• Title/Summary/Keyword: Span-80

Search Result 255, Processing Time 0.026 seconds

The Study on the Preparation of the Silica Particles by the Reactive Crystallization (반응 결정화에 의한 실리카 미립자 합성에 관한 연구)

  • Kim, Jun Ho;Lee, Chang Hwan;Lee, Choul Ho
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.12-15
    • /
    • 2006
  • The purpose of this study was to investigate the effect of reaction conditions, solvents, and surfactants on the average size and size distribution of silica particles in preparing silica fine powders by sodium silicate. Silica fine particles were synthesized by varying kinds of solvents and surfactants using the emulsion method. Span 20, Span 40, Span 60, and Span 80 were used as nonionic surfactants, Dispersing solvents were n-Hexane, n-Heptane, iso-Octane, and n-Decane of the alkane group. In these experiments, it was known that the optimum dispersion stirring time to form the emulsion of the constant size was around 6 min. The mean sizes of silica particles, at a variety of the dispersion stirring speeds, decreased as the dispersion stirring speed increased. Also, in the case of the solvents, the size of the formed silica particles decreased when the molecular weight of the solvent increased. Lastly, in the case of the surfactants, the mean size of silica particles increased as the hydrophobic lipophilic balance (HLB) value of the surfactant decreased.

Combined Effect of Lidocaine Hydrochloride with Some Surfactants ( I ) (유화제(乳化劑)와 Lidocaine.HCl의 병용효과에 관(關)한 연구(硏究)( I ))

  • Kim, Yong-Hyoun;Yeum, Chul-Ho;Choi, Jun-Shik
    • Journal of Pharmaceutical Investigation
    • /
    • v.12 no.2
    • /
    • pp.31-36
    • /
    • 1982
  • The effect of some surfactants, such as tween 40, tween 80, span 80, and triethanolamine, on the absorption of lidocaine was studied using goldfish as a model of absorption kinetics. This model was believed that reciprocal overturn time and death time were the occurrence of biological effect versus drug absorption. The results were as follows; The threshold concentration of lidocaine was significantly reduced by the surfactants. Overturn time and death time of goldfish in the lidocaine solution were reduced by such surfactants as tween 40, tween 80, span 80 and triethanolamine, and more reduced with increasing concentration of surfactants except tween 40 and tween 80. The plots of reciprocal death time versus lidocaine concentration were linear relationship with a positive concentration intercept such as minimum effective concentration (0.2-0.8%). As results it is believed that these surfactants may form complexes with lidocaine or affect the goldfish membrane to make more permeable to lidocaine, which is adsorbed more rapidly.

  • PDF

Parameter Study for Long-Span Bridge of High-Speed Railway considering CWR Axial Force (장대레일 축력을 고려한 고속철도 특수교량의 변수별 분석)

  • Lee, Jong-Soon;Cho, Soo-Ik;Park, Man-Ho;Joo, Hwan-Joong;Nam, Hyoung-Mo
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1452-1459
    • /
    • 2010
  • Application of long-span bridge, which is affected by parameters such as span length, shoe boundary condition, track property and stiffness of superstructure and substructure etc., can vary. Especially, by CWR aspects of the axial force, that can be less constraints of construction depending on whether the application of rail expansion joint(REJ), which has disadvantaged in terms of maintenance. In this study, it was performed parameter study for multiple variables (shaft length, the upper and lower cross-section characteristics, track characteristics, etc.) in terms of CWR aspects. Structure-rail interaction analysis was applied to the typical simple span PSC Box and 3 span continuous bridge Extradosed Bridge(50m+80m+50m) excluding REJ. If you set the boundary e of variables for long-span railway bridge excluding REJ through the this study, when designing future is expected to be able to useful.

  • PDF

A Study of Fabrication and Strengthening of Plate Girder (판항교제작(鈑桁橋製作) 및 보강(補强)에 관한 연구(硏究))

  • Suh, Young Kap
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.39-51
    • /
    • 1983
  • Increasing of load on the highway bridge necessitate the strengthening of load capacity of bridge by some method. The method of strengthening is the usage of pre-stressing high tensile steel line. Having finished pre-stressing work, line is anchored both end, then it composed a member of bridge structure when loading. This paper includes the method and mechanism of strengthening of I-beam span(same originality of plate girder), could be summerized as following; (a) Simple girder, 2 span and 3 span continuous girder increasing the load capacity by more than 80 % for concentrated load. (b) For uniformly distributed load, when all span loaded, load capacity is increase more than 80% to 100% except 3 span continuous.

  • PDF

Static and Dynamic Analysis for the Optimal Relation of Rise-Span-Girder Depth in Langer Arch Bridge (랭거아치교의 라이즈-경간-형고의 최적관계를 위한 정적 및 동적해석)

  • Hur, Eun Mi;Choi, Jee Hoon;Cho, Byoung Chil;Lee, Young Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.319-327
    • /
    • 2002
  • Development of high-strength and light-weight structural steel as well as advancement in steel structure analysis enable construction of long span steel arch bridge. In an economic viewpoint, however, the design values of long span steel arch bridge needs to be optimized to reduce construction cost and achieve proper levels of structural safety. This study investigated the girder depth and the rise-span ratio for optimum design values, as well as the spectral analysis for protection against earthquake. The relationship between rise-span ratio and girder depth was derived based on the parametric studies of the basic span lengths of 60, 70, 80, 90, and 100m using a commercial Cis SAP2000. The equation relating the two variables was derived using linear regression.

The Stability of Liquid Membrane in the Extraction of the Zn Component by Liquid Surfactant Membrane Process (유화형 액막법에 의한 Zn 성분의 추출시 액막의 안정성)

  • Oh, Chi-Hoon;Hwang, Jai-Suk;Shim, Jae-Woo;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.551-559
    • /
    • 1997
  • The stability of liquid membrane in the extraction process was investigated through the extraction of the Zn component by using W/O/W emulsion type liquid surfactant membrane which was $D_2EHPA-Kerosene-Span$ $80-H_2SO_4$ system. The highest stability for liquid membrane through the Zn extraction process was obtained under the following conditions. That conditions were that span 80 concentration, as surfactant, of 2~3 vol.%;$D_2EHPA$ concentration, as extractant, of 5~7 vol.%;paraffin oil concentration, as membrane strengthening agent, of 10 vol.%;emulsion volume ratio to the external aqueous phase volume of 0.1, and internal aqueous phase volume ratio to the organic phase volume of 1.0.

  • PDF

Evaluation of Gender Effect in Various Pliers' Grip Spans for Maximum Isometric Grasping Tasks

  • Kong, Yong-Ku;Kim, Dae-Min;Park, Ji-Soo;Lee, Sung-Yong;Choi, Kyeong-Hee;Kim, Kyung Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.553-563
    • /
    • 2014
  • Objective: The purpose of this study was to evaluate the effect of gender (male, female) and grip spans (45, 50, 60, 70, 80mm) on total grip strength, resultant force, finger force and subjective discomfort rating. Background: In order to prevent musculoskeletal disorders, studies of hand tools need to be preceded based on grip strength, finger force, and subjective discomfort rating. However, experimental apparatus using tools such as pliers that reflect the actual work place was almost non-existent. Method: Fifty-Two (26 males and 26 females) participants were recruited from the student population. In this study, a pair of revised pliers, which can change grip span from 45 to 80mm was applied to estimate total grip strength, resultant force and individual finger forces. All participants were asked to exert a maximum grip force with three repetitions, and to report the subjective discomfort rating for five grip spans of pliers (45, 50, 60, 70, 80mm). Results: There were significant differences of total grip strength, resultant force, individual finger forces and subjective discomfort rating according to grip span. The lowest total grip strength was obtained from the grip span of 80mm for both genders. For resultant force, the highest resultant force was exerted at grip spans of 50, 60 and 70mm for females and 50 and 60mm for males. The lowest subjective discomfort rating was observed in the 50mm for both genders. Conclusion: Based on the result, 50mm and 60mm grip spans which provide the highest force and lowest discomfort rating might be recommendable for the male and female pliers users. Application: The findings of this study can provide guidelines on designing a hand tool to help to reduce hand-related musculoskeletal disorders and obtain better performance.

The Planning and Design of Jeong-Ji High Speed Railway Bridge (국내최장 고속철도 정지고가(L=9.3km) 교량형식 개발 및 설계 - 35m PSM PSC Box교, 80m 3경간 Arch교, 국내최초 ED교 -)

  • Jang, In-Ho;Park, Kyung-Ho;Park, Jong-Hwa;Kim, Young-Nam;Kim, Sun-Pil
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1691-1696
    • /
    • 2010
  • Jeong-Ji overbridge is designed to be 9.3km long, the longest for a high speed railway bridge ever constructed in Korea. This bridge is constituted of three types of structure. Standard type bridge is 35m PSC Box bridge which will be constructed by Precast Span Method. To cross the Cheonan Nonsan Expressway, 80m three-span steel arch bridge is designed to avoid rail expansion joint. Finally, Extradosed bridge is planned for high speed railway bridge for the first time in Korea based on originative and advanced design techniques. It is expected that this will contribute to the development of national technology for long-span high speed railway bridges.

  • PDF

Recovery of IGF-I Using Liquid Emulsion Membranes (액막법을 이용한 IGF-I 회수)

  • 최광수;문용일
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.89-94
    • /
    • 1998
  • A study was made to investigate the effects of concerning factors with IGF-I recovery on the final IGF-I concentration in the effluent and to establish recovery conditions of IGF-I using liquid emulsion membranes(LEM). D2EHPA was best carrier among Amberlite LA2, Aliquit 336 and D2EHPA for recovery rate of IGF-I. Recovery rate of IGF-I by D2EHPA volume in the oil phase was increased as increasing D2EHPA volume, and optimal volume of D2EHPA was 5% in this experiment. The recovery rate of IGF-I by D2EHPA was increased by the decreasing from pH 7 to pH 4 of external phase. Therefore, optimal pH value was 4.0. Optimal concentrations of sulfuric acid in internal phase, paraffin oil in oil phase and Span 80 for recovery rate of IGF-I were 0.1M, 2.0% and 5%, respectively, and optimal W/O rate was 2. These results suggested that optimal conditions for recovery of IGF-I were D2EHPA(5%) as carrier, pH 4.0, 0.1M sulfuric acid, 2% paraffin oil, 2.0 W/O rate and 5.0% Span 80.

  • PDF

Optimal Grip Span of A-type Pliers in a Maximum Gripping Task

  • Kong, Yong-Ku;Jung, Jin Woo;Kim, Sangmin;Jung, Heewoong;Yoo, Hakje;Kim, Dae-Min;Kang, Hyun-Sung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.511-516
    • /
    • 2013
  • Objective: The objective of this study is designing an optimal hand tool through maximum grip force study accordance to the hand grip span. Background: In order to prevent musculoskeletal diseases, studies on hand tool design are proceeding based on grip strength, finger force, and contribution of individual finger force on total grip strength. However, experimental apparatus using a tool that is actually used in work place was almost non-existent. Method: 19 males were participated in an experiment. Using the load cell inserted real plier, finger force, grip strength, and subjective discomfort rate of both hands (dominant and non-dominant) were measured in 5 different hand grip span(45mm, 50mm, 60mm, 70mm, and 80mm). Results: There was significant difference(p<0.001) of total grip strength, individual finger force and subjective discomfort rating according to various hand grip span(45, 50, 60, 70, and 80mm). Also, statistically significant different(p<0.001) was shown between the dominant hand and non-dominant hand. In addition, individual finger force in maximum grip was in order of middle finger, ring finger, index finger, and little finger. Conclusion: Optimal grip span of pliers that exerting maximum grip strength is 50~60mm. Application: This finding is expected to be used for designing proper pliers.