콘크리트 내부공극 분석을 위한 행렬간격계수 모델식의 제안 (Proposal of Matrix Spacing Factor for Analyzing Air Void System in Hardened Concrete)

  • 정원경;전인구;김용곤;이봉학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.679-682
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM is the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the matrix spacing factor by calculation of simplicity. The matrix spacing factor needs two parameters that are air content and numbers of air voids in the hardened concrete. Those are obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The matrix spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

콘크리트 공극 분석을 위한 평면간격계수의 제안 (Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete)

  • 정원경;최성용;김성환;윤경구
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

콘크리트의 공극 간격 데이터를 활용한 실측간격계수 개발 (Development of Actual Measurement Spacing Factor Using Spacing Data of Air Void in Concrete)

  • 이진범;전성일;권수안;안지환
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.701-709
    • /
    • 2011
  • 콘크리트의 공극구조를 평가하기 위한 대표적인 모델 중 하나가 Power가 제안한 간격계수(SF : spacing factor)인데, 이 PSF(power spacing factor)는 평균단일공극 개념을 사용하여 갇힌 공극의 존재 여부에 따라 그 결과값이 실제와 상이하게 나올 수 있는 단점이 있다. 이에 이 연구에서는 실측된 공극 간격 데이터를 이용하여 지수화한 AMSF(실측간격계수 : actual measurement spacing factor)를 개발하였으며, 콘크리트 혼합물의 화상 분석 결과를 이용하여 PSF와 AMSF를 비교 평가하였다. 이 연구 결과, PSF와 AMSF는 전반적으로 유사한 경향을 나타내고 있으나, PSF가 $400{\mu}m$ 이상일 때 전반적으로 AMSF가 좀 더 큰 값을 나타내고 있어, 공기량이 작은 콘크리트 혼합물의 경우 PSF는 실제보다 좀 더 작은 값으로 예측할 가능성이 있는 것으로 나타났다. 또한 갇힌 공극의 유무에 따른 PSF와 AMSF 각각을 분석한 결과, AMSF는 갇힌 공극을 포함하지 않고 분석한 값이 더 크게 나타났고, PSF는 실제와 다르게 갇힌 공극을 포함하지 않고 분석한 값이 더 작게 나타났다. 이와 같이 PSF가 이와 같은 경향을 나타내는 이유는 평균단일공극 개념을 사용하기 때문이며, 이 분석 결과를 통해 AMSF가 좀 더 실제에 가까운 분석기법임을 확인할 수 있었다.

콘크리트의 실제 공극구조 특성을 반영한 간격분포지수 제안 (Proposal of Spacing Distribution Index Reflected Actual Air Void Characteristics in Concrete)

  • 전성일;안지환;권수안;윤태영
    • 대한토목학회논문집
    • /
    • 제31권6A호
    • /
    • pp.449-456
    • /
    • 2011
  • Power에 의해 제안된 간격계수는 기하학적 모델을 바탕으로 구성된 공극 간격의 평균적 개념으로, 실제 콘크리트의 공극구조 특성을 반영하는데 한계가 있다. 이에 본 연구에서는 간격계수의 한계를 극복하기 위해 콘크리트의 실제 공극구조 특성을 반영한 간격분포지수를 제안하였으며, 간격계수와의 비교분석을 통해 이 지수에 대한 평가를 수행하였다. 본 연구결과, 간격계수는 AE제 첨가량이 증가함에 따라 감소하는 경향을 나타내었으나, 간격분포지수는 증가하는 경향을 나타내었다. 이는 간격분포지수가 간격분포곡선의 면적 값을 이용한 것으로 간격별 빈도수가 높은 것이 크게 나타나기 때문이다. 또한 간격계수 $300{\mu}m$이하의 범위에서 간격분포지수는 더 넓은 범위를 나타내었다. 이에 간격분포지수 사용 시 내구성지수 80% 이상이 되는 임계지점을 찾는데 좀 더 용이할 것으로 예상되며, 콘크리트의 내구성을 추정하는데 있어 좀 더 신뢰성 있는 분석이 가능할 것으로 판단된다. 간격분포지수는 공극 간격분포의 면적 값으로 실제 콘크리트의 공극구조특성을 반영한 지수이다. 추후, 동결융해실험 결과와의 비교를 통해 추가적인 검증연구가 필요할 것으로 판단된다.

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제14권9호
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

L형측구 콘크리트 구조물의 표면박리파손 원인분석에 관한 연구 (A Study on the Analysis of Scaling Failure Cause in L-Shoulder Concrete Structure)

  • 전성일;남정희;안상혁;안지환
    • 한국도로학회논문집
    • /
    • 제16권6호
    • /
    • pp.27-37
    • /
    • 2014
  • PURPOSES : The purpose of this study is to verify the causes of surface scaling at L-shoulder concrete structure. METHODS : From the literature reviews, mechanisms of frost damage were studied and material properties including strength, air void, spacing factor and scaling resistance of L-shoulder concrete structure were analyzed using core specimens taken by real fields. RESULTS : The spacing factor of air void has relatively high correlation of surface conditions : lower spacing factor at good surfacing condition and vice versa. If the compressive strength is high, even thought spacing factor does not reach the threshold value of reasonable durability, the surface scaling resistance shows higher value. Based on these test results, the compressive strength also provide positive effect on the surface scaling resistance. CONCLUSIONS : The main causes of surface scaling of L-shoulder could be summarized as unsuitable aid void amount and poor quality of air void structure. Secondly, although the compressive strength is not the governing factor of durability, but it shows the positive effect on the surface scaling resistance.

롤러 전압 콘크리트 포장의 공기량 및 기포간격계수와 장기 내구성의 상관관계 분석을 위한 실험적 연구 (Experimental Study on Correlation Analysis of Air-void, Air-spacing factor and Long-term Durability for Roller-compacted Concrete pavement)

  • 이준희;이승우
    • 한국도로학회논문집
    • /
    • 제18권1호
    • /
    • pp.63-72
    • /
    • 2016
  • PURPOSES : The use of roller-compacted concrete pavement (RCCP) is an environmentally friendly method of construction that utilizes the aggregate interlock effect by means of a hydration reaction and roller compacting, demonstrating a superb structural performance with a relatively small unit water content and unit cement content. However, even if an excellent structural performance was secured through a previous study, the verification research on the environmental load and long-term durability was conducted under unsatisfactory conditions. In order to secure longterm durability, the construction of an appropriate internal air-void structure is required. In this study, a method of improving the long-term durability of RCCP will be suggested by analyzing the internal air-void structure and relevant durability of roller-compacted concrete. METHODS : The method of improving the long-term durability involves measurements of the air content, air voids, and air-spacing factor in RCCP that experiences a change in terms of the kind of air-entraining agent and chemical admixture proportions. This test should be conducted on the basis of test criteria such as ASTM C 457, 672, and KS F 2456. RESULTS : Freezing, thawing, and scaling resistance tests of roller compacted concrete without a chemical admixture showed that it was weak. However, as a result of conducting air entraining (AE) with an AE agent, a large amount of air was distributed with a range of 2~3%, and an air void spacing factor ranging from 200 to $300{\mu}m$ (close to $250{\mu}m$) coming from PCA was secured. Accordingly, the freezing and thawing resistance was improved, with a relative dynamic elastic modulus of more than 80%, and the scaling resistance was improved under the appropriate AE agent content rate. CONCLUSIONS : The long-term durability of RCCP has a direct relationship with the air-void spacing factor, and it can be secured only by ensuring the air void spacing factor through air entraining with the inclusion of an AE agent.

절리 간격이 암반 사면의 안정성에 미치는 영향 (Influence of Joint Spacing to Rock Slope Stability)

  • 윤운상;권혁신;김정환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.511-518
    • /
    • 2000
  • Characteristics of joint orientation, length, spacing and their distribution are very important factors for slope stability, Especially, the effect of joint spacing is an essential factor of slope stability. This study is to analyze the effect of joint spacing in cases of sliding and toppling, which is a typical failure mode. Joint spacing can divided into vertical spacing(spacing) and horizontal spacing(gap). And then, the spacing/length ratio of joint directly affect rock slope failure. When the ratio is below 0.05, the possibility of failure is rapidly increased. In case of toppling, the possibility of failure depends on the ratio of spacing to height of slope ratio slope. As the ratio decreases, the possibility of toppling failure increased. The critical ratio of spacing to height of slope is determined by the dip angle of the slope and the orientation of joint sets.

  • PDF

볼트 간격에 따른 낙엽송 집성재 이중 볼트접합부의 전단강도 (Lateral Strength of Double-Bolt Joints to the Larix Glulam according to Bolt Spacing)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권3호
    • /
    • pp.1-8
    • /
    • 2008
  • 볼트 간격에 따른 국내산 낙엽송 집성재 이중 볼트접합부의 내력성능을 검토하기 위하여 휨 type 전단강도실험을 실시하였다. 전단시편은 강판삽입형 볼트접합부 시편으로서 볼트구멍은 볼트직경(12 mm, 16 mm), 볼트 개수(단일 볼트 : Control, 이중 볼트), 볼트 열 방향(섬유평행 : Type-A, 섬유직교 : Type-B) 그리고 볼트 간격(Type-A : 4 d, 7 d, Type-B : 3 d, 5 d)을 달리하여 제작하였다. 조건에 따른 볼트접합부의 강도성능과 파괴형상을 비교, 검토하였다. 설계표준(KBCS, 2000)시 볼트간격이 감소된 기준허용전단내력에 대한 저감계수를 산출하였다. 본 연구의 결과는 다음과 같다. 1) 단일 볼트접합부와 Type-A의 이중 볼트접합부의 볼트 한 개당 지압응력은 볼트의 직경, 볼트 간격과 비례 관계를 보여주었다. Type-B의 지압응력은 볼트의 직경이 증가할 때 감소하였고, 볼트 간격이 증가할 때 2~10% 정도 감소하였다. 2) 단일 볼트접합부와 Type-A의 이중 볼트접합부의 파괴형상은 연단거리 방향으로 할렬파단이 일어났다. Type-B의 경우 볼트간격이 3 d일 때 인장부위 볼트가 압축부위 볼트보다 더 굴곡되었고 인장부위볼트에서 할렬파단이 시작되었다. 5 d 시편의 경우 인장부위와 압축부위 볼트의 굴곡은 비슷하게 나타났으며, 압축부위볼트에서 할렬파단이 시작되었다. 3) 설계표준시 기준볼트 간격(Type A : 7 d, Type B : 5 d)에 따른 항복하중을 무차원화시켜 저감계수를 산출하였다. 12 mm 볼트접합부의 경우 Type-A인 볼트 간격 4d와 단일 볼트접합부의 저감계수는 각각 0.87, 0.55였고 Type-B인 볼트 간격 3 d와 단일 볼트접합부의 저감계수는 0.91, 0.55였다. 16 mm 볼트접합부의 경우 Type-A인 볼트 간격 4 d와 단일 볼트접합부의 저감계수는 0.96, 0.76이었고 Type-B인 볼트 간격 3 d, 단일 볼트접합부의 저감계수는 0.91, 0.77이었다.

코어 시편을 이용한 열화된 줄눈콘크리트 포장의 공극구조 분석 (Air-void Analysis of Deteriorated Jointed Concrete Pavement Using Concrete Core Specimen)

  • 최판길;정범석;윤경구;권수안
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.253-254
    • /
    • 2009
  • 본 논문은 노후화된 줄눈콘크리트 포장의 열화 원인을 평가하기 위하여 수행되었다. 콘크리트 코어 시편을 사용하여 ASTM C 457 에 의거한 화상분석(Image Analysis)실험을 실시하였다. 정화시편의 공기량, 공극구조분포 및 간격계수(Spacing Factor) 정보를 수집하고 공극구조와 관계한 내구성지수(Durability Factor)를 평가하였다. 평가결과 대부분 시험편의 간격계수가 250$\mu$m 이상으로 평가되어 동결융해에 취약한 것으로 나타났다.

  • PDF