistical yearbook in the National Emergency Management Agency, the main cause of an electrical fire are classified to short circuit fault, overload fault, electric leakage, partial disconnection, and joint/contact badness. The occurrence factor of fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Devices(RCDs) of high sensitivity type used at single phase (220V) cut off earth leakage and overload but the RCDs can not cut off electric arc or spark to be a main cause of electrical fire. To be improved on such problem, this thesis is proposed to a auxiliary control device for RCD cut off electric arc or spark.

  • PDF

전기화재 아크.스파크검출기 특성평가에 관한 연구 (Analysis of Characteristics of Electrical Arc Spark Detector)

  • 정용기;신효섭;지철근;김영수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.375-378
    • /
    • 2002
  • An arc/spark detector (ASD) was developed is to early detect wire failures and insecure connections that may lead to fire in residents and commercial and industrial facilities. A detailed circuit design for ASD implementation along with prototype product is reported. The tests of ASD, which were successful in phase identification, in many different arc/spark locations under different loadings, and in false alarm probability, showed the ability and capability of the state-of-the-art detector in the electric fire hazard prevention.

  • PDF

저압배선 선로의 단선사고 발생시 전기화재예방 제어장치(EFPCD)의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of EFPCD for Conductor Breaks in Low Voltage Wiring)

  • 이상호;신미영;이경호
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.103-107
    • /
    • 2004
  • 현재 저압 배선 선로에 있어서 단선 사고로 인해 발생하는 스파크와 열은 전기화재의 주요 원인이 되고 있다. 또한 단선사고 시 발생하는 전류는 일종의 써지(Surge) 전류가 되어 통신, 가전제품, 컴퓨터 그리고 각종 측정기기의 소손 및 고장을 일으키며, 특히 단선사고는 다양한 안전점검 시 발견이 매우 어려운 실정이다. 따라서, 본 논문에서는 누전차단기(Earth Leakage Breaker)의 보조 제어장치, 즉 전기화재예방 제어장치(Electrical Fire Prevention Control Device)를 개발하여, 상기 단선사고 시 누전차단기의 동작신뢰성을 제고시켜, 스파크 및 열에 의한 전기화재를 예방하고자 한다.

전기화재 예방을 위한 EFPCD동작 특성에 관한 연구 (A Study on Dynamic Characteristics of EFPCD for Electrical Fire Prevention)

  • 이상호;오홍석
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.8-11
    • /
    • 2002
  • 전기배선계통에 있어서 접속점의 접속 접촉불량과 순간단락 시 발생하는 스파크와 열축적은 절연물의 용착과 탄화현상을 발생하여 전기화재의 주요 원인이 되고 있다. 또한 접속점의 접속·접촉불량과 순간단락 시 발생하는 전류는 일종의 써지(Surge)전류가 되어 통신, 가전제품, 컴퓨터 그리고 각종 측정기기의 소손 및 고장을 일으키며, 특히 접속점의 접속·접촉불량과 순간단락은 다양한 현상을 나타내어 안전점검시 발견이 매우 어려운 실정이다. 따라서, 본 논문에서는 누전차단기(Earth Leakage Breaker)의 보조 제어장치, 즉 전기화재예방 제어장치(Electrical Fire Prevention Control Device)를 개발하여, 상기 접속점의 접속·접촉불량과 순간 단락 시 누전차단기의 동작신뢰성을 제고시켜, 스파크와 접속점의 과열에 의한 전기화재를 예방하고자 한다.

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발 (Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line)

  • 곽동걸;신미영;정도영;김효진;백성현;최병섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF